B
>
BECKMAN
>
200
>
2900 - Site Mitigation Program
>
PR0522015
>
FIELD DOCUMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2019 10:01:00 AM
Creation date
2/6/2019 9:56:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
RECORD_ID
PR0522015
PE
2950
FACILITY_ID
FA0015207
FACILITY_NAME
SJC MOSQUITO & VECTOR CONTROL DIST
STREET_NUMBER
200
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905031
CURRENT_STATUS
01
SITE_LOCATION
200 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� I � <br /> hNJ KLEINFELDER <br /> ANALYTICAL RESULTS <br /> A total of six discrete soil samples were collected and submitted for the following analyses: <br /> • Total Extractable Petroleum Hydrocarbons as referenced to Diesel and Motor Oil [TPH-D <br /> and TPH-MO] by EPA Method 8015B/DHS LUFT <br /> TPH-D and TPH-MO were none detected at or above laboratory reporting limits from five of the <br /> a six discrete confirmation soil samples collected within the excavation. Discrete soil sample C5, <br /> collected along the eastern sidewall of the excavation had TPH-MO detected at 26 mg/kg. TPH- <br /> D was none detected at this location. A summary of analytical results are included in the <br /> attached Table 1. <br /> For details refer to the chain-of-custody form and analytical results in Attachment B. <br /> CONCLUSIONS AND RECOMMENDATIONS <br /> l <br /> i <br /> • The Former UST stockpile of approximately 75 cubic yards and approximately 45 cubic <br /> E yards of overexcavated material from the steam clean sump area has been manifested and <br /> E hauled offsite to Forward Landfill of Stockton, California(See Attachment Q. <br /> i, • TPH-MO by was detected in one of the six excavation confirmation soil samples at a <br /> F' concentration of 26 mg/kg in the sump/steam clean area. Results from previous sampling in <br /> this general area are summarized in Tables 2 through 4. It is been Kleinfelder's experience <br /> j that these values would not generally trigger additional sampling or enforcement actions by <br /> regulatory enforcement agencies. Therefore Kleinfelder's does not recommend further <br /> sampling/assessment or mitigative activities related to the sump/steam clean area. <br /> • If during future grading activities additional soil discoloration or odors are noted, the <br /> signatories of this report should be contacted. <br /> A copy of this report should be forwarded to San Joaquin County Environmental Health <br /> Department (PHS/EHD) for their review and comment. <br /> This report, and the conclusions and recommendations presented in this report are subject to the <br /> "Limitations"presented below. Any party (other than SJC/MVCD or regulatory agencies having <br /> enforcement jurisdiction for this site) who would like to use this report shall notify Kleinfelder, <br /> Inc. of such intended use in writing for permission. <br /> LIMITATIONS <br /> e <br /> Kleinfelder has prepared this report in accordance with the generally accepted standards of care <br /> which exist in San Joaquin County at the time of writing. It should be recognized that definition <br /> and evaluation of geologic and chemical subsurface conditions is difficult. Judgments leading to <br /> I <br /> 42747703/ST04R882 Page 7 of 9 <br /> Copyright 2004,Kleinfelder,Inc. July 2,2004 <br />