SOxygenates except Xylene was 1.1 ppb. <br /> Conclusions <br /> The extraction well has influence with all areas that are contaminated and has the ability to remove <br /> the plume. The filter has the ability to treat the ground water to E.P.A.drinking water levels. <br /> Recommendations <br /> It is recommended that the EW-1 be used to remove the plume. It is also recommend that a two <br /> stage activated carbon filter be used to treat the ground water instead of the single pass filter used <br /> in the test. It is important to note that the influence area is directly related to the flow of the <br /> extraction well. The well is capable of sustaining 14 gpm. The test data indicates that 14gpm is <br /> required to provide influence at MW-8S. Currently the city sewer operator is allowing discharges <br /> of only 10 gpm, which may not be enough to provide influence to MW-8S, and could require a <br /> second extraction well to influence that area. <br /> Please contact Mike Vlach at(916) 729-5184 if you have any questions on this report. <br /> Respectfully submitted, <br /> Foothill Engineerin pFES 10 q <br /> C 57707 <br /> Mike Vlach, PE EXP.12-31-45 <br /> sT CIV1 /1y <br /> Attachments:Groundwater Groundwater clysis Recap,Site Maps,Del-Tech Monitoring Report,Lab Reports, <br /> Pump Test Print Outs <br /> cc: Michael D. & Sharon Olivarez, 436 W. Scotts Ave. Stockton, Ca. 95203 <br /> • <br /> 5 <br />