COMPLIANCE INFO 2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:13:59 PM
Creation date
2/26/2019 12:07:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
506
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.si oq v_org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ARP MINI MART CORP 25775 S PATTERSON PASS RD, TRACY March 27, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. For TA0170807 (Tank 1, 87 slave) and <br /> TA0170809 (Tank 3, 87 siphon), beneath "Pipe Monitoring is Performed Using the Following Method(s)"change <br /> "Yes" to "No" for"Electron Line Leak Detector Performs 3 GPH Leak Test." For TA0170808 (Tank 2, Master) and <br /> TA0170810 (Tank 4, premium unleaded) beneath "Pipe Monitoring is Performed Using the Following Method(s)" <br /> enter"Yes" for"ELLD Triggers Automatic Pump Shutdown" and "Yes"for"ELLD Failure/Disconnect Triggers <br /> Automatic Shutdown." <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log <br /> into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a repeat violation, Class Il. <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> A cold start was documented by the designated operator on October 21, 2016. The designated operator noted in <br /> the 10/28/16, 11/28/16, 12/30/16, 1,25/17 and 2/28/17 designated operator monthly inspection reports that upon <br /> arrival, the Veeder Root console was showing sudden loss alarms on T1, T2, T3 and T4. No alarm history was <br /> available. The designated operator noted all alarm histories were Iosg'due to a cold start done by the contractors <br /> working during dispenser replacements. The designated operator indicated sensors, TLMs and PLLDs need to be <br /> tested for"operability" tests. The designated operator stated that the owner needs to have the issues corrected <br /> "ASAP." <br /> Upon arriving for the monitoring system certification on 3/27/17, it was noted that the sudden loss alarm was <br /> documented in the panel printout for T1, T2, T3 and T4 for March 2017, January 2017 and December 2016. <br /> There was a work order on 3/9/2017 addressing the sudden loss alarm, however, there was a sudden loss alarm for <br /> T2 Blue Master on 3/13/2017 indicating the sudden loss alarm has not been properly addressed. Immediately have <br /> a properly licensed trained and certified contractor address the alarms. <br /> This is a minor violation. <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> A permit to inspect the conversion frames and piping leaks for the four dispensers installed in October 2016 was not <br /> submitted to the Environmental Health Department(EHD)for approval. Immediately submit a permit application for <br /> a four newly-installed dispensers. <br /> This is a minor violation. <br /> FA0003619 PR0231708 SCO01 03/27/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.