ARCHIVED REPORTS XR0011680
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BROADWAY
>
1532
>
2900 - Site Mitigation Program
>
PR0001522
>
ARCHIVED REPORTS XR0011680
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2019 3:37:29 PM
Creation date
2/11/2019 2:46:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011680
RECORD_ID
PR0001522
PE
2951
FACILITY_ID
FA0004051
FACILITY_NAME
UPS - Stockton
STREET_NUMBER
1532
Direction
N
STREET_NAME
BROADWAY
STREET_TYPE
Ave
City
Stockton
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
1532 N Broadway Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Material Safety Data Sheet No318 <br /> From Genium's Reference Collection �� XYLENE (Mixed Isomers) <br /> y Geniurn Publishing Corporation <br /> 1145 Catalvn Street (Revision D) <br /> Schenectady,NY 1303-1836 USA Issued: November 1980 <br /> GENIUM PUBLISHING CORP. Revised: <br /> (5]S]377-8855 August 1988 <br /> SECTION L MATERIAL:IDENTIFICATION :26 <br /> Material Dame: XYLENE(Mixed Isomers) <br /> Description (Origin/Uses): Used as a raw material for the production of benzoic acid,phthalic anhydride,isophthalic 3 <br /> and terephthaiic acids and their dimethyl esters in the manufacture of polyester fibers;in sterilizing catgut;with tt <br /> Canadian balsam as oil-immersion in microscopy;and as a cleaning agent in microscopic techniques. <br /> Other Designations: Dimethylbenzene;Xylol; C,H,,,; CAS No. 1330-20-7 NFPA <br /> Manufacturer: Contact your supplier or distributor. Consult the latest edition of the Chemicalweek HMIS <br /> Buyers'Guidc(Geniurn ref.73)for a list of suppliers. H 2 R 1 <br /> Comments: Although there are three different isomers of xylene(ortho,meta,and para),the health and physical F 3 I 3 <br /> hazards of all three isomers are very similar. This MSDS is written for a xylene mixture of all three isomers, R 0 <br /> which is usually commercial xylene. PPG* S 2 <br /> *See sect.8 K 3 <br /> SECTION 2. INGREDIENTS AND HAZARDS % EXPOSURE LIMITS <br /> Xylene(Mixed Isomers),CAS No. 1330-20-7* *' IDLH"' Level: I00o ppm <br /> *o-Xylene,CAS No.0095-47-6 OSHA PEL <br /> m-X}leve,CAS No. 0108-38-3 <br /> 8-Hr TWA: 100 ppm,435 mg/ml <br /> p-Xylenc,CAS No.0106-42-3 ACGIH TLVs, 1987-88 <br /> 'Check with your supplier to determine if there are additions,contarninants,or TLV-TWA:100 ppm,435 mg/ml <br /> impurities(such as benzene)that are present in reportable quantities per TLV-STEL: 150 ppm,655 mglm' <br /> 29 CFR 1910. <br /> 'Immediately dangerous to life and health. Toxicity Data'*' <br /> **** See NIOSH,RTECS(No.ZE2100000),for additional data with references Human,Inhalation,TC,:200 ppm <br /> to reproductive,irritative,and mutagenic effects. Man,Inhalation,LCL.: 10000 ppm/6 HisRat,Oral,LD.:4300 mglkg <br /> SECTION 3. PHYSICAL:DATAkol 'x <br /> Boiling Point: 275'F to 293'F(135'C to 145'C)* Water Solubility (%): insoluble <br /> Melting Point: -13'F(-25'C) Molecular Weight: 106 GramsrMole <br /> Evaporation Rate: 0.6 Relative to BuAc= 1 % Volatile by Volume: Ca 100 <br /> Specific Gravity (H.O = 1): 0.86 Vapor Pressure: 7 to 9 Torrs at 68'F(20'C) <br /> Vapor Density (Air = 1): 3.7 <br /> Appearance and Odor: A clear liquid;aromatic hydrocarbon odor. <br /> *Materials with wider and narrower boiling ranges are commercially available. <br /> SECTION 4.TIRE AND EXPL SI N DATA LOWFR . TEEM <br /> Flash Point and Method Autoignition Temperature Flammability Limits in Air <br /> 81'1=to 907(27'C to 32'C) 867-F(464-C) %by Volume 1% 7% <br /> Extinguishing Media: Use foam,dry chemical,or carbon dioxide.Use water sprays to reduce the rate of burning and to cool containers. <br /> Unusual Fire or Explosion Hazards: Xylene vapor is heavier than air and may travel a considerable distance to a low-lying source of <br /> ignition and flashback, <br /> Special Fire-fighting Procedures: Wear a self-contained breathing apparatus(SCBA)with a full facepiece operated in the pressure- <br /> demand or positive-pressure mode. <br /> SECTION 5. REACTIVITY DATA <br /> Xvicne is stable in closed containers during routine operations. It does not undergo hazardous polymerization. <br /> Chemical Incompatibilities: This material may react dangerously with strong oxidizers. <br /> Conditions to Avoid: Avoid any exposure to sources of ignition and to strong oxidizers. <br /> Hazardous Products of Decomposition: Carbon monoxide(CO)may be evolved during xylene fires. <br /> cop:,r,.t a isss cmium r•.aiur.:aL coTa.60- <br /> W <br /> f'ah, <br />
The URL can be used to link to this page
Your browser does not support the video tag.