WALL LEGEND:
<br /> (E)WALLS TO REMAIN
<br /> NEW WALLS
<br /> SALES SST ENDCAP TO 4'-0" SCOPE OF WORK LEGEND:
<br /> O 102 AFF
<br /> A2
<br /> A2
<br /> EAS PEDESTAL � EXISTING NOT IN SCOPE
<br /> EAS PEDESTAL IN SCOPE OF WORK
<br /> 3'-11" 6'-0" T-10" T-10" 3' 10" 6'-0" 3'-11"
<br /> 1F1
<br /> TARGET®
<br /> SST END CAP I
<br /> - 1000 NICOLLET MALL
<br /> OTO T-2"AFF l FLOOR PLAN NOTESMINNEAPOLIS, MN 55403
<br /> 5" _ _ _ _ _ n @10' 0 1/2"AFF
<br /> - (E)VESTIBULE DOORS (E)CART (E)VESTIBULE DOORS 2
<br /> A. SEE SHEET A001 FOR SYMBOLS
<br /> RAIL POST TO REMAIN ¢ B. ALL DIMENSIONS ARE TO FINISH MATLS OR
<br /> TO REMAIN TO REMAIN
<br /> OPENINGS UNO, EXCLUSIVE OF CERAMIC TILE
<br /> C &EQUIP SCHEDULES,OSEE SHEET A60R SUPPLIED MAIL
<br /> 100A. :.; D. PARTITION TYPES INDICATE LOCATION FOR BLOCKING
<br /> E DIFFUSERS GRILLES
<br /> O FINISHES ETC. SEE SHEET A601 FOR PARTITION
<br /> PAINT IPS 9,C 100
<br /> II ��
<br /> . :..:. .. . .<..,... . Ll
<br /> (E)LIGHTING TO REMAIN,:.. `:`::.,.. ;, ; TYPES
<br /> L -
<br /> A301 I SEE ELECTRICAL DWGS. E. PLYWOOD BLOCKING IS INCLUDED IN PARTITION TYPE, I
<br /> SEE BLOCKING PLAN FOR SIDE OF WALL
<br /> (E)CART RAIL,GC TO VERIFY
<br /> I� EXISTING CONDITIONS AND CONFIRM WITH
<br /> i F. FOR TYPICAL CONNECTION OF INTERIOR PARTITIONS TO r
<br /> ENTRY CARTS PM IF CARTS RAILS TO BE REPLACED I 100 1006 EXTERIOR WALLS SEE
<br /> V
<br /> VESTIBULE 100A EXIT ` (E)LIGHTING TO
<br /> 2
<br /> 100 6 A301 A301 4 VESTIBULE REMAIN, PAINT LIGHT A501 TYP
<br /> a
<br /> . . . . .. . ..: . . .. ... ..
<br /> 1006 TRIMIPS 9 C-100 100A
<br /> A301ILJ
<br /> - E VESTIBULE DOORS E VESTIBULE DOORS I G. FOR PARTIAL HEIGHT PARTITION BRACING AND FLOOR
<br /> O O E)GYP BD CEI ATTACHMENT DETAILS SEE
<br /> TO REMAIN I TO REMAIN12 13
<br /> 0' 0" FF
<br /> TO.BE PAINTED IPS-1;:. FACA502 A502
<br /> 100.1 \ 1008. G100:
<br /> O O
<br /> -..:. .:.. . .... .. . .. ;. ., .. ...... IPS 10
<br /> 100A. H. ALL ANGLES ARE 45 DEGREE OR MULTIPLES OF 45
<br /> T
<br /> EPA T . : :
<br /> DEGRE NLESS NOTED OTHERWISE 4 61 FROM ROAD PA R A M U S, N J 0 7 6 5 2
<br /> J. FOR STUD WALLS EXTENDING TO ROOF
<br /> ( ) T 973.253.9393 WWW.SARGARCH.COM
<br /> II
<br /> . . ... .... .. .. . ...
<br /> )� ;,.::`. ` `.,`: .:.: :�'.: .:::::..: :. ... .:: . .. •.-...: :... . , . ... ::: . .. : ::,:.:....., . • : ,.. . . . ..: . : :.:.. .`. ;:•.:. ; DECK, SEE
<br /> ,
<br /> TYP
<br /> hh
<br /> (E)CART RAIL,GC TO VERIFY K
<br /> REVISIONS
<br /> .... .: .. .. ... ..
<br /> . . (E)GYP BD CEILING; ..•:::::. ; (.:.. .. .: :.<..: : .•'. EXISTING FIRE EXTINGUISHERS ARE TO REMAIN IN THEIR
<br /> EXISTING CONDITIONS AND CONFIRM 10' 0"AFF DATE N0. DESCRIPTION
<br /> .. ..... ........ . .: . :... .. .. .. . .. '.:. . . ...: @ ,. CURRENT LOCATIONS. IF A FIRE EXTINGUISHER NEEDS
<br /> WITH PM IF CARTS RAILS TO BE ;. . TO BE PAINTED 01117/19 ISSUED FOR PERMIT
<br /> REPLACED EFS 2R;:C.6.. : ..,..::: ::':'. EXTINGUISHER&SIGNS OR ASSOCIATED ITEMS ARE TO
<br /> BE RELOCATED AND INSTALLED
<br /> N FARTHER THAN 1
<br /> q - - - - - - - - - - - - - - - - - - - - - - - q - - - - - - - - - - - - -
<br /> ,:... .. .� T�.::.�. .- . .ter.. ..
<br /> ...
<br /> , .:. ... ..: . '.°: FROM ITS CURRENT LOCATION.
<br /> E MARSHAL
<br /> FINAL LOCATIONS PENDING FIR
<br /> WALK-THROUGH INSPECTION.
<br /> (E)GIMP BD.CEIL'ING
<br /> 14. .o.1/2. AFF FINISH PLAN GENERAL NOTES
<br /> . . . . ... . ..
<br /> TO BE PAINTED
<br /> O EFS SEE SHEET A001 FOR SYMBOLS
<br /> -2R 6
<br /> G ,
<br /> A
<br /> B. FOR ADDITIONAL INFORMATION, SEE DOOR, ROOM
<br /> FINISH,AND OWNER SUPPLIED MATL&EQUIP
<br /> SCHEDULES-SHEET A601
<br /> C. ALL CPT, RF, RB,CT, QT, FTS, SSM,AND MT ARE FURNISHED
<br /> (E)LIGHTING TO PAINT LIGHT TRIM BY OWNER AND INSTALLED BY GENERAL CONTRACTOR
<br /> BE REPLACED SEE EFS-2R,C-6 ALL K-PANEL, FRP&MARMOLEUM ARE FURNISHED BY
<br /> ELECTRICAL DWGS. OWNER AND INSTALLED BY GENERAL CONTRACTOR
<br /> D2 D3 D4
<br /> 1 ENTRY FLOOR PLAN 2 ENTRY REFLECTED CEILING PLA D. CURVED FLOORING NODES E BE PROCUREDBY
<br /> FTARGET
<br /> LOORING.AND CUSTOM MANUFACTURED BY ARMSTRONG FLOORING.
<br /> A301 SCALE: 1/4" = V-0" A301 SCALE: 1/4" = V-0" INSTALL CURVED FLOORING NODES PER SPECIFICATIONS
<br /> AND MANUFACTURER'S INSTALLATION INSTRUCTIONS.
<br /> CONTACT DAVID ROPERTI WITH QUESTIONS AT
<br /> DLROPERTI@ARMSTRONGFLOORING.COM
<br /> E. ALL SALES FLOOR COLUMNS RECEIVE STAINLESS STEEL
<br /> BASE. NO RESILIENT BASE AT COLUMNS, SEE 19
<br /> A502
<br /> F. INSTALL HYDRAULIC CEMENT BASED UNDERLAYMENT
<br /> TO CREATE FEATHERED EDGE AT TRANSITION
<br /> BETWEEN RESILIENT FLOORING AND EXPOSED
<br /> CONCRETE FLOOR ON ALL SIDES.
<br /> G. FLOOR FINISH CHANGES BETWEEN ROOMS OCCUR AT
<br /> DOOR CENTERLINES TYPICAL.SEE A601 FOR ADDITIONAL
<br /> FLOOR FINISH INFORMATION.
<br /> H. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL
<br /> CORNER GUARD-VERIFY REUSE OF EXISTING CORNER
<br /> GUARD
<br /> AV J. SST CORNER GUARDS AND WALL CAPS TO 4'-0"AFF UNLESS
<br /> WALL PROTECTION IS TO 7'-2"AFF IN WHICH CASE THE SST
<br /> CORNER GUARD OR WALL CAP WILL TERMINATE AT THE
<br /> RF 2 SAME HEIGHT AS THE WALL PROTECTION.
<br /> iII(_ FTS-4B –
<br /> K. FOR SST CORNER GUARD/VERTICAL SST END CAPS TO
<br /> RF 1 RB CONNECTION SEE
<br /> B/0 ACT GEEING 11
<br /> CPT-15 RF-1 EL=114'-0" A502
<br /> FTS-4B (E)GYP BULKHEAD L. INSTALL REDUCER STRIP(FTS-1A UNO)AT TRANSITION
<br /> EL=10'-0"AFF BETWEEN RESILIENT FLOORING AND BROAD LOOM CARPET.
<br /> PAINT ALL SIDES
<br /> IPS 1, C-36 M. INSTALL REDUCER STRIP FTS-2 AT TRANSITION BETWEEN
<br /> 11'-4" 8'-9" � ( )
<br /> B/0 ACT GEEING B/0 ACT GEEING RESILIENT FLOORING AND EXPOSED CONCRETE FLOOR ON
<br /> EL=110'-0" EL=110'0" ALL SIDES. PROFESSIONAL OF
<br /> IPS-1,C-36 IPS-1,C 9
<br /> FTS-4B (E)STOREFRONT
<br /> / (E)STOREFRONT RECORD SEAL
<br /> N. DO NOT APPLY ANY SEALANT UNDER CT.
<br /> FTS 4B
<br /> OPEN TO SALES SYSTEM TO SYSTEM TO
<br /> K-201 � REMAIN REMAIN P. FOR K-PANEL WALL CAP, CORNER GUARD AND END
<br /> INTERIOR \ CAP DETAILS SEE
<br /> / EXTERIOR 10 11 12 17 18
<br /> � �, K-11 \ A502 A502 A502 A502 A502 p ARC
<br /> 0 12'-5" 20'-1" O � - '_
<br /> O � (E)DOORS TO (E)DOORS TO �G
<br /> EAS PEDESTAL REMAIN / REMAIN `�
<br /> ROBERT J.SARGENTI
<br /> RB-1A / * No. C-31054
<br /> Z z
<br /> LEVEL 1-T/O SLAB LEVEL 1-T/0 SLAB 07/31/1
<br /> SALES EL=100'-0" EL=100'-0" Lp Ren
<br /> FTS 4B 102
<br /> SST ENDCAP TO 4'-0" RB-1A
<br /> AFF INTERIOR ELEVATION NOTES CA
<br /> —CPT-1r M A L JOINTS SHOWN ARE SPECIAL
<br /> CONDTOIONSS ONLY. REFER TO PROJECT MANUAL
<br /> RF 1 4 ENTRY INTERIOR ELEVATION 5 ENTRY INTERIOR ELEVATION CRITERIA FOR LOCATION AND SPACING OF ALL
<br /> N O D O D D D O D O D a m A301 SCALE: 1/4" = V-0"
<br /> DD
<br /> N A301 SCALE: 1/4" = 1'-0" OTHER CONTROL JOINTS
<br /> LL > C, B. FOR ADDITIONAL FINISH INFORMATION
<br /> Q m c� SEE ROOM FINISH SCHEDULE-SHEET A601
<br /> N Q
<br /> F-_ CO
<br /> O � Y a C. RB SHOWN AT ALL EXPOSED WALLS AND EXTENDS 6"
<br /> BEHIND FIXTURES RB IS ALSO PLACED IN AREAS WITH
<br /> - N a \ a WC-6 AND AT JEWELRY BOAT FIXTURE
<br /> Y _ O
<br /> i
<br /> D. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL
<br /> CORNER GUARD-VERIFY REUSE OF EXISTING CORNER O
<br /> GUARD M
<br /> _ v /
<br /> L 13'-91/2" I 3'-9" I 13'-91/2" E. ALL 7-1/4"OR GREATER WALL THICKNESSES TO HAVE(2) Lo
<br /> �I SEPARATE OUTSIDE STAINLESS CORNER GUARDS. IF
<br /> J WALL THICKNESS IS LESS THAN 7-1/4"USE(1) FULL WALL
<br /> CPT 15 ENTRY EXIT _ THICKNESS STAINLESS STEEL END CAP
<br /> U- > VESTIBULE o o CARTS VESTIBULE uj
<br /> I ¢ m 100 100A 1006 o Q m F. PAINT TO EXTEND MIN 6"BEHIND FIXTURES. DO NOT
<br /> �, Q �, Q SAND OR PAINT GYPSUM BOARD CONSTRUCTION THAT IS
<br /> F CONCEALED BY FIXTURES
<br /> � 0 0
<br /> �CPT-
<br /> C/)
<br /> MT2oG. VERIFY FINAL FIXTURE LOCATIONS W/OWNER
<br /> I Y B/0 ACT CELING
<br /> \ I EL (E)GYP BULKHEAD H. FOR CONTROL JOINTS SEE 3 5 TYP
<br /> � K-201 I I EL=10'-0"AFF A501 A501
<br /> IPS-1,C-36 PAINT ALL SIDES I. PROVIDE SLIP CONTROL JOINT AT ALL LOCATIONS U
<br /> A (� A IPS-1, C-36 WHERE ROOF SUPPORTED BULKHEAD ABUTS FLOOR
<br /> SUPPORTED
<br /> B/0 ACT GEEING B/0 ACT GEEING 4 ..
<br /> EL=110'-0" EL=110'0" WALL-SEE A501 Q
<br /> II )� IPS-1,C-9 � TYP
<br /> „ (E)STOREFRONT
<br /> 10-4 i � � (E)STOREFRONT J. ALL HM DOORS AND FRAMES ON SALES FLOOR TO BE
<br /> OPEN TO OPEN SYSTEM TO SYSTEM TO PAINTED TO MATCH ADJACENT WALL SURFACE LINO
<br /> CIRCULATION TO REMAIN REMAIN W
<br /> EXTERIOR SALES SST END CAP / K. ANY EXPOSED WALL SURFACES GREATER THAN OR W
<br /> TO T-2"AFF EQUAL TO 18"ADJACENT TO INTERIOR SALES FLOOR
<br /> SURFACE MOUNTED I
<br /> INTERIOR I I HARDLINES DOOR LOCATIONS TO RECEIVE KYDEX TO A J
<br /> DISPLAY WINDOW HEIGHT OF T-2". KYDEX COLOR SELECTION, K-11 OR
<br /> `� (E)DOORS TO (E)DOORS TO K 201,TO MATCH ADJACENT WALL SURFACE.
<br /> ~ \ REMAIN \ REMAIN
<br /> Z
<br /> K11 ` REFLECTED CEILING PLAN NOTES o
<br /> RB 1A
<br /> LEVEL 1-T/0 SLAB z 7LEVEL 1-T/0 SLAB Q
<br /> EL=100'-0" EL=100'-0" A. SEE SHEET A001 FOR SYMBOLS. 00
<br /> RB-1A N
<br /> B. VERIFY LOCATIONS OF HANGING DEPARTMENT SIGNS
<br /> SST CORNER WITH TARGET'S IN STORE MARKETING. LOCATIONS
<br /> GUARD TO 7'-2"AFF SHOWN ARE FOR REFERENCE ONLY 6
<br /> A501 S1
<br /> 3 ENTRY FINISH PLAN 6 ENTRY INTERIOR ELEVATION 7 ENTRY INTERIOR ELEVATION C. ACT CEILING GRIDS ARE CENTERED IN ROOMS PER
<br /> SPECIFICATION 09 5100 CRITERIA UNLESS NOTED
<br /> A301 SCALE: 1/4" = V-0"
<br /> A301 SCALE: 1/4" = 1'-0"
<br /> A301 SCALE: _ -
<br /> OTHERWISE
<br /> D. PROVIDE SLIP CONNECTION AT ALL WALLS EXTENDING PROJECT NUMBER: T-0738
<br /> TO ROOF OR STRUCTURE-SEE
<br /> 8
<br /> A501 TYP CONFIG: LL
<br /> E. PROVIDE QUANTITY AND LOCATION OF DIRECTIONAL/
<br /> EXIT SIGNS AS REQUIRED BY FIRE MARSHAL HAVING DRAWN BY: J.P. RIOS
<br /> JURISDICTION
<br /> F. REFER TO ELECTRICAL/MECHANICAL FOR LIGHT CHECKED BY: G.ABREU-GARCIA
<br /> FIXTURE AND DIFFUSER RELOCATION. COORDINATE
<br /> FOR REMOVAL/REUSE OF LIGHTS, DIFFUSERS AND
<br /> SPRINKLER HEADS
<br /> G. FOR ALIGNMENT OF SPRINKLER IN SALES FLOOR CEILING ENTRY PLANS,
<br /> SEE SPEC, DIV 21
<br /> H. FOR CEILING GRID BRACING AND EDEGE CONDITIONS IN ELEVATIONS &
<br /> SEISMIC DESIGN CATEGORY-SEE 2 3 4
<br /> A131 A131 A131 DETAILS
<br /> CEILING LEGEND
<br /> (E)ACT NEW ACT
<br /> CEILING CEILING
<br /> (E)GYP BD NEW GYP BD
<br /> CEILING CEILING
<br /> 1/17/2019 5:21:34 PM
<br />
|