COMPLIANCE INFO 2010 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:59:08 PM
Creation date
2/26/2019 11:59:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JUL 31 2015 <br /> SWRCB,January 2002 �NVIRONMENT'A! Page of <br /> 8. FILL RISER CONTAINMENT.7U-1 IC IES7ING <br /> Facifity is Not Equipped With Fill Riser Containment Sums J <br /> Fill Riser Containment Sumps are Present,but were Not Tested C) <br /> Tcs!Mcthcd De ol-rod By: D Q . ind._.—..., Q+_=.J—A <br /> Other(Specby) <br /> .., ..�..._ . <br /> Test Method Used: D Pressure 0 Vacuum 19 Hydrostatic <br /> C Other(Specify) <br /> Test Equir+mentrrsPd; INCON TS—STS l guipmen±.Resolution: 0.0001 <br /> Fill Sump#87SyphFil]Sump# 8 7 Ma Fill Sump#8 7 S l a Fill Sump#91 <br /> 4umn Diameter- 48" 1 4811 4811 4811 <br /> Sump Death 5 3 7 5211 5111 _ 4 8" _ <br /> Height from Tank Top to Top of 20" 18 �1'9" 1 9" <br /> Hi est Piping Penetration: <br /> uaioht from To---Ton to r n.�,P�t A 36" 3 4" 3411 3 4" <br /> P________ _ <br /> Electrical Pene"tionr <br /> Condition of sump prior to Clean Clean Clean Clean <br /> testing: <br /> nTe_ +o_a 3811 36" 36" 36" <br /> Sump material. FRP FRP FRP FRP <br /> Wait time between applying <br /> pressure/vacuum/water and 1 0 m i n 1 0 m i n 1 0 m i n 10min <br /> Test Start Time: 2:3 7 m 2:3 7 m 1 :2 0 m 1 :2 0 m <br /> Initial Readin2.9729" 5.6302" 4.6563" 4.5983" <br /> Test End Time: 2: 5 2 pm 2 :522m 1 : 3 5 m 1 :35 m <br /> l rinaiRtc adingkrcxj: g 2.9730 i 5.6303" 4 .656_6" 4. 5982" p <br /> Test Duration: 1 5min T 1 5min 1 5min 1 5min " <br /> Change in ReadinR, : 0.0001 0.0001 '" 0.0003" 0.0001 " <br /> Pass/Fail Threshold or Crite6 ±0.002" ±0.002" ±0.002" ±0 0 02" <br /> Test Result: :& Pass 0 Fail N Pass D Fail 9 Pass Dftilj 3 Pass D Fail <br /> Is there a sensor in the sump'! 9 Yes D No I &Yes D No 9 Yes CJ No I ZYes ❑No <br /> Does the sensor alarm when 4]yes D No DNA <br /> either product or water is ISYes D No DNA ffYes 0 No 0 NA Z Yes 0 No D NA <br /> � _ I <br /> Was sensor removed for testing? IBYes D No ❑NA 3 Yes 0 No 0 NA INYes 0 No DNA &Yes 0 No 0 NA <br /> Wac sensor rrronerly replaced and IRV&s n Nn n NA <br /> verified functional after testings I m r es u No u NA x t es u No u_NA I Si r"es a ivo a i�A <br /> Comments (include information on repairs made prior to testing and recommendedfollow-upforfailed tests) <br />