My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:59:08 PM
Creation date
2/26/2019 11:59:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL. 3 Y 201J <br /> SWRCB,January 2002 Page of <br /> NVIRONMENTA <br /> 4. TANK ANNULAR TESTING __ <br /> Test Method Developed By: O Tank Manufacturer ❑Industry Standard E Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: 9 Pressure O Vacuum ❑Hydrostatic <br /> ❑Other(S ec6) <br /> Test Equipment Used: Vacuum pump/gauge Equipment.Resolution: 0. 50"Hg <br /> Tank# 87Syphon Tank#87Master TankA87Slave Tank# 91 <br /> Is Tank Exempt From Testing?' O Yes k]No O Yes R]No O Yes X]No O Yes 2 No <br /> Tank Capacity: 9,490 9, 490 9,490 9,490 <br /> Tank Material: FRP FRP FRP FRP <br /> Tank Manufacturer: Xerxes Xerxes Xerxes Xerxes <br /> Product Stored: Unleaded Unleaded Unleaded Premium <br /> Wait time between applying <br /> 1 Omin n 10mi n 1 0 mi n 1 0 m i n <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: 9 : 55am 10:15am 10: 35am 11 :00am <br /> Initial Reading N): 1 0"Hg 1 0"Hg 1011 1 0"Hg <br /> Test End Time: 10: 5 5 am 11 :1 5 am 1 1 :3 5 am 12:0 0 pm <br /> Final Reading(Rp): 1 0"Hg 1 0"Hg 1 0"Hg 10"Hg <br /> Test Duration: 1 h r 1 h r 1 h r 1 hr <br /> Change in Reading(RF-R): 0 .0"Hg 0 .0"Hg 0.0"Hg 0.0"Hg <br /> Pass/Fail Threshold or Criteria: ±0 . 0"Hg ±0.0"Hg ±0.0"Hq ±0.0"Hg <br /> Test Result•• Z Pass O Fail 9 Pass O Fail t] Pass ❑Fail 5a Pass ❑Fail <br /> Was sensor removed for testing. O Yes 1ANo DNA Dyes ballo DNA ❑Yes k No O NA ❑Yes j1 No DNA <br /> Was sensor properly replaced and XYes O No ❑NA ayes ❑No O NA mYes U No ❑NA 9 Yes BNo ❑NA <br /> verified functional after testing? <br /> Comments (include infunwdion on repairs made prior to testing and recommended follow-up for failed tests) <br /> ' Secondary containment systems where the cobtinuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.