Laserfiche WebLink
0� 0 <br />CALIFOnN1A <br />Water Boards <br />State Water Resources Control Board <br />January 23, 2013 <br />Mr. Don Mukai <br />S. Bravo Systems, Inc. <br />2929 Vail Avenue <br />Commerce, CA 90040 <br />Dear Mr. Mukai: <br />1,9; -3 '(0(0 3 2d, (try-\ <br />EolnuHo G. BnowH JF,. <br />:'*•'��E oorenuon <br />IlIATiHEW RDDmDUE2 <br />lECRETAnr FOn <br />FnvIRON�IENiAL FTOTEC710N <br />REVISED APPROVAL OF THE DISPENSER CONVERSION FRAME, MODEL CONV- <br />B2000/CONY-82000-OPP AS AN UNDER -DISPENSER $PILL CONTAINMENT OR <br />CONTROL SYSTEM TO INCLUDE PROVISIONS FOR THE CONY RETROFIT PLATE <br />KIT INSTALLATION <br />This letter is in response to your application for approval of the revised S. Bravo <br />Systems, Inc. (Bravo) Dispenser Conversion Frame, model CONV-B2000/CONV- <br />B2000-OPP (CONV-62000) including the CONY Retrofit Plate Kit. This revised <br />approval letter of the Bravo Dispenser Conversion Frame CONY -132000 including the <br />CONY Retrofit Plate Kit supersedes the State Water Resources Control Board's (State <br />Water Board) approval letter dated April 8, 2008. <br />Description of the CONV-132000 <br />The CONV-132000 is a conversion frame designed to allow larger dispensers to be <br />installed above smaller existing under -dispenser containment (UDC). When piping <br />within the dispenser falls outside the footprint of the UDC, the CONY -132000 is designed <br />to direct any leaking product into the UDC where it will be contained and detected, as <br />required by California regulations. <br />The CONV-132000 is fabricated of galvannealed and epoxy'powder coated 12 gauge <br />(0.093" thickness) steel. It is designed to prevent interference of the UDC water splash <br />guard, and includes a water splash guard to prevent water intrusion. The CONY -132000 <br />provides angles to drain releases back into existing UDC using a weir system of <br />drainage. Enclosure 1 shows a typical drawing of the CONV-B2000. Exact dimensions <br />are determined when an owner or operator sends UDC and dispenser information to <br />1 For a detailed explanation of the requirements for dispenser piping refer to the State Water Board's <br />December 21, 2007 letter "Clarification of Existing Regulations for Under -Dispenser Containment:" <br />CHARLES R. HOPPIN, CHAIRMAN I THOMAS HOWARD, EXECUTIVE DIRECTOR <br />1001 1 Street, Sacramontd, CA 95814 1 Molina Address: P.O. Box 100, Sacramento, CA 95812.0100 1 www.watelboards.ea.gov <br />C4 nLavcico PA,cn <br />