Laserfiche WebLink
Chevron ProduLs Comp tri) 2 <br /> Chevron Service Station 49-4275 2905 Bci anon Holt i]nve Stockton,CA March 20,2000 <br /> Air Sparging System <br /> The AS system is comprised of rune AS wells (GM-1 through GM-9) and a 1 5-hp rotary <br /> vane compressor The AS system alternately infects air into wells GM-1 through GM-5 <br /> and wells GM-6 through GM-9 <br /> During the reporting period, the AS system was not operational System downtime is <br /> associated with failure of the cooling fan and air sparge blower Both the cooling fan <br /> and air sparge blower have undergone repair and were replaced on December 14, 1999 <br /> The AS system was re-started on December 14, 1999 When operational, the AS system <br /> operated at a flaw rate of 15 95 cfm and an infection pressure of 10 5 pounds per square <br /> inch Air sparge operational data, including flow rate and applied pressure data, are <br /> presented in Table 1 <br /> Dissolved oxygen (DO) concentrations were measured in site monitoring wells on <br /> December 16, 1999 and averaged 1 5 mg/L, a moderate increase from the previous <br /> quarterly data Current and historical DO concentrations are summarized in Table 2 <br /> Conclusions <br /> The SVE system will remain shutdown until water levels have dropped and exposed a <br /> sufficient length of screen in the SVE wells The AS system will continue to be operated <br /> to infect air into the groundwater and provide oxygen for biodegradation <br /> If you have any questions or require additional information, please do not hesitate to call <br /> me at (916) 364-1880 <br /> Sincerely, <br /> SECOR International Incorporated <br /> ire' c <br /> Rusty 4— <br /> Benkosky, <br /> Project Manager <br /> Attachments Table l - Air Sparge System Operational Data <br /> Table 2 - Dissolved Oxygen Well Concentrations (mg/L) <br /> Figure 1 - Site Location Map <br /> Figure 2 - Site Plan <br /> Attachment A—Remedial System Field Data Sheets <br /> cc Ms Lon Duncan, San Joaquin Environmental Health Department <br /> Mr Paul Supple, ARCO Products Company <br /> Mr Mark List, Regional Water Quality Control Board <br /> 077 41672 00119-4275 O&M 4099 Report <br />