My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000660
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000660
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 7:20:55 PM
Creation date
2/15/2019 3:12:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000660
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFinal Remediation Plan <br /> • FLAG CITY CHEVRON <br /> I6421 Capitol Avenue, Lodi, California <br /> I1.0. INTRODUCTION <br /> At the request of Mr Richard Bokides of the Bokides Family Limited Partnership, Advanced <br /> GeoEnvironumental, Inc (AGE) has prepared thus Final Remediation Plan(FRP) for 6421 Capitol <br /> Avenue, Lodi, California(the site) The site setting is illustrated on Figure 1 Site structures and well <br /> Ilocations are depicted on Figure 2 <br /> The purpose of this FRP is to detail the design, installation and operation of an on-site ground water <br /> extraction and treatment system Ground water remediation(pump and treat) will consist of ground <br /> water extraction in conjunction with treatment utilizing granulated activated charcoal (GAC), <br /> MTBE-hydroscopic synthesized filter media technology The FRP is prepared as required by <br /> I California Regional Water Quality Control Board-Central Valley Region (RWQCB) Cleanup and <br /> Abatement Order No 5-00-700, dated 01 March 2000 and is in accordance with RWQCB guidelines <br /> Appendix A Reports Tri-Regional Board Staff Recommendations for Preliminary Investigation and <br /> Evaluation of Underground Tank Sites <br /> S2.0. BACKGROUND <br /> The site is located at the northeast intersection of Capitol Avenue and Thornton Road, approximately <br /> 500 feet south of California State Highway 12 and approximately 5 miles west of Lodi, California <br /> (Figure 1) The site is located in the northeast quarter of Section 14, Township 3 North, Range 5 <br /> East, Mount Diablo Base and Meridian (Teminous Quadrangle, 7 5-Minute USGS Topographic <br /> Series, 1978, photo revised 1993) <br /> 21 SITE DESCRIPTION <br /> The property is currently utilized as a Chevron fueling facility and mini-market The site consists of <br /> one building structure, six fuel dispensers,three 12,000-gallon gasoline USTs and one 12,000-gallon <br /> diesel UST (Figure 2) Soil and ground water on the site has been impacted by petroleum <br /> hydrocarbons as the result of an unauthorized release from a UST formerly located on the site <br /> 2 2 PREVIOUS INVESTIGATION <br /> The following is a summary of previous investigation at the site as the result an unauthorized release <br /> of fuel products to the subsurface <br /> • 02& 03 May 1991-AGE was informed by the San Joaquin County Public Health Services - <br /> Advanced GeoEnvironmeutai,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.