My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BYRON
>
0
>
2900 - Site Mitigation Program
>
PR0517323
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2019 3:46:08 PM
Creation date
2/14/2019 9:40:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0517323
PE
2960
FACILITY_ID
FA0013339
FACILITY_NAME
MT HOUSE SITES 1-6
STREET_NUMBER
0
STREET_NAME
BYRON
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
BYRON RD
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2890
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M. Scott Mansholt -3 - 8 March 2005 <br /> ChevronTexaco <br /> Mountain House # 1 <br /> pipelines ROW, and the railroad tracks. Vertically, soil and groundwater impacts are defined by non <br /> detect for TPH compounds in samples obtained at 48 feet from boring MH1-1. <br /> A well survey for domestic wells within one-half mile of the project revealed that three private wells <br /> were identified cross-gradient to the site, two are southeast and one is northwest. Review of Department <br /> of Water Resources well completion records indicate that the three wells were completed with at least a <br /> 35 to 50-foot sanitary surface seal, These surface seals extend below the shallow groundwater(occurs <br /> approximately 12 to 18 feet) that occurs at this site. Considering the depths of the sanitary seals coupled <br /> with the distance from the project site, dissolved petroleum constituents likely will not affect these <br /> domestic wells. <br /> Consequently, review of the reports indicates that the extent of impacted soil and groundwater has been <br /> adequately delineated. Removal of impacted soil containing elevated concentrations of hydrocarbons <br /> may not be feasible given that the majority lies beneath the railroad, Byron Road, a portion of Mountain <br /> House Creek, including the new bridge at the Mountain House# 1 project site. We concur that <br /> additional work is not needed at this time. <br /> Previously, Regional Board staff concurred with a plan to evaluate and recommend remedial options for <br /> accelerating product removal and/or removal of impacted soils at ChevronTexaco's Minnesota Avenue <br /> OVP site. The findings and recommendations are to be submitted by 1 April 2005 for review by <br /> Regional Board staff. Following review of the findings, further investigations and/or remediation <br /> options may be evaluated for Mountain House Site# 1. <br /> Regional Board staff cannot make any final determinations until a human health risk assessment has <br /> been conducted. Based on the assessment, additional borings, samples, installation of monitoring wells <br /> with implementation of a groundwater monitoring plan could be needed. <br /> If you have any questions or comments, please contact Dean Hubbard at (559) 445-5179. <br /> �4( <br /> 4: ) <br /> SHELTON R. GRAY C. DEAN HUBBARD <br /> Senior Engineering Geologist Engineering Geologist <br /> RG No. 6357 <br /> cc: Michael Inf ima, San Joaquin County EHD, Stockton <br /> Luis Mercado, SAIL, Sacramento <br /> SLIC/ElChevronTexaco/Mountain House#1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.