ARCO Products Company 3 <br /> ARCO Service Station#4493,205 North Center Street.Stockton,CA July 7,1999 <br /> compound) by EPA Method 8015/8020 and fuel oxygenates and <br /> volatile organic compounds by EPA Method 8260A. Additionally, <br /> one sample from each boring was analyzed for lead by EPA 6010a. <br /> TPH-g had reported concentrations of 1.80 mg/kg and 1.56 mg/kg in <br /> soil samples MW-4@20'and MW-4@25', respectively. Benzene had a <br /> maximum concentration of 0.118 mg/kg (MW-4@25'). MtBE had <br /> reported concentrations of 0.345 mg/kg (MW-3@25') and 1.52 mg/kg <br /> (MW-4@25'). Lead had reported concentrations of 12.3 mg/kg and <br /> 141 mg/kg in soil samples MW-1 @ 10'and MW-2@ 10', respectively. <br /> TCE and PCE were reported as nondetect. Soil analytical results are <br /> presented in Table 1. Field and laboratory procedures are presented as <br /> Attachment C. Certified analytical reports and chain-of-custody <br /> documentation are presented as Attachment D. <br /> • Groundwater Monitoring Well Development, Sampling, and <br /> Surveying. After installation, the groundwater monitoring wells were <br /> developed by rigorously surging over the length of the screen interval <br /> and by purging ten casing volumes of water. <br /> Groundwater samples were collected from the newly installed <br /> groundwater monitoring wells on February 16, 1999. Groundwater <br /> samples were analyzed for TPH-g and BTEX by EPA Method <br /> 8015/8020 and fuel oxygenates and volatile organic compounds by <br /> EPA Method 8260A. TPH-g was reported in two wells at <br /> concentrations of 231 ppb (MW-1) and 15,000 ppb (MW-4). Benzene <br /> was reported in two wells at concentrations of 1.35 ppb (MW-1) and <br /> 503 ppb (MW-4). MtBE was reported in monitoring wells MW-3 and <br /> MW-4 at concentrations of 7.06 ppb and 9,990 ppb, respectively. <br /> TBA, TAME, DIPE, and EtBE were reported as nondetect in all <br /> wells. TCE was reported in three wells at a maximum concentration <br /> of 433 ppb. PCE was reported in well MW-2 at 2.50 ppb. <br /> Groundwater analytical data is presented in Table 2 and is shown on <br /> Figure 2. Field and laboratory procedures are presented as <br /> Attachment B. Groundwater sampling parameters are included on the <br /> field sheets in Attachment E. <br /> The wells were surveyed to mean sea level by Morrow Surveying, a <br /> licensed surveyor. Attachment F contains the surveyor's site plan <br /> showing the locations and elevations of the wells. <br /> • Groundwater Flow Direction. Depth to groundwater at the site <br /> ranged from 13.35 feet bgs to 14.64 feet bgs. Based on monitoring <br /> data collected on February 16, 1999, groundwater flow was to the <br /> east-northeast at 0.008 ft/ft and is shown on Figure 3. <br /> 76600-022-02/well install <br />