Laserfiche WebLink
of shielding, then County variance will be sought. Variance <br /> from client and Stantec required. <br /> Pressure Overhead (station awning); Sanitary sewer 1'4" northeast of <br /> V-6(A) Over-drill Grout well column (6" deep); Product lines 3' south of well column <br /> (depth undetermined). Variance from client and Stantec <br /> require .Variance from County required. <br /> Overhead utility (unknown voltage) 7' southwest (15' high); <br /> Over-drill No will install shielding on overhead lines and install conductor <br /> V-7(A) casing to protect sewer. If overhead lines cannot be shielded, <br /> then County variance will be sought. Variance from client <br /> and Stantec required. <br /> Over-drill Pressure Sanitary sewer 1'6" northeast of well column (7" deep); tank <br /> V-8(A) Grout pit 2' south of well; Variance from client and Stantec <br /> required.Variance from County required. <br /> V Over-drill No Overhead utility (unknown voltage) 8' southwest @ 15'; had <br /> 9(A)/ overhead line removed, will have system decommissioning <br /> S-7(A) done prior to well abandonment. <br /> Subsurface electrical line to station lighting 1'6" east of well <br /> V- Over-drill No column (1' deep); Stantec will provide lock out tag out to <br /> 12(A) limit electrical shock exposure. Variance from client and <br /> Stantec required. <br /> Underground electrical line 6" north of well column (1'9" <br /> Over-drill Pressure deep) Stantec will provide lock out tag out to limit electrical <br /> S-2(A) Grout shock exposure. Variance from client and Stantec required. <br /> Variance from County required. Serious potential for <br /> electrical line to get caught onspinning augers. <br /> PressurSanitary sewer 1'9" northeast of well column (6" deep); <br /> SAW Over-drill Grout e adjacent multiple tank pits (8'). Potential product lines in <br /> play. Variance from client and Stantec required. Variance <br /> from County required. <br /> Tank Pit 6.5' north of well box; Overhead utility (unknown <br /> voltage) 9' south @ 15'&25' high; will install shielding on <br /> S 5(A) Over-drill No overhead lines and install conductor casing to protect sewer. <br /> If overhead lines cannot handle added weight of shielding, <br /> then County variance will be sought. Variance from client <br /> and Stantec required. <br /> Overhead utility(unknown voltage) 9' south @ 15'&25' high; <br /> had lower overhead line removed by utility company. Will <br /> S-6(A) Over-drill No install shielding on upper overhead line. If overhead line <br /> cannot handle added weight of shielding, then County <br /> variance will be sought. Variance from client and Stantec <br /> re uired. <br /> Well Abnormal Conditions <br /> I.D. <br /> Pressure 12.1" well casing will not fit inside 18" augers for over drill. <br /> R-1(A) Over-drill Grout Request abandonment via 10.3 sack sand slurry mixture. <br /> Variance from client and Stantec required. <br /> All of the other wells will be over-drilled.We still have a meeting with utility company to evaluate <br /> shielding request. <br />