Laserfiche WebLink
�f <br /> 11 <br /> analysis for TPHg, BTEX, and oxygenates. <br /> REPORT OF FINDINGS FOR THE EXTRACTION WELL PUMP TEST <br /> Procedure <br /> The influence of the EW-1 was tested on June 25,2004. EW-1 was pumped for 7 hours. The initial <br /> flow rate was 17.8gpm,decreasing to 14gpm over the 7 hour period. EW-1 is constructed of 6"PVC <br /> well casing in a 15" augured hole with filter pack. The depth of the well is 60' below the ground. <br /> The water level is 33' below the ground. <br /> The log of borings indicate that the depth of the aquifer is about 53' from the ground surface. The <br /> depth of the aquifer is bounded by the free surface of the water at the top and the layer of silts and <br /> clays at the bottom, making the aquifer 20' thick. EW-1 is a fully penetrating well. <br /> The monitoring wells are 2"PVC casings and vary in depth from 55'to 64.33'. All monitoring wells <br /> are considered fully penetrating. <br /> The submersible pump was a Grunfos SQ/SQE 180. The flow was tuned with a PVC gate valve and <br /> the flow was measured with a 314" flow meter. The contaminated water was pumped through a <br /> single pass activated carbon filter that removed the old gasoline and the treated water was stored in <br /> one batch in a 21,000gal Rain for Rent tank on the property. The water in the tank will be tested and <br /> disposed of through a city sewer discharge permit. The barrels from previous testing and well <br /> purging were also pumped through the filters in order to treat and dispose of the 18 accumulated <br /> barrels. <br /> Depth to ground water data was collected throughout the pumping period and the time interval was <br /> noted for each measurement. The time interval for the flows were also noted. The results were <br /> analyzed with the AQTESOLV computer program using the Theis confined Aquifer model. The <br /> assigned parameters were b= aquifer thickness of 20ft, Kz/Ki= ratio of vertical permeability to <br /> horizontal permeability of .5, and that the extraction well and the monitoring wells were fully <br /> penetrating. <br /> Findings <br /> The cone of influence for the 7 hour pump test is as follows: <br /> WELL # DISPLACEMENT ft RADIUS ft <br /> MW-1 1.15 23.33 <br /> MW-2 3.27 41 <br /> MW-3 1.35 64.78 <br /> MW-7S .45 88 <br /> MW-8S .25 143.4 <br /> From the computer analysis the Transmissivity is estimated at 0.3621 ft2/min,the Storage coefficient <br /> is 0.005304, and the thickness of the aquifer is 20'. <br /> • <br /> From the outlet of the filter,the treated water analysis was non-detect for all BTEX compounds and <br /> 4 <br />