Laserfiche WebLink
WALL LEGEND: <br /> 1 2 1 2 <br /> (E)WALLS TO REMAIN <br /> I I <br /> NEW WALLS <br /> I I <br /> SCOPE OF WORK LEGEND: <br /> tt - - - - - - - - - - I - - - - - - - D - - - - - - - - - - - - - - - - - - - - - - - EXISTING NOT IN SCOPE <br /> M I I 10 REUSE EXISTING STRUCTURE IN SCOPE OF WORK <br /> A302 i FOR NEW STOREFRONT. <br /> EXTEND STRUCTURE TO TARGET <br /> _j <br /> C? MATCH WHERE EXISTING <br /> STRUCTURE ENDS <br /> 1000 N(COLLET MALL <br /> I <br /> FLOOR PLAN NOTES MINNEAPOLIS, MN 55403 <br /> 0S6 ' A. SEE SHEET A001 FOR SYMBOLS <br /> 0 <br /> 4'-0"BULLSEYE <br /> B. ALL DIMENSIONS ARE TO FINISH MATLS OR <br /> r, I AND"TARGET"TEXT <br /> LOCKUP SIGN OPENINGS LINO, EXCLUSIVE OF CERAMIC TILE <br /> asoz 7 C. FOR DOOR, ROOM FINISH,AND OWNER SUPPLIED MATL <br /> o (E)GYP BD CEILING <br /> M (E)BULKHEAD TO BE &EQUIP SCHEDULES,SEE SHEET A601 <br /> @9 6"AFF PAINT IPS-1,C-36 z <br /> D. PARTITION TYPES INDICATE LOCATION FOR BLOCKING, <br /> FINISHES, ETC. SEE SHEET A601 FOR PARTITION <br /> GL-15 T TYPES I <br /> o 9: E. PLYWOOD BLOCKING IS INCLUDED IN PARTITION TYPE, Ll <br /> SEE BLOCKING PLAN FOR SIDE OF WALL <br /> A302 <br /> ACT-1 <br /> @ 14'-0"AFF F. FOR TYPICAL CONNECTION OF INTERIOR PARTITIONS TO v <br /> EXTERIOR WALLS-SEE <br /> 2 <br /> 3'-6" � (E)SOFFIT TO BE A501 <br /> M <br /> PAINT IPS 1,C-1 TYP <br /> g G. FOR PARTIAL HEIGHT PARTITION BRACING AND FLOOR / <br /> A302 ATTACHMENT DETAILS-SEE ` <br /> rl2y 13 <br /> a i A502 A502 <br /> i r ^ <br /> i V <br /> 102 H. ALL ANGLES ARE 45 DEGREE OR MULTIPLES OF 45 <br /> SALES s "302 iE ACT <br /> 0 102 DEGREE, UNLESS NOTED OTHERWISE <br /> ( ) 461 FROM ROAD, PARAMUS, NJ 07652 <br /> 14' 0"AFF <br /> � @ - J. FOR STUD WALLS EXTENDING TO(E)ROOF <br /> 5 , DECK, SEE TI973.253.9393 WWW.SARGARCH.COM <br /> i 8 <br /> A501 TYP <br /> SST GUARD TO 7R2 "AFF REVISIONS <br /> O i K. EXISTING FIRE EXTINGUISHERS ARE TO REMAIN IN THEIR <br /> CURRENT LOCATIONS. IF A FIRE EXTINGUISHER NEEDS DATE NO. DESCRIPTION <br /> EAS PEDESTAL (E)GYP BD CEILING TO BE RELOCATED DUE TO FIXTURE SHIFTS,THE FIRE 01117119 ISSUED FOR PERMIT <br /> M @9' 0"AFF EXTINGUISHER&SIGNS OR ASSOCIATED ITEMS ARE TO <br /> BE RELOCATED AND INSTALLED NO FARTHER THAN 10'-0" <br /> FROM ITS CURRENT LOCATION. <br /> SST CORNER FINAL LOCATIONS PENDING FIRE MARSHAL <br /> GUARD TO T-0"AFF 124 WALK-THROUGH INSPECTION. <br /> I <br /> ACT FINISH PLAN GENERAL NOTES <br /> SEATING <br /> 124 c I o A. SEE SHEET A001 FOR SYMBOLS <br /> B. FOR ADDITIONAL INFORMATION, SEE DOOR, ROOM <br /> FINISH,AND OWNER SUPPLIED MATL&EQUIP <br /> SCHEDULES-SHEET A601 <br /> C. ALL CPT, RF, RB,CT, QT, FTS, SSM,AND MT ARE FURNISHED <br /> BY OWNER AND INSTALLED BY GENERAL CONTRACTOR <br /> 1 MALL ENTRY FLOOR PLAN <br /> 2 MALL ENTRY REFLECTED CEILING PLAN ALL K-PANEL, FRP&MARMOLEUM ARE FURNISHED BY <br /> A302 SCALE: 1/4" = V-0" <br /> A302 SCALE: 1/4" - 1'-0" OWNER AND INSTALLED BY GENERALCONTRACTOR <br /> 1 D2 D3 D4 <br /> 1 3"6 2 D. CURVED FLOORING NODES TO BE PROCURED BY TARGET <br /> AND CUSTOM MANUFACTURED BY ARMSTRONG FLOORING. <br /> INSTALL CURVED FLOORING NODES PER SPECIFICATIONS <br /> 1 2 B/0 ACT CELING B/0 ACT CELING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> EL=114'-0" EL=114'-0" CONTACT DAVID ROPERTI WITH QUESTIONS AT <br /> I\ 1 DLROPERTI@ARMSTRONGFLOORING.COM <br /> J1 I E. ALL SALES FLOOR COLUMNS RECEIVE STAINLESS STEEL <br /> GL 15 \ I \ I BASE. NO RESILIENT BASE AT COLUMNS, SEE 19 <br /> I IPS-1,C-36 <br /> CPT-301--------- 13 <br /> FTS-1A B/0 ACT CELING B/0 ACT GEEING <br /> � � I OPEN TO 1 <br /> EL=109'-6" SALES I \ I EL=109'-6" F. INSTALL HYDRAULIC CEMENT BASED UNDERLAYMENT <br /> \ OPEN TO I (E)GYP. BD TO CREATE FEATHERED EDGE AT TRANSITION <br /> (E)GYP. BD � SALES � I 1 1 <br /> SOFFIT TO BE I SOFFIT TO BE BETWEEN RESILIENT FLOORING AND EXPOSED <br /> I PAINT IPS 1,C 1 \ / I 1 I PAINT IPS-1,C-1 CONCRETE FLOOR ON ALL SIDES. <br /> V <br /> I 1 K-201 G. FLOOR FINISH CHANGES BETWEEN ROOMS OCCUR AT <br /> INTERIOR \ INTERIOR I 1 MALL ENTRANCE DOOR CENTERLINES TYPICAL.SEE A601 FOR ADDITIONAL <br /> FLOOR FINISH INFORMATION. <br /> D - - - - - - - - - - - - - - - - �- - - - - - - O MALLENTRANCE / \ <br /> If <br /> \ <br /> SST CORNER <br /> EAS PEDESTAL I 1 1 ti GUARD TO T-2"AFF H. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL <br /> 30'-91/2" i �l I _ \ CORNER GUARD-VERIFY REUSE OF EXISTING CORNER <br /> RB-1A <br /> I1 1 J. SST CORNER GUARDS AND WALL CAPS TO 4'-0"AFF UNLESS <br /> LEVEL 1-T/0 SLAB - /0 SLAB WALL PROTECTION IS TO T-2"AFF IN WHICH CASE THE SST <br /> RF-2 EL=100'-0" EL=100'-0" CORNER GUARD OR WALL CAP WILL TERMINATE AT THE <br /> 13 SST CORNER SAME HEIGHT AS THE WALL PROTECTION. <br /> A302 BRUSHED <br /> SST CLADDING GUARD TO 4'-0"AFF <br /> K. FOR SST CORNER GUARD/VERTICAL SST END CAPS TO <br /> 1'6 1/2' 29'-8 3l4" ON BOTH SIDES RB CONNECTION SEE 11 <br /> OF 6"BASE RAIL <br /> A502 <br /> L. INSTALL REDUCER STRIP(FTS-1A UNO)AT TRANSITION <br /> 4 <br /> INTERIOR ELEVATION MALL ENTRY 5 INTERIOR ELEVATION MALL ENTRY BETWEEN RESILIENT FLOORING AND BROAD LOOM CARPET. <br /> A302 SCALE: 1/4" = V-0" A302 SCALE: 1/4" = V-0" M. INSTALL REDUCER STRIP(FTS-2)AT TRANSITION BETWEEN <br /> RESILIENT FLOORING AND EXPOSED CONCRETE FLOOR ON <br /> ALL SIDES. PROFESSIONAL OF <br /> 7'-7 3/4" S6 <br /> 4'-0"BULLSEYE N. DO NOT APPLY ANY SEALANT UNDER CT. RECORD SEAL <br /> AND"TARGET"TEXT <br /> D LOCKUP SIGN P. FOR K-PANEL WALL CAP, CORNER GUARD AND END <br /> CAP DETAILS SEE <br /> IPS-1,C-1 T/0 BULKHEAD <br /> 17 18 <br /> D EL=118'-0" A502 A502 A502 A502 A502 k011.�`��D A R C7Yj�� <br /> 14'-8" �G �,� <br /> 5'-3 1/2" 26'-5 3/4" 9 w ROBERT J.SARGENTI <br /> No. C-31054 <br /> B/0 ACT GEEING <br /> - I EL=114'0" a O (E)BULKHEAD 07/31 <br /> GL-15 T <br /> R <br /> A502 0 IPS-1,C-36 14 T O� <br /> CT-44&CT-45 RF-1 i A302 I IPS-1,C-36 "' 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 2'-1 3/4" INTERIOR ELEVATION NOTES c <br /> SALES ML B/0 ACT CELING B/0 ACT CELING <br /> ' EL-109'6" EL-109'-6" A. CONTROL JOINTS SHOWN ARE SPECIAL <br /> K-201 TO T-2"AFF K-201 TO 4'-0"AFF 102 I \ \ GL-15 T CONDITIONS ONLY. REFER TO PROJECT MANUAL <br /> IPS-1,C-36 ABOVE 12 CRITERIA FOR LOCATION AND SPACING OF ALL <br /> ' \ OPEN TO MALLS I A302 A14 \ / OTHER CONTROL JOINTS <br /> i BPEN TO . FOR ADDITIONAL FINISH INFORMATION <br /> u- K-201 \ OSALES� SEE ROOM FINISH SCHEDULE SHEET A601 <br /> FOOD o o i C. RB SHOWN AT ALL EXPOSED WALLS AND EXTENDS 6" <br /> SEATING Y �� �� BEHIND FIXTURES RB IS ALSO PLACED IN AREAS WITH <br /> WC-6 AND AT JEWELRY BOAT FIXTURE <br /> Li Li K-201 T ------13 13 D. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL <br /> CORNER GUARD-VERIFY REUSE OF EXISTING CORNER <br /> /—(E)RF-1-� i A302 A302 GUARD C) <br /> RB-1 A RB-1A m <br /> \ FIF EVEL 1-T/0 SLAB \ LEVEL 1-T/0 SLAB E. ALL 7-1/4"OR GREATER WALL THICKNESSES TO HAVE(2) LO <br /> O EL=100'-0" EL=100'-0" SEPARATE OUTSIDE STAINLESS CORNER GUARDS. IF <br /> (E)MALL WALL, FINISHES WALL THICKNESS IS LESS THAN 7-1/4"USE(1) FULL WALL <br /> BRUSHED THICKNESS STAINLESS STEEL END CAP <br /> EAS PEDESTAL SST CLADDING TO REMAIN BRUSHED <br /> ON BOTH SIDES SST CLADDING F. PAINT TO EXTEND MIN 6"BEHIND FIXTURES. DO NOT , 1 <br /> OF 6"BASE RAIL ON BOTH SIDES SAND OR PAINT GYPSUM BOARD CONSTRUCTION THAT IS v <br /> OF 6"BASE RAIL CONCEALED BY FIXTURES <br /> 3 MALL ENTRY FINISH PLAN <br /> A302 SCALE: 1/4" = V-0" 6 INTERIOR ELEVATION MALL ENTRY 7 INTERIOR ELEVATION MALL ENTRY G. VERIFY FINAL FIXTURE LOCATIONS W/OWNER <br /> A302 SCALE: 1/4" = V-0" U <br /> A302 SCALE: 1/4" - 1'-0" H. FOR CONTROL JOINTS SEE 3 5 <br /> A501 A501 TYP <br /> I. PROVIDE SLIP CONTROL JOINT AT ALL LOCATIONS U <br /> 3/16 WHERE ROOF SUPPORTED BULKHEAD ABUTS FLOOR <br /> VERTICAL AND DIAGONAL SUPPORTED 4 _ <br /> WALL-SEE A501 Q <br /> CONT. STRUCTURAL ANGLE. TYP <br /> CONT. <3"X3"X 1/4" J. ALL HM DOORS AND FRAMES ON SALES FLOOR TO BE L.L <br /> 1/4"BOLTS @ 18"OC PAINTED TO MATCH ADJACENT WALL SURFACE LINO UJ <br /> STRUCTURAL SUPPORT MUST <br /> ABLE TO WITHSTAND LOADS K. ANY EXPOSED WALL SURFACES GREATER THAN OR W <br /> IMPOSED BY GLASS SYSTEM EQUAL TO 18"ADJACENT TO INTERIOR SALES FLOOR J <br /> HARDLINES DOOR LOCATIONS TO RECEIVE KYDEX TO A <br /> VERIFY WITH GLASS HEIGHT OF T-2". KYDEX COLOR SELECTION, K-11 OR <br /> WALL MANUFACTURER K-201,TO MATCH ADJACENT WALL SURFACE. <br /> UMIUMMI Z <br /> 3x3xl/4"STL<CONT. 1 BRUSHED REFLECTED CEILING PLAN NOTESSTAINLo <br /> EXISTING BEAM AND STEEL ESS REEP IR& <br /> BAR JOISTS CLADDING---// REPLACE AS A. SEE SHEET A001 FOR SYMBOLS. 00 <br /> 3x3xl/4"STL<CONT VINYL GLASS NECCESARY N <br /> BEAD B. VERIFY LOCATIONS OF HANGING DEPARTMENT SIGNS <br /> - - - - - - - - - - - - - - - - - - E CONC. PANEL I WITH TARGET'S IN STORE MARKETING. LOCATIONS <br /> - - - - O 3/4"CLEAR <br /> SHOWN ARE FOR REFERENCE ONLY <br /> GLASS 6 S1 <br /> A501 <br /> EXISTING JOIST 3x3x1/4"STL S W/ (E)STL COLUMN CONTRACTOR TO VERIFY <br /> WELDED ` REQUIREMENTS OF E.J. <br /> i I C. ACT CEILING GRIDS ARE CENTERED IN ROOMS PER <br /> CONNECTIONS COVER&CAST REQ"D. <br /> RECEIVER CHANNELS 12 SPECIFICATION 09 5100 CRITERIA UNLESS NOTED <br /> - - - - - - - - - HEAD DETAIL CLEAR GLASS <br /> - � - - � _ _ _ _ _ _ _ _ _ _ FRAME ASSEMBLIES L - - - - - - - - <br /> - - - - - - - - - - - - - - - - <br /> @ 4'-0"O.0(MAX) I A302 SCALE: 3" = 1'-0" OTHERWISE <br /> o SUPPLIED BY MALL OWNER T-0738 <br /> VERIFY CLEARANCE I INTO SLAB D. PROVIDE SLIP CONNECTION AT ALL WALLS EXTENDING PROJECT NUMBER: <br /> 45 @ COILING DOOR <br /> I '. TO ROOF OR STRUCTURE-SEE <br /> 8 <br /> MSN' I A501 TYP CONFIG: LL <br /> I ; <br /> (E)OVER HEAD,REEL AND 9/16"OPAQUE <br /> TRACKCOILING DOOR EXPANSION E. PROVIDE QUANTITY AND LOCATION OF DIRECTIONAL/ <br /> (2)<'S VERT.& (E) 1"GYP. BD AND 3" I a RF-2 JOINT COVER GLASS DRAWN BY: J.P. RIOS <br /> (E)CENTER OF (BY OTHERS) EXIT SIGNS AS REQUIRED BY FIRE MARSHAL HAVING <br /> DIAGONAL @ 4'-0"OC METAL STUDS @ 2'-0" + 4'-0" DOOR cn �- JURISDICTION <br /> Q BRUSHED F. REFER TO ELECTRICAL/MECHANICAL FOR LIGHT CHECKED BY: G.ABREU-GARCIA <br /> o + I CD SST CLADDING <br /> (E) BULKHEAD I ��� F <br /> w 3/4"(TYP) FIXTURE AND DIFFUSER RELOCATION. COORDINATE <br /> FRAMING o SI BOTH CLEAR GLASS FOR REMOVAL/REUSE OF LIGHTS, DIFFUSERS AND <br /> MALL ENTRANCE I � INTERIOR SIDES OF 6" <br /> w BASE RAIL— <br /> (E) <br /> AIL SPRINKLER HEADS <br /> + + 3/4"GLASS I ° ° ° o <br /> (E)ACT., REPAIR& (E)ACT., WALL 5" ° G. FOR ALIGNMENT OF SPRINKLER IN SALES FLOOR CEILING <br /> REPLACE AS I I REPAIR& + + o SEE SPEC, DIV 21 <br /> NECCESARY REPLACE AS ++ + M ° ENTRY MALL PLANS , <br /> NECCESARY 7" 4" 3" 12 (E)ACT., REPAIR EXP.JT 2" o o ° H. FOR CEILING GRID BRACING AND EDEGE CONDITIONS IN <br /> 3/4'TYP. CLEAR A302 &REPLACE AS VERIFY ° ° ° NOTE:ALIGN EXPANSION SEISMIC DESIGN CATEGORY SEE 2 3 4 <br /> 12 GLASS NECCESARY - <br /> A302 (E)PROPERTY JOINT COVER W/FINISH A131 A131 A131 ELEVATIONS <br /> LINE FLOOR ELEVATIONS <br /> MALL(BY OTHERS) TARGET <br /> 113/4 <br /> s HEAD DETAIL GLASS WALL & ANCHORAGE 9 HEAD DETAIL GLASS WALL & ANCHORAGE AT COILING DOOR 10 PLAN DETAIL MALL ENTRY JAMB 11 EXPANSION JOINT DETAIL 13 SILL DETAIL CLEAR GLASS 14 CLEAR GLASS CORNER DETAIL CEILING LEGEND <br /> A302 SCALE: 1/2" = V-0" A302 SCALE: 1/2" = V-0" <br /> A302 SCALE: _ - A302 SCALE: _ - A302 SCALE: _ -01, A302 SCALE: _ - <br /> (E)ACT � NEW ACT <br /> CEILING CEILING <br /> (E)GYP BD NEW GYP BD <br /> CEILING CEILING <br /> 1/17/2019 5:29:13 PM <br />