xSoil Vapor Extraction and Air Sparging <br /> Performance Monitoring Plan <br /> Stockton Yard Maintenance Facility,Stockton <br /> Page 1-2 <br /> positive displacement vacuum blower. Soil vapor is piped from the four vapor extraction wells to the <br /> air/liquid separator. The air/liquid separator consists of a vessel which removes and stores water <br /> entrained from extracted soil vapor. The soil vapor is then treated in the oxidizer where TPH-G,and <br /> BTEX compounds are converted to CO2 and water vapor. In addition, contaminants volatilized by <br /> the AS are captured by the SVETS. The SUETS radius of influence was determined to be 35 feet (11 <br /> meters (m)) based on vacuum measurements obtained during the August 1996 soil vapor extraction <br /> pilot test performed at the site. <br /> The AS compressor is an Ingersoll Rand rotary screw Model No. XF7.5 rated at 31 cfm (878 L/min) <br /> and 100 pounds per square inch gage [(psig) (5172 mm Hg)]. It includes two oil coalescing filters. <br /> The AS radius of influence was determined to be 25 feet (7.6.m) based on pressure influence <br /> observed from the August 1996air sparge'pilot test. The compressor was sized to supply an air flow <br /> rate of approximately 5 cfm (142 L/min) per sparge injection point. Compressor accessories include <br /> an electric motor of NEMA design, electrical control switch,v-belt drive with totally enclosed drive <br /> guard, pressure switch and safety valve,mounting stand, three micron inlet particulate filter, <br /> discharge pressure gage, hour meter,mounting frame, 80-gallon (303 L) ASME-coded horizontal <br /> receiver tank,and receiver condensate drain valve. <br /> 1.3 System Controls <br /> The cause of an automatic oxidizer shutdown which results from operating conditions that exceed a <br /> programmed controller limit is displayed with a red alarm light located on the front of the oxidizer <br /> control panel. The following table lists the Processor Controlled Alarm Set Points for the King, <br /> ( Buck Technology system. <br /> 1 ' Item Low High Description <br /> TE301 600° F 316°C N/A Oxidizer Inlet Temperature <br /> TE302 N/A 1200 °F 649°C Oxidizer Exit Temperature <br /> FT101 20 scfm 566 L/min N/A Low Process Flow <br /> LS103 N/A . High Air/Liquid Separator High <br /> NIA=Not Applicable <br /> scfm=sandard cubic feet per minute <br /> AS system controls include automatic air compressor start up and shutdown switches which are <br /> activated based on receiver vessel pressure settings.The air compressor motor also has a motor <br /> overload protection switch which is activated if the motor amperage or temperature is too high, or the <br /> motor input voltage is too high or low. <br /> The AS compressor is also electrically interlocked with the oxidizer such that an oxidizer shut down <br /> (automatic or manual)will result in automatic shut down of the AS. This interlock control is designed <br /> to ensure that contaminants volatized by AS are captured and treated by the SUETS. <br /> DAPMP\Stockton Yard PMP.doc <br />