Laserfiche WebLink
Mr Chuck Carmel <br /> • March 10, 1994 <br /> Page 2 <br /> i <br /> Quarterly Sampling Field and Analytical Methods <br /> Emcon personnel measured depth-to-water, supervised purging of each well, and collected <br /> groundwater samples at the site A copy of Emcon's field notes is included in Exhibit A <br /> The purge water generated during tlus sampling event was temporarily stored on site in <br /> 55-gallon barrels then transported off site by Balch Petroleum Company <br /> All groundwater samples were analyzed for total petroleum hydrocarbons as gasoline <br /> (TPH-G) and benzene, toluene, ethylbenzene, and xylenes (BTEX) by U S Environmental <br /> Protection Agency Methods 5030/8020/DHS LUFT <br /> Quarterly Sampling Results and Discussion <br /> Emcon's field notes and the analytical report from the quarterly groundwater sampling are <br /> contained in Exhibit A Table 1 in Exhibit B presents the water-level data for this site <br /> Table 2 in Exhibit B summarizes historical groundwater flow direction and gradient data <br /> • for this site Figure 1 shows the water-level elevations for each well and the contours of <br /> equal water-level elevation for November 9, 1993 Figure 2 shows BTEX and TPH-G <br /> concentrations for each well sampled, and the approximate extent of benzene in the <br /> groundwater Table 3 in Exhibit B presents the groundwater analytical data <br /> The general groundwater flow direction is to the northeast under a hydraulic gradient of <br /> 0 003 Water-level elevations have decreased an average of 0 29 feet since the last <br /> quarterly monitoring (August 1993) <br /> The TPH-G and BTEX concentrations detected in the samples collected this quarter are <br /> generally consistent with previously reported results in wells E-3, E-b, E-S, E-9, E-10, E- <br /> 11, and BHD-1 The hydrocarbon concentrations detected in BHD-1 are thought to be <br /> attributed to the Chevron station across the street from the ARCO site Chevron's well <br /> MW-1 is located approximately 30 feet to the north of well BHD-1 and near Chevron's <br /> former underground storage tank location Samples from Chevron's MW-1 generally <br /> contain similar TPH-G and BTEX concentrations to those in BHD-1 Concentrations of <br /> BTEX and TPH-G in the samples from wells E-4 and E-5 are lower than detected in the <br /> past five sampling events The BTEX concentrations were consistent with previous results <br /> in samples collected from wells E-7 and E-12, but the TPH-G concentrations were slightly <br /> lower The samples from off-site wells PR-1, PR-2, and BHD-2 did not contain detectable <br /> concentrations of hydrocarbons, indicating that off-site migration is being contained by the <br /> . Use or disclosure of data contained on this sheet is subject to the restriction specified at the beginning of this <br /> document 03110/9A7453NRF.PORTS4THQTR RPr <br />