Laserfiche WebLink
two samples at concentrations that were greater than the reporting limit, but less than five times <br /> the blank concentration, and were qualified as estimated (J) in all four samples. <br /> • Equipment Rinse and Field Blank, collected on May 2, 2012, were associated with the analysis <br /> of six samples and had TDS detected at 5.0 and 7.0 mg/L, respectively, and TOC detected at 0.2 <br /> and 0.1 mg/L, respectively. Additionally, sulfate was detected at 1.1 mg/L in Equipment Rinse. <br /> Sulfate and TDS were detected in the associated samples at concentrations that were greater <br /> than five times the blank concentration and were not qualified. TOC was detected in five samples <br /> at concentrations that were below the reporting limit and less than five times the blank <br /> concentration; these results were qualified as estimated non-detects (U) at the reporting limit. <br /> All data submitted for this project are of known and acceptable quality as qualified, based on laboratory- <br /> established control limits and the data quality objectives. These data are considered acceptable for their <br /> intended purposes. <br /> Summary of Qualified Data: <br /> Sample Name Laboratory Sample Parameter Result Unit Qualifier <br /> ID Date <br /> EW-1 Y2D2412-01 4/24/2012 TOC 1.3 m /L J <br /> MW-213 Dup Y2D2412-14 4/24/2012 Hexavalent chromium 5130 /L J <br /> MW-214 1-8 Y2D2412-15 4/24/2012 Hexavalent chromium <0.20 /L UJ <br /> MW-310 Y2D2412-16 4/24/2012 Hexavalent chromium 8.36 /L J <br /> MW-325 Y2D2412-17 4/24/2012 Hexavalent chromium 7.82 pg/L J <br /> MW-320 Y2D2412-18 4/24/2012 Hexavalent chromium 10.9 /L J <br /> MW-320 Dup Y2D2412-19 4/24/2012 Hexavalent chromium 10.9 /L J <br /> Field Blank Y2D2412-20 4/24/2012 Hexavalent chromium <0.20 /L UJ <br /> Equipment Rinse Y2D2412-21 4/24/2012 Hexavalent chromium <0.20 /L UJ <br /> TW-12 Y2D2510-05 4/25/2012 TOC 1.7 m /L J <br /> TW-13 Y2D2510-06 4/25/2012 TOC 1.8 m /L J <br /> TW-16 Y2D2510-07 4/25/2012 TOC 1.1 m /L J <br /> TW-17 Y2D2510-08 4/25/2012 TOC 2.0 m /L J <br /> MW-303 Y2D2510-09 4/25/2012 Chromium 0.005 m /L J <br /> MW-304 Y2D2605-01 4/26/2012 Hexavalent chromium 8.27 /L J <br /> MW-6 Y2D2605-02 4/26/2012 Hexavalent chromium <0.20 N /L UJ <br /> MW-322 Y2D2605-03 4/26/2012 Hexavalent chromium 17.4 /L J <br /> MW-105 Y2D2605-04 4/26/2012 Hexavalent chromium <0.20 /L UJ <br /> Field Blank Y2D2605-05 4/26/2012 Hexavalent chromium <0.20 /L UJ <br /> Equipment Rinse Y2D2605-06 4/26/2012 Hexavalent chromium <0.20 /L UJ <br /> MW-201 Y2D3003-01 4/30/2012 Hexavalent chromium 10.7 /L J <br /> MW-2 Y2D3003-02 4/30/2012 Hexavalent chromium 15.9 /L J <br /> MW-2 Y2D3003-02 4/30/2012 Sulfate 29.9 m /L J <br /> MW-207 Y2D3003-03 4/30/2012 Hexavalent chromium 56.3 /L J <br /> MW-301 Y2D3003-04 4/30/2012 Hexavalent chromium 59.6 /L J <br /> MW-301 Dup Y2D3003-05 4/30/2012 Hexavalent chromium 59.0 /L J <br /> Page 3 of 6 <br />