My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:26:33 PM
Creation date
2/26/2019 12:19:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
268
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quuv <br /> c S A W-d 0 A�d IN Environmental Health Department <br /> COUNTY Linda Turkatte, REHS, Director <br /> °�cFoP% Greotness grows here. Kasey Foley,REHS,Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS, RDI <br /> Rodney Estrada, REHS <br /> Willy Ng, REHS <br /> Muniappa Naidu, REHS <br /> July 27, 2018 <br /> Attn: Nick Patel <br /> Fuel Systems Consulting <br /> 39899 Balentine Drive, Suite 370 <br /> Newark, Ca. 94560 FILE C <br /> Re: ARP Mini Mart Amended SR0078577 <br /> 25775 Patterson Pass Road <br /> Tracy, Ca. 95377 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br /> amended application for a permit to open 2'X3' area south of UDC 7/8 to expose product pipes to <br /> verify crossover clearance. This amended application was a submitted to correct the piping <br /> crossover issue at UDC 7/8 after the following repairs were completed (1) replace under dispenser <br /> containments (UDCs) and dispensers on UDC 3/4 and 7/8 with new Bravo B1000 UDC and Gilbarco <br /> Encore 700 dispensers (respectively), (2) convert tank#1 (from the 87-octane to diesel), (3) change <br /> gasoline probe in Tank#1 to Veeder Root Mag Diesel probe, (4) install NOV FRP rigid diesel piping <br /> from tank #1 to UDCs 3/4 and 7/8, (5) modify existing gasoline and vapor piping to connect to the <br /> newly installed UDCs, (6) upgrade Veeder Root TLS 350 monitoring system to reflect diesel tank <br /> conversion changes, (7) disconnect 87-octane siphon line (at tank#1 and tank#2 STP sumps), (8) cap <br /> the vapor return line (at tank#1 and tank#2 STP sumps) and cap diesel vent riser (at vent stack), and <br /> (9) remove phase I vapor cap and adapter on tank#1 fill sump and install threaded pipe cap on riser <br /> on the underground storage tank (UST) system at the above noted address. The permit has been <br /> approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Zuna Barker at (209) 953-7311 to arrange the following ("a" through "c") inspection <br /> appointments (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Verify piping setback and crossover prior to backfill. <br /> b. Secondary containment testing of all exposed product piping in operating condition (once <br /> concrete is poured), per manufacturer's guidelines. One hour pressure test per <br /> manufacturer's guidelines is required, if there are no manufacturer's guidelines, this test <br /> shall be performed using an applicable method specified in an industry code or engineering <br /> standard. <br /> c. 24-hour hydrostatic test (or equivalent) on UDC 7/8. <br /> d. Overfill prevention verification: Verify that external audio and visual alarm at the newly <br /> converted diesel tank activates when tank is 90% full. Overfill prevention set up calculations <br /> must be submitted to the EHD prior to scheduling this inspection. This inspection was <br /> conducted on 7/2/18 <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.