Laserfiche WebLink
ATC Associates Inc. <br /> Quality Assurance/Quality Control Plan <br /> Revised March 1998 <br /> Equipment and well material decontamination will be conducted on an impermeable surface and all <br /> decontamination effluent will be contained. All sur1kces of the equipment will be thoroughly <br /> decontaminated using a steam cleaner. The equipment v ill be placed on a drying rack for air drying. <br /> The decontamination water will be stored in containers certified for hazardous materials storage and <br /> F <br /> disposed of in an approved manner. <br /> Sample equipment to be used for pesticides and organiC analysis will be washed in a nonphosphate <br /> detergent (Alconox or equivalent) and rinsed with tap water, followed by deionized water. If the <br /> equipment is for metals analysis, the initial rinse will be conducted with 0.1 N nitric acid followed by <br /> tap water and deionized water. ' <br /> 7.0 FIELD EQUIPMENT CALIBRATION AND MAINTENANCE <br /> The following measuring equipment may be used during the Remedial Investigation. Equipment is <br /> grouped by field activity. Calibration procedures and frequency are listed by piece. <br /> Soil Borings and Well Dimensions <br /> Well Dimensions <br /> Steel and coated cloth tape. Calibration: none. <br /> Water Level Measurements in Wells <br /> Steel surveyors tape. Calibration: manufacturersupplied temperature correction will be applied <br /> as applicable for field conditions. Electrical wel sounders. Calibration: check against steel <br /> surveyors tape. <br /> r <br /> W:1Admin13he11s1QAQC-98.DOC <br />