WALL LEGEND:
<br /> (E)WALLS TO REMAIN
<br /> NEW WALLS
<br /> 3 3 3
<br /> SCOPE OF WORK LEGEND:
<br /> I I
<br /> (E)HSS COLUMNS, (E)BULKHEAD EXISTING NOT IN SCOPE
<br /> PAINT IPS-6,C-100 TYP. (UNO) @ 11'-5" AFF
<br /> IPS-1,C-36
<br /> IN SCOPE OF WORK TARGET®
<br /> ❑ ❑ _ _ _ ❑ ❑ ❑ ❑ ❑ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
<br /> 1000 NICOLLET MALL
<br /> I I �
<br /> FLOOR PLAN NOTES MINNEAPOLIS, MN 55403
<br /> A. SEE SHEET A001 FOR SYMBOLS
<br /> (E)HSS COLUMN
<br /> PAINT IPS-6,C-100 B. ALL DIMENSIONS ARE TO FINISH MATLS OR
<br /> CLEAR FINISH STEEL OPENINGS UNO, EXCLUSIVE OF CERAMIC TILE
<br /> F3 I I
<br /> END CORNER GUARD F1 6 A303 a C. FOR DOOR, ROOM FINISH,AND OWNER SUPPLIED MATL
<br /> TO 4'-0"AFF GUEST SERVICE REGISTRY COUNTER &EQUIP SCHEDULES, SEE SHEET A601
<br /> i COUNTER @ 34"AFF @ 34"AFF MAX. HT CLEAR FINISH STEEL 7
<br /> MAX. HT s END WALL PLATE TO D. PARTITION TYPES INDICATE LOCATION FOR BLOCKING, L
<br /> 1F1 16N8 T/0 WOOD CLADDING = FINISHES, ETC. SEE SHEET A601 FOR PARTITION
<br /> if
<br /> "IJi TYPES I
<br /> 8 GUEST E. PLYWOOD BLOCKING IS INCLUDED IN PARTITION TYPE,
<br /> GUEST 0 ❑ c A304 FOR ADJACENT SERVICES SEE BLOCKING PLAN FOR SIDE OF WALL
<br /> SERVICES 103 FINISHES,SEE m 103 r
<br /> M 103 3 a / F. FOR TYPICAL CONNECTION OF INTERIOR PARTITIONS TO v
<br /> z E, �il_ L I A301 = a EXTERIOR WALLS-SEE
<br /> CLEAR FINISH STEEL o (E)ACT :;*-
<br /> CLEAR RF-1 K-11 TO 4'-0"AFF 2
<br /> a FINISH STEEL EL=10'-0 1/2"AFF o cv A501 TYP
<br /> 5N1 CORNER GUARD CORNER GUARD TO T/0 IPS 2A,C 9 ABV rt
<br /> TO 4'0"AFF 5'0" WOOD CLADDING cit
<br /> 1' 16'-11" 7'-0" Y K-11 TO 4'-0"AFF WOOD CLADDING G. FOR PARTIAL HEIGHT PARTITION BRACING AND FLOOR
<br /> 2B ALIGN PWS-1 ABV ATTACHMENT DETAILS SEE
<br /> 16N1 12 13
<br /> A304 A502 A502
<br /> L
<br /> FIL
<br /> 1 2A 2B H. ALL ANGLES ARE 45 DEGREE OR MULTIPLES OF 45
<br /> ALIGN 16'-10" DEGREE, UNLESS NOTED OTHERWISE
<br /> A304 A304� A304 CLEAR FINISH STEEL o0 5 ACT-1 IPS 1,C 36 FULL HT 00
<br /> 4 I K-11 TO 4'-0"AFF RF1 461 FROM ROAD PARAMOS, NJ 07652
<br /> CORNER GUARD 9 "' A304 A304 EL=10'-0"AF `' FTS-2A IPS-2B,C-9 ABV J. FOR STUD WALLS EXTENDING TO(E)ROOF T1973.253.9393 WWW.S A R G A R C H.C O M
<br /> TO 4'-0"AFF A304 z I DECK, SEE 8
<br /> TYP
<br /> J ALIGN A501 REVISIONS
<br /> i ¢ I FLEXIBLE -77
<br /> FTS-2A K. EXISTING FIRE EXTINGUISHERS ARE TO REMAIN IN THEIR
<br /> FLEXIBLE 5'-6" FULFILLMENT IPS-1,C-36 FULL HT = CURRENT LOCATIONS. IF A FIRE EXTINGUISHER NEEDS DATE NO. DESCRIPTION
<br /> FULFILLMENT Z 103A 103A J TO BE RELOCATED DUE TO FIXTURE SHIFTS,THE FIRE 01/17/19 ISSUED FOR PERMIT
<br /> 103A 8F1S o
<br /> Q M EXTINGUISHER&SIGNS OR ASSOCIATED ITEMS ARE TO
<br /> z :mm (E)ACT SEALED CONCRETE c? BE RELOCATED AND INSTALLED NO FARTHER THAN 10'-0"
<br /> (E - 10' 0"AFF 1_ FROM ITS CURRENT LOCATION.
<br /> ILA a FINAL LOCATIONS PENDING FIRE MARSHAL
<br /> IPS-1,C-100 FULL HT — WALK-THROUGH INSPECTION.
<br /> � I �
<br /> _ - FINISH PLAN GENERAL NOTES
<br /> fi
<br /> A. SEE SHEET A001 FOR SYMBOLS
<br /> i B. FOR ADDITIONAL INFORMATION, SEE DOOR, ROOM
<br /> FINISH,AND OWNER SUPPLIED MATL&EQUIP
<br /> SCHEDULES-SHEET A601
<br /> I I I
<br /> C. ALL CPT, RF, RB,CT, QT, FTS, SSM,AND MT ARE FURNISHED
<br /> BY OWNER AND INSTALLED BY GENERAL CONTRACTOR
<br /> ALL K-PANEL, FRP&MARMOLEUM ARE FURNISHED BY
<br /> OWNER AND INSTALLED BY GENERAL CONTRACTOR
<br /> D2 D3 D4
<br /> 1 GUEST SERVICES FLOOR PLAN 2 GUEST SERVICES REFLECTED CEILING PLAN 3 GUEST SERVICES FINISH PLAN
<br /> A303 SCALE: 1/4" = 1'-0" A303 SCALE: 1/4" = 1'-0" A303 SCALE: 1/4" = 1'-0" D. CURVED FLOORING NODES TO BE PROCURED BY TARGET
<br /> AND CUSTOM MANUFACTURED BY ARMSTRONG FLOORING.
<br /> INSTALL CURVED FLOORING NODES PER SPECIFICATIONS
<br /> AND MANUFACTURER'S INSTALLATION INSTRUCTIONS.
<br /> CONTACT DAVID ROPERTI WITH QUESTIONS AT
<br /> DLROPERTI@ARMSTRONGFLOORING.COM
<br /> E. ALL SALES FLOOR COLUMNS RECEIVE STAINLESS STEEL
<br /> BASE. NO RESILIENT BASE AT COLUMNS, SEE 19
<br /> A502
<br /> F. INSTALL HYDRAULIC CEMENT BASED UNDERLAYMENT
<br /> TO CREATE FEATHERED EDGE AT TRANSITION
<br /> BETWEEN RESILIENT FLOORING AND EXPOSED
<br /> 3 CONCRETE FLOOR ON ALL SIDES.
<br /> G. FLOOR FINISH CHANGES BETWEEN ROOMS OCCUR AT
<br /> DOOR CENTERLINES TYPICAL.SEE A601 FOR ADDITIONAL
<br /> FLOOR FINISH INFORMATION.
<br /> H. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL
<br /> m 17' 11 1/4" CORNER GUARD-VERIFY REUSE OF EXISTING CORNER
<br /> GUARD
<br /> 0 0 °„° ,¢ PWS-1 (5 EQ PANELS)
<br /> Lu 4 ''' '0 01 J. SST CORNER GUARDS AND WALL CAPS TO 4'-0"AFF UNLESS
<br /> A304 i 1"REVEAL, PAINT 1"REVEAL, PAINT Lu 4 Lu A304 WALL PROTECTION IS TO T-2"AFF IN WHICH CASE THE SST
<br /> EXPOSED PLYWOOD
<br /> A304 EQ EQ E EQ EQ _ CORNER GUARD OR WALL CAP WILL TERMINATE AT THE
<br /> EXPOSED PLYWOOD i i
<br /> FLAT BLACK,TYP. FLAT BLACK SAME HEIGHT AS THE WALL PROTECTION.
<br /> B/0 ACT OgL B/0 ACI OgL B/O ACT
<br /> EL=110' 0" EL=110' 0" = EL=110' 0" K. FOR SST CORNER GUARD/VERTICAL SST END CAPS TO
<br /> 6'-7"
<br /> OPEN RB CONNECTION SEE 11
<br /> CLEAR FINISH STEEL BEYOND N A502
<br /> PANEL SIGN BY GC, PIN -1 �❑❑� 0 o b �� [ (❑
<br /> LETTERS BY TARGET ❑��0 0��[ N EQ EQ L. INSTALL REDUCER STRIP(FTS 1A ONO)AT TRANSITION
<br /> IPS-1,C-9 BETWEEN RESILIENT FLOORING AND BROAD LOOM CARPET.
<br /> 1"
<br /> OPU SIGN 1"PROUD M. INSTALL REDUCER STRIP(FTS-2)AT TRANSITION BETWEEN
<br /> OF WOOD CLADDING k RESILIENT FLOORING AND EXPOSED CONCRETE FLOOR ON
<br /> ALL SIDES. PROFESSIONAL OF
<br /> N. DO NOT APPLY ANY SEALANT UNDER CT. RECORD SEAL
<br /> RB-1 A
<br /> P. FOR K-PANEL WALL CAP, CORNER GUARD AND END
<br /> T/0 SLAB OgL T/0 SLAB T/0 SLAB CAP DETAILS SEE
<br /> EL=100'-0" EL=100'-0" EL=100' 0" 10 11 12 17 18
<br /> CLEAR FINISH STEEL RB 1A RB 1A S1 RB-1A CLEAR FINISH STEEL A502 A502 A502 A502 A502 Jill
<br /> END PLATE,TO T/0 WOOD CLADDING PIN LETTERS BY END CORNER GUARD
<br /> WOOD CLADDING WOOD CLADDING USED A RCy��
<br /> K-11 TARGET K-11 TO 4'-0"AFF
<br /> FOR PATTERN,SEE ROBERT J.SARGENTI
<br /> 12 PWS-1 WIDTH TO BE 1/8"REVEAL
<br /> FOR PATTERN,SEE% 13 A304 3-6"MIN/4'-0"MAX. PAINT EXPOSED PLYWOOD
<br /> A304 CLEAR FINISH STEEL FACE OF PANELS FLAT BLACK,TYP.
<br /> CORNER GUARD TO TO ALIGN,SHIM No. C-31054
<br /> T/0 WOOD CLADDING AS REQUIRED 07/31/
<br /> CLEAR FINISH STEEL �j Re
<br /> CORNER GUARD INTERIOR ELEVATION NOTES CA
<br /> TO 4'-0"AFF
<br /> 4 GUEST SERVICES ELEVATION 5 GUEST SERVICES ELEVATION 6 GUEST SERVICES ELEVATION A. CONTROL JOINTS SHOWN ARE SPECIAL
<br /> A303 SCALE: 1/4" = V-0" A303 SCALE: 1/4" = V-0"
<br /> A303 SCALE: 4" _ '-0"
<br /> CONDITIONS ONLY. REFER TO PROJECT MANUAL
<br /> CRITERIA FOR LOCATION AND SPACING OF ALL
<br /> OTHER CONTROL JOINTS
<br /> B. FOR ADDITIONAL FINISH INFORMATION
<br /> SEE ROOM FINISH SCHEDULE-SHEET A601
<br /> C. RB SHOWN AT ALL EXPOSED WALLS AND EXTENDS 6"
<br /> BEHIND FIXTURES RB IS ALSO PLACED IN AREAS WITH
<br /> WC-6 AND AT JEWELRY BOAT FIXTURE
<br /> D. ALL OUTSIDE CORNERS TO RECEIVE STAINLESS STEEL
<br /> CORNER GUARD-VERIFY REUSE OF EXISTING CORNER O
<br /> GUARD
<br /> E. ALL 7-1/4"OR GREATER WALL THICKNESSES TO HAVE(2) Lo
<br /> SEPARATE OUTSIDE STAINLESS CORNER GUARDS. IF
<br /> WALL THICKNESS IS LESS THAN 7-1/4"USE(1) FULL WALL
<br /> THICKNESS STAINLESS STEEL END CAP
<br /> F. PAINT TO EXTEND MIN 6"BEHIND FIXTURES. DO NOT , 1
<br /> SAND OR PAINT GYPSUM BOARD CONSTRUCTION THAT IS v
<br /> CONCEALED BY FIXTURES _
<br /> G. VERIFY FINAL FIXTURE LOCATIONS W/OWNER
<br /> H. FOR CONTROL JOINTS SEE 3 5 v
<br /> A501 A501 TYP
<br /> I. PROVIDE SLIP CONTROL JOINT AT ALL LOCATIONS U
<br /> WHERE ROOF SUPPORTED BULKHEAD ABUTS FLOOR
<br /> SUPPORTED 4 _
<br /> WALL-SEE A501 Q
<br /> TYP
<br /> J. ALL HM DOORS AND FRAMES ON SALES FLOOR TO BE L.L
<br /> PAINTED TO MATCH ADJACENT WALL SURFACE LINO W
<br /> K. ANY EXPOSED WALL SURFACES GREATER THAN OR W
<br /> EQUAL TO 18"ADJACENT TO INTERIOR SALES FLOOR J
<br /> HARDLINES DOOR LOCATIONS TO RECEIVE KYDEX TO A
<br /> HEIGHT OF T-2". KYDEX COLOR SELECTION, K-11 OR
<br /> K-201,TO MATCH ADJACENT WALL SURFACE.
<br /> Z
<br /> REFLECTED CEILING PLAN NOTES o
<br /> A. SEE SHEET A001 FOR SYMBOLS. O
<br /> 00
<br /> B. VERIFY LOCATIONS OF HANGING DEPARTMENT SIGNS N
<br /> WITH TARGET'S IN STORE MARKETING. LOCATIONS
<br /> SHOWN ARE FOR REFERENCE ONLY 6
<br /> A501 S1
<br /> C. ACT CEILING GRIDS ARE CENTERED IN ROOMS PER
<br /> SPECIFICATION 09 5100 CRITERIA UNLESS NOTED
<br /> OTHERWISE
<br /> D. PROVIDE SLIP CONNECTION AT ALL WALLS EXTENDING PROJECT NUMBER: T-0738
<br /> TO ROOF OR STRUCTURE-SEE
<br /> A501
<br /> 8
<br /> TYP CONFIG: LL
<br /> E. PROVIDE QUANTITY AND LOCATION OF DIRECTIONAL/
<br /> EXIT SIGNS AS REQUIRED BY FIRE MARSHAL HAVING DRAWN BY: J.P. RIOS
<br /> JURISDICTION
<br /> F. REFER TO ELECTRICAL/MECHANICAL FOR LIGHT CHECKED BY: G.ABREU-GARCIA
<br /> FIXTURE AND DIFFUSER RELOCATION. COORDINATE
<br /> FOR REMOVAL/REUSE OF LIGHTS, DIFFUSERS AND
<br /> DOOR PAINT GENERAL NOTE
<br /> SPRINKLER HEADS
<br /> G. FOR ALIGNMENT OF SPRINKLER IN SALES FLOOR CEILING GUEST SERVICES
<br /> SEE SPEC, DIV 21
<br /> H. FOR CEILING GRID BRACING AND EDEGE CONDITIONS IN PLANS &
<br /> A. REFER TO ELEVATIONS AND OPENING SCHEDULE FOR HM SEISMIC DESIGN CATEGORY-SEE 2 3 4
<br /> DOOR AND FRAME FINISH INFORMATION. HM DOOR AND A131 A131 A131 ELEVATIONS
<br /> FRAME FINISHES ARE CALLED OUT IN THE OPENING
<br /> SCHEDULE.
<br /> B. HM DOORS AND FRAMES ARE NOT TO BE PAINTED C-100 CEILING LEGEND
<br /> WHITE, TYPICAL.
<br /> (E)ACT NEW ACT
<br /> CEILING CEILING
<br /> (E)GYP BD NEW GYP BD
<br /> CEILING CEILING
<br /> 1/17/2019 5:30:30 PM
<br />
|