My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0001346
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
3500 - Local Oversight Program
>
PR0544111
>
ARCHIVED REPORTS XR0001346
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 3:33:06 PM
Creation date
2/7/2019 2:43:34 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0001346
RECORD_ID
PR0544111
PE
3528
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
02
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S E C 0 R <br /> • STANDARD PROCEDURE FOR GROUNDWATER SAMPLING <br /> Depth to Groundwater/LPH Thickness Measurements <br /> Rior to purging each of the wells, the depth to groundwater and thickness of liquid phase <br /> hydrocarbons (LPH), if present, within each well casing was measured to the nearest 0 01 foot <br /> using either an electronic Solinst water level indicator or an electronic oil-water interface probe <br /> Measurements were taken from a point of known elevation on the top of each well casing as <br /> determined in accordance with previous surveys <br /> Groundwater Monitoring Well Purging <br /> Purging was conducted prior to sampling wells that do not contain LPH, a dedicated 1-inch <br /> diameter PVC "stinger," bailer or groundwater pump was used to purge the wells Purge water <br /> was discharged directly to a vacuum truck via the "stinger', or contained on-site in 55-gallon <br /> DOT-approved drums To assure that the collected samples were representative of fresh <br /> formation water, the conductivity, temperature, and pH of the delivered effluent was monitored <br /> and recorded using a Cambridge Hydac meter or another meter similar in nature during purge <br /> operations Purge operations were determined to be sufficient once successive measurements <br /> of pH, conductivity, and temperature stabilize to within +I- 10 percent <br /> During purging a minimum of three (3) well volumes, measured as the annular space of the <br /> well casing below the groundwater surface, was removed from each well However, in the <br /> case of very slow recharging wells, purging was deemed sufficient if the well contents were <br /> • evacuated dunng purge operations Unless recharge takes more than two hours, wells were <br /> sampled once the well recharged to within in 90 percent of pre-purge groundwater elevation <br /> For very slow recharging wells (wells pumped dry during purging), samples were collected after <br /> 2 hours of recharge <br /> Groundwater Sample Acquisition and Handling <br /> Following purging operations, groundwater samples were collected from each of the wells, <br /> using pre-cleaned, single-sample polypropylene, disposable bailers The groundwater sample <br /> was discharged from the bailer to the sample container through a bottom emptying flow control <br /> valve to minimize volatilization <br /> Collected water samples were discharged directly into laboratory provided, pre-cleaned, 40 <br /> milliliter (ml) glass vials and sealed with Teflon-lined septum, screw-on lids Labels <br /> documenting sample number, well identification, collection date and time, type of sample and <br /> type of preservative (if applicable) were affixed to each sample The samples were then <br /> placed into an ice-filled cooler for delivery under chain-of-custody to a laboratory certified to <br /> perform the specified tests by the State of California Department of Health Services <br /> Environmental Laboratory Accreditation Program <br /> Containment and Disposal of Generated Water/LPH <br /> Wastewater, purge water and LPH (if present) generated during the field activities are <br /> retained on-site in appropriate containers (i a DOT-approved drums or bulk tanks) for future <br /> . disposal Wastewater is delivered under appropriate manifest to a facility certified and <br /> licensed to receive such waste streams <br />
The URL can be used to link to this page
Your browser does not support the video tag.