My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000691
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000691
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 9:31:54 PM
Creation date
2/15/2019 4:11:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000691
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
01 May 2000 r <br /> AGE-NC Project No 96-0232 <br /> Page 4 of 11 <br /> 32 SOIL-GAS AIR SAMPLE COLLECTION <br /> _ x , <br /> Soil-gas air samples were collected utilizing a Geoprobe soil-gas air sampling assembly, the <br /> assembly consisted of an expendable vapor point attached to the bottom of 1-inch diameter hollow, <br /> drive rods The assembly was advanced to the target depth (5 feet bsg) and was retracted upward <br />' approximately six inches to expose the desired strata, soil-gas air samples were extracted by r <br /> lowering a 'sampling tube through the center of the hollow drive cods to the desired depth and <br /> threading into the expendable point holder <br /> At the surface, the polyethylene tubing was attached to a vacuum pump The vacuum'pr mp applied <br /> _a negative pressure to the exposed soil column until an estimated three tubing-volume's of soil gas - <br /> I and/or ambient air was evacuated through the sampling system Aftei purging the system, a Tedlar <br /> bag was placed into a vacuum chamber and attached directly to the sampling tube tluough-a <br /> collapsible, air tight port A negate e pressure was applied to the vacuum chamber with the vacuum <br /> Ipump, expanding the Tedlar bag, allowing the sample to enter directly into the Tedlar bag <br /> Following sample collection, the samples were placed rn a covered container and transported under <br /> chain-of-custody to Precision Enviro=Tech Analytical Laboratory (PEAL), a DHS-certified <br /> laboratory in Stockton, California Each sample was,analyzed within 72 hours of collection for TPH- <br /> g, BTEX and MTBE in accordance with EPA Method TO-14 <br /> ' s <br /> 3 3 EQUIPMENT DECONTAMINATION <br /> Prior to sample collection, Geoprobe soil sampling equipment was thoroughly rinsed with clean <br /> water after washing with a solution of-Alconox Geoprobe rods were thoroughly cleaned prior to soil <br /> probe boring advancement <br /> t <br /> 34 ANALYTICAL RESULTS OF SOIL-GAS AIR SAMPLES <br /> A total of seven soil-gas air samples were submitted for laboratory analysts TPH-a, benzene and ' <br /> MTBE were detected in the soil-gas air sample collected fronn P-6 at concentrations of 600 ,ug/l, 0 5 <br /> ,ug/l and'2 5 4g11, respectively none of the analytes were detected to any other soil-gas an samples <br /> Analytical results of soil gas samples are summarized in Table 1 The laboratory report (Precision <br /> Enviro-Tech Analytical Laboratory Sample I D 's,AG31500-01 through'07) and,chann-of-custody <br /> forms are presented in Appendix E <br /> , r r <br /> Adsanccd GcoEnr ironwcntal Inc <br /> " <br />
The URL can be used to link to this page
Your browser does not support the video tag.