Laserfiche WebLink
Table 2 <br /> SVE Test Monitoring Data <br /> ARCO Station 2186, 3212 North California Street, Stockton,California <br /> Influent au from well VW-1S on 9118100 Observation wells <br /> Time Extraction Extracted Applied Field Air Sample Air Sample Results Elapsed VW-2S VW-3S <br /> Flow rate air flow vacuum PID tD# TPHG Benzene time <br /> fpm scfm "WC ppmv mg/m3 mg/m3 min <br /> 930AM 115 1001 180 000 075 025 <br /> 10 00 AM 110 957 100 239 0 30 085 035 <br /> 10 30 AM 109 948 100 190 VW 1 Inf(1045) 3780 591 100 085 036 <br /> 1100 AM 109 948 100 253 130 090 037 <br /> 1130 AM 113 9 83 100 858 200 095 0 39 <br /> 12 00 PM 113 9 83 100 1009 230 0 95 0 4 <br /> 12 30 PM 115 1001 100 1004 300 0 95 04 <br /> 100 PM 109 948 100 882 VW-1A Inf(1300) 4320 762 330 100 0 4 <br /> 130 PM 115 1001 100 938 400 100 0 4 <br /> Distance from extraction well VW-1 (ft) VW-1S 34 52 <br /> Screen Interval(ft BGS) 22 2-36 3 221-360 22-36 <br /> Depth-to-water(DTW)(ft BGS) 3627 362 4035 <br /> Available screen interval above water table(ft) 1407 141 1835 <br /> Notes <br /> scfm-standard cubic feet per minute at 1 atmosphere and 70 degree Fahrenheit ft-feet <br /> "of WC-applied and induced vacuum in inches of water column ppmv-parts per million by volume <br /> mg1m3-milligram per cubic meter PID-Photoionization detector <br /> TPHG-total petroleum hydrocarbons as gasoline DTW-depth to water <br /> BGS-below ground surface <br /> Tb12 xis Pagel of 1 DELTA � <br />