Laserfiche WebLink
Table 3 <br /> SVE Test Monitoring Data for Well VW-2S <br /> ARCO Station 2186, 3212 North California Street, Stockton, California <br /> Influent air from well VW-2S on 9119100 Observation wells <br /> Time Extraction Extracted Applied Field Air Sample Air Sample Results Elapsed VW-1S VW-3S <br /> Flow rate air flow vacuum PID ID# TPHG Benzene time <br /> fpm scfm "WC ppmv mg/m3 mg/m3 min <br /> 7 00 AM 124 1079 80 214 000 070 065 <br /> 7 30 AM 114 992 80 835 030 075 072 <br /> 8 00 AM 111 966 80 735 100 0 80 072 <br /> 8 30 AM 109 948 80 889 130 080 073 <br /> 9 00 AM 112 974 80 677 VW-2A Inf 2,740 332 200 085 073 <br /> 9 30 AM 111 966 80 754 230 085 074 <br /> 10 00 AM 111 9 66 80 693 300 085 076 <br /> 10 30 AM 117 1018 80 678 330 0 85 076 <br /> 11 00 AM 112 974 80 572 400 085 076 <br /> Distance from extraction well VW-2(ft) VW-23 34 38 <br /> Screen Interval(ft BGS) 221-36 22 2-36 3 22-36 <br /> Depth-to-water(DTW)(ft BGS) 362 3627 4035 <br /> Available screen interval above water table(ft) 141 1407 1835 <br /> Notes <br /> scfm-standard cubic feet per minute at 1 atmosphere and 70 degree Fahrenheit ft-feet <br /> "of WC-applied and induced vacuum in inches of water column ppmv-parts per million by volume <br /> mg/m3-milligram per cubic meter PID-Photoionizatlon detector <br /> TPHG-total petroleum hydrocarbons as gasoline DTW-depth to water <br /> BGS-below ground surface <br /> I <br /> Tb12 As Page 1 of 1 DELTA <br />