My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
3500 - Local Oversight Program
>
PR0544111
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 12:07:10 PM
Creation date
2/7/2019 10:31:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
WORK PLANS
RECORD_ID
PR0544111
PE
3528
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
02
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A=ntec v �> <br /> No Further Action Request Report <br /> Chevron and ARCO Commingled Plume No. CP0034 <br /> April 10, 2012 <br /> SVE and AS systems were activated on January 1, 1995 and May 5, 1995, respectively. The <br /> SVE system was comprised of 14 SVE wells (V-1 through V-12 and E-6) and an Airex Katox <br /> 100 catalytic oxidizer. The SVE system was shutdown on March 1, 2001, due to low influent <br /> concentrations. Prior to shutdown, the SVE system removed approximately 4,897.2 lbs of GRO, <br /> 61.3 lbs of benzene, and 4.5 lbs of MTBE. The AS system consisted of eight AS wells (S-1 <br /> through S-6, S-8, and S-9) and a 7.5-hp blower (MD Pneumatics Model 3202). The AS system <br /> was shutdown on April 12, 2007 with the approval of SJCEHD. Historical remediation data for <br /> the SVE and AS systems are included in Appendix D. <br /> SVE Radius of Influence <br /> A radius of influence (ROI) test was performed for the SVE system operated at Chevron facility <br /> 94275 and documented in Addendum To Corrective Action Plan, submitted by Geraghty & <br /> Miller, Inc on October 9, 1997 (Table 6-1). The test involved performance of a step test of <br /> varying vacuums and measuring the induced vacuums observed in nearby wells. <br /> Documentation for a ROI test could not be found for ARCO facility 2133. To estimate a <br /> conservative value for the ROI of both the Chevron and ARCO facilities, Stantec utilized the <br /> minimum vacuum applied during the step test for Chevron facility 94275 (approximately 40 <br /> inches of water column). This applied vacuum was also observed during operation of the SVE <br /> system at ARCO facility 2133. Based on Table D-1 and Figure D-1 (Appendix D), a ROI for <br /> Chevron facility 94275 was calculated to range between 28 and 59 ft. ROI was estimated using <br /> the point at which the trend line for the induced vacuum was approximately 1% of the applied <br /> vacuum at the extraction well. Based on this evaluation, a conservative estimate of at least 25 <br /> ft ROI is assumed to have been present at ARCO facility 2133. <br /> 2.5. DISTRIBUTION OF RESIDUAL HYDROCARBONS AND OXYGENATES <br /> 2.5.1. Distribution of Hydrocarbons and Oxygenates In Soil <br /> The lateral and vertical extent of �etrolP�m hydrocarbons in soil has been delineated Historical <br /> soil analytical data shows that petroleum hydrocarbon impacts to the soil beneath the Chevron <br /> facility were mainly limited to the southern portion of the site in the vicinity of the former USTs <br /> and current and former dispenser islands. Petroleum hdrocar bon iMDacts_toJf►e soil beneath <br /> the _ARCO fac l ty._were.mainlyJimited-to-the shallow depths.iri_the_vidnity-of-the-dispenser <br /> islands in the northern port on 4f the_,slte.at�slP,nth of ar�pr�ximateLy-thr.eeJt.b_gs,_and.at.greater <br /> depths of approximately)_5_to_2Q_fLbgs in the soulhern._portion of the site to_the_south_and <br /> southwest of the USTs. Soil isoconcentration contour maps for GRO,, DRO, benzene, and <br /> MTBE at different depth intervals populated with historical soil analytical data are included as <br /> Figures 5 through 20. <br /> 94275 NFAR 2012.doc 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.