15 January 2002 <br /> • AGE-NC Project No 96-0232 <br /> IPage 12 of 16 <br /> I The results from the ground water monitoring and sampling events performed in December 2001 are <br /> as follows <br /> • Generally, depth to ground water at the site vaned between 14 and 17 feet bsg <br /> • First Zone ground water flow direction at the site appeared to be oriented toward the area of <br /> MW-i and MW-2 radially Inward from all directions at an approximate gradient of 0 002 <br /> f1/ft or less (Figure 3) Outside the area of Influence of MW-1, First Zone ground water flow <br /> direction was inferred east at an approximate gradient of 0 001 or less <br /> Second Zone ground water flow direction was Inferred to be generally toward the east- <br /> southeast at an approximate gradient of 0 002 f1/ft or less (Figure 4) <br /> • Secondary Aquifer Zone ground water flow direction was Inferred to be generally toward the <br /> east-southeast at an approximate gradient of 0 001 ft/ft or less (Figure 5) <br /> I Primary Aquifer Zone ground water flow direction was inferred to be generally toward the <br /> east-southeast at an approximate gradient of 0 002 ft/ft or less (Figure 6) <br /> • First Zone and possibly Second Zone ground water flow direction and gradient during the <br />�. Flag City Chevron monitoring event appeared to be influenced by the remedial ground water <br /> extraction <br /> • Due to the low ground water gradient at the site, small variations In ground water <br /> measurements or changes of recharge/discharge of the local ground water could greatly <br /> modify the Inferred ground water flow direction <br />' • Increasing ground water elevations were reported at the site between September 2001 and <br /> December 2001 monitoring events Hydrographs depicting recorded ground water elevations <br />' at wells MW-2, MW-6A and MW-6B vs time are in Appendix I <br /> • On-site, the greatest concentration of dissolved MTBE was detected in the sample collected <br /> from First Zone extraction well EW-4 at a concentration of 53 ug/1 (Figure 8), low <br />' concentrations of on-site MTBE were detected in water samples from First Zone extraction <br /> wells EW-5,EW-6,EW-8,EW-9,EW-10, and from Second Zone monitoring well MW-9A, <br />' (Table 6, Figure 9) <br /> • Off-site,the greatest concentration of MTBE was detected in Rocky's Upper Zone water near <br /> the Rocky's Restaurant domestic water well in MW-1 IB at a concentration of 120µg11, in <br />' First Zone water from Flag City Chevron monitoring well MW-7 at a concentration of 42 <br /> yg/l, and in Three B's Truck Plaza monitoring well MW-4 at a concentration of 80 gg/l <br /> (Figure 7) Low concentrations of off-site MTBE were detected in First Zone water in <br />' samples collected from wells MW-12A, MW-13A, Three B's Truck Plaza monitoring wells <br /> MW-1, MW-2 and MW-6, Second Zone water from well MW-11A and Primary Aquifer <br /> water from well MW-11 D (Table 6, Figures 10 and 11) <br /> Advanced GeoEnvironmental,Inc <br />