My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
2900 - Site Mitigation Program
>
PR0515434
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 3:40:33 PM
Creation date
2/8/2019 3:29:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE HISTORY
RECORD_ID
PR0515434
PE
2950
FACILITY_ID
FA0012144
FACILITY_NAME
ARCO STATION #6080
STREET_NUMBER
85
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
01
SITE_LOCATION
85 LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ms. Margaret Lagorio Project 797613 <br /> August 30, 1999 <br /> Page 3 <br /> remain in place, Pinnacle will direct the subcontractor to overexcavate until field <br /> screening data (using a photoionization detector [PID1) of soil samples collected from the <br /> base and sidewalls of the excavated area indicate soil containing relatively high <br /> concentrations of hydrocarbons have been removed. Overexcavation of soil will be limited <br /> to two feet laterally and six feet vertically in the product line areas and will not extend <br /> deeper than a total depth of approximately 17 feet in the UST area. The excavated soil is <br /> proposed to be stockpiled at the location shown on the site plan in Appendix A. <br /> • The anticipated length of areas to be overexcavated for product line removal and <br /> replacement will be approximately 100 to 120 feet. The actual length along the <br /> piping trenches may vary based upon observed impacts and results of field <br /> screening. <br /> • The anticipated volume of material to be removed from beneath the piping <br /> trenches is approximately 60 cubic yards. This volume is typical for recent piping <br /> and dispenser replacement activities at other ARCO facilities. <br /> • The excavated soil will be characterized for disposal and the analytical results <br /> will be evaluated to determine the appropriate, ARCO-approved, disposal <br /> facility. In the event that TPHG are less than 100 parts per million (ppm), the <br /> disposal facility may be either Redwood Landfill or BFI Vasco Road Landfill. In <br /> the event that TPHG concentrations exceed 100 ppm the soil will be transported <br /> to TPS located in Richmond, CA. Dillard Trucking, of Byron California, the <br /> ARCO transportation contractor, will submit profiling and disposal applications <br /> to the appropriate facility and transport the soil for proper disposal. <br /> • The anticipated volume of material to be removed from beneath the UST is <br /> estimated to range from approximately 300 to 800 cubic yards. This volume is <br /> typical for recent UST replacement activities at other ARCO facilities. The <br /> excavated soil from the UST location will be stored onsite and characterized for <br /> either proper disposal or, pending County approval, reuse as backfill material. <br /> • A site plan showing the piping layout and proposed locations for soil stockpile <br /> and other pertinent site features is located in Appendix A. <br /> Reporting <br /> Pinnacle will prepare a report summarizing the product delivery line, dispenser and UST <br /> removal and replacement activities, including verification soil sampling results. Copies of <br /> the certified analytical reports will be appended. <br /> CPIE:\ARCO\6080\REPORTS\608OP101,DOC-951sg:1 pilin� <br />