ogpl'.I.N SAN JOAQUIN COUNTY
<br /> �:..
<br /> ENVIRONMENTAL HEALTH DEPARTMENT
<br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232
<br /> Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd
<br /> 04(IFOR�`P
<br /> NOTICE AND ORDER TO ABATE
<br /> HOUSING AND DANGEROUS BUILDING VIOLATIONS
<br /> I
<br /> gS�a-n Joaquin County Ordinance Code, Title 8,Division 5
<br /> LOCATION: �, l,�J S 9 y.N1�� /l i 4 j S-1 0 ori I�)Cj�^ POSTING DATE: 27
<br /> CITY: S7r'/t/2114 TYPE OF PREMISE: Sr'V APN: I S-2 2 0-11 7
<br /> OWNER NAME: SLS' f Lt.9N VTW-V to PHONE:
<br /> OWNERADDRESS: ROL-( fVft�tO{Lt,� IN S CITY: SS'WGAQ�NI
<br /> TENANT NAME: PHONE:
<br /> LISTED VIOLATIONS:
<br /> Items checked below are violations of the California Health&Safety Code,State Housing Law,Section 17920.3
<br /> ❑ 1. Lack of,or improper water closet, lavatory,or bathtub or shower in a dwelling unit(subsection a.1) or per number of guest in a
<br /> hotel (subsection a.2).
<br /> ❑ 2. Lack of, or improper kitchen sink(subsection a.3).
<br /> 3. Lack of hot and cold running water to plumbing fixtures in a dwelling unit(subsection a.5)or in a hotel (subsection a.4).OW W47.r
<br /> 4. Lack of adequate heating (subsection a.6).
<br /> ❑ 5. Lack of or improper operation of required ventilating equipment(subsection a.7).
<br /> ❑ 6. Lack of minimum amounts of natural light and ventilation required by this code (subsection a.8).
<br /> ❑ 7. Room and space dimensions less than required by this code(subsection a.9).
<br /> ❑ 8. Lack of required electrical lighting(subsection a.10).
<br /> ❑ 9. Dampness of habitable rooms(subsection a.11).
<br /> ❑ 10. Infestation of insects,vermin, or rodents(subsection a.12)
<br /> ❑ 11. General dilapidation or improper maintenance (subsection a.13.).
<br /> ❑ 12. Lack of connection to required sewage disposal system (subsection a.14).
<br /> ❑ 13. Lack of adequate garbage and rubbish storage and removal facilities(subsection a.15).
<br /> ❑ 14. Other unsanitary conditions(subsection a).
<br /> ❑ 15. Deteriorated or inadequate foundations(subsection b.1).
<br /> Defective or deteriorated flooring or floor supports(subsection b.2)or of insufficient size to carry imposed loads with safety
<br /> ❑ 16. (subsection b.3).
<br /> ❑ 17. Members of walls, partitions, or other vertical supports that split, lean, list, or buckle due to defective material or deterioration
<br /> (subsection b.4)or of insufficient size to carry imposed loads with safety(subsection b.5).
<br /> ❑ 18. Members of ceilings, roofs, ceilings and roofs supports,or other horizontal members which sag, split, or buckle due to defective
<br /> material or deterioration(subsection b.6)or of insufficient size to carry imposed load with safety(subsection b.7).
<br /> ❑ 19. Fireplaces or chimneys,which list, bulge, or settle due to defective material or deterioration(subsection b.8)or of insufficient size
<br /> or strength to carry imposed loads with safety(subsection b.9).
<br /> ❑ 20. Other structural hazards(subsection b).
<br /> ❑ 21. Any nuisance(subsection c).
<br /> ❑ 22. Hazardous or inadequate wiring(subsection d).
<br /> ❑ 23. Hazardous or inadequate plumbing (subsection e).
<br /> ❑ 24. Hazardous or inadequate mechanical(subsection f).
<br /> ❑ 25. Deteriorated, crumbling, or loose plaster(subsection g.1).
<br /> ❑ 26. Deteriorated or ineffective waterproofing of exterior walls, roof,foundations, or floors, including broken windows or doors
<br /> (subsection g.2)or lack of paint or other protective covering (subsection g.3).
<br /> ❑ 27. Broken, rotted, split, or buckled exterior wall coverings or roof coverings (subsection g.4).
<br /> ❑ 28. Fire hazard (subsection h).
<br /> ❑ 29. Materials of construction are inadequate or hazardous(subsection 1).
<br /> 30. Accumulation of weeds,vegetation,junk,dead organic matter, debris, garbage, offal, rodent harborages, stagnant water,
<br /> combustible materials, and similar materials or conditions constitutes fire, health, or safety hazards(subsection j).
<br /> ❑ 31. Unsafe building due to inadequate maintenance (subsection k).
<br /> ❑ 32. Inadequate exits (subsection 1).
<br /> ❑ 33. Lack of or improper fire-resistive construction or fire-extinguishing systems or equipment(subsection m).
<br /> ❑ 34. Improper occupancy(subsection n).
<br /> ❑ 35. Inadequate structural resistance to horizontal forces (subsection o).
<br /> ❑ 36. Premise/building contains a"Lead Hazard(Section 17920.10)
<br /> ALL VIOLATIONS MUST BE CORRECTED WITHIN 30 DAYS OF NOTIFICATION - UNLESS OTHERWISE SPECIFIED BELOW
<br /> Failure to comply by the compliance date will result in the cost recovery of all EHD staff time at a rate of$122 per hour.
<br /> ❑ EMERGENCY ABATEMENT ORDER ISSUED(Section 8-5200) ❑ COMPLIANCE DATE
<br />
|