My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEMOLITION GENERAL NOTES: <br /> A. ALL EXISTING PIPING INDICATED ON PLAN WAS TAKEN FROM EXISTING <br /> MECHANICAL PLANS AND/OR FIELD OBSERVATION AND SHALL NOT BE <br /> CONSIDERED 100 PERCENT ACCURATE.CONTRACTOR SHALL VERIFY <br /> LOCATION OF ALL EXISTING SYSTEMS PRIOR TO CONSTRUCTION AND <br /> SHALL NOTIFY THE OSR OF ANY POTENTIAL CONFLICTS. <br /> B. CONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL <br /> DRAWINGS,SPECIFICATIONS&EXISTING CONDITIONS FOR BIDDING PURPOSES.NO <br /> ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT <br /> OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br /> C. BELOW SLAB(BURIED)PIPING ABANDONED IN PLACE SHALL BE CAPPED, PLUGGED TARGET® <br /> AND CONCEALED. PLUGGING AND CAPPING SHALL BE DONE IN A MANNER AS TO <br /> ALLOW REOPENING AND REUSE LATER. ABOVE SLAB PIPING SHALL NOT BE 1000 N ICOLLET MALL <br /> ABANDONED IN PLACE; REMOVE PIPING BACK TO MAIN WHERE SHOWN ON PLANS. MINNEAPOLIS, MN 55403 <br /> D. PATCHING OF PENETRATIONS WHERE PIPING IS REMOVED SHALL BE BY <br /> GENERAL CONTRACTOR. <br /> E. CONCRETE CUTS(BY GENERAL CONTRACTOR)SHALL BE STRAIGHT AND <br /> CLEAN. REPLACE SLAB WITH CONCRETE FLUSH AND SMOOTH WITH <br /> 1 1 6 ADJACENT SURFACE. <br /> F. FIELD VERIFY LOCATIONS AND QUANTITY OF ALL EXISTING EQUIPMENT, <br /> FIXTURES AND PIPING NECESSARY TO COMPLETE SCOPE OF WORK. =if MW <br /> _ _ _ _ _ - B _ _ _ _ _ _ _ _ _ _ - K - - i G. ARRANGE ALL REQUIRED WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A <br /> (E)2"V MINIMUM. COORDINATE DISRUPTIONS WITH TARGET OSR AND STORE MANAGER. DC ENGINEERING <br /> (E)1/2"CW (E)3/4"HW i ® I 9 ® (E)�4��HW, I �\ <br /> (E)1/2"R I (E)1/2 I _ b H. j Careful listening. Dynamic solutions. <br /> (E)112-HW- - - INDICATED TO BE REMOVED-ALL REMOVED EQUIPMENT SHALL BE <br /> i C) Em C) ® DISPOSED OF BY CONTRACTOR UNLESS NOTED AS www.d(engineering.net <br /> _ _ _ __ _____ _ ___ (E)1/2"CW RELOCATED/RETAINED IN DEMOLITION PLANS AND/OR KEYNOTES. <br /> fit.E 3/4 HW-- �E 3/4 HW-- Phone:208.288.2181 Project:11 8TAR1 7 <br /> � ( ) ' -- - (E)2"V ( ) " -- VL) PROVIDE OSR&TARGET FACILITIES MANAGEMENT FIRST RIGHT OF <br /> � <br /> i REFUSAL ON REMOVED OR DEMO'ED EQUIPMENT. <br /> FIXTURE J. HALF TONE INDICATES EXISTING CONDITIONS. <br /> E](E) I Li ° 0(E) 1 STORAGE (EX)SW TYP.TEXT OF EXISTING CONDITIONS-CONTRACTOR SHALL <br /> 1 "'f 1 "'f 142 CO�� VERIFY ALL EXISTING CONDITIONS. <br /> V� (E)1 1/4"CW CCTV <br /> O O <br /> (E)2" 0 (E)2„V� <br /> ' (E)1 1/4"CW , 9 F 111A K. SUBMIT(2)COPIES OF REDLINED AS-BUILT UPDATES.ONE COPY SHALL BE <br /> 1 FOOD I ' 13 8RETAINED AT THE STORE. RETURN A SECOND COPY TO THE OSR TO BE <br /> I ' I SERV ' ® O FORWARDED TO THE MECHANICAL ENGINEER. <br /> I STORAGE I I I 1 <br /> j120 ' .JANITOR 1 (E) WH - L. CONTRACTOR SHALL COORDINATE ALL PHASES OF DEMOLITION WITH <br /> I <br /> 1 - 1 IT ❑ 2 {� (EJ2"V- ARCHITECTURAL DEMOLITION PLANS. <br /> 04 <br /> W N W <br /> w - P I�V <br /> ) GENERAL NOTES: <br /> L i C - <br /> HN <br /> F 8 _ A. PITCH UNDERFLOOR SANITARY WASTE AND STORM PIPING 4"AND GREATER AT 1/8"PER <br /> O 13 FOOT, UNLESS NOTED OTHERWISE. PITCH ALL OTHER WASTE PIPING AT 1/4"PER FOOT <br /> 9 (E)112„HW - I UNLESS OTHERWISE NOTED. <br /> •(E)1 1/2"CW -(E)1 1/2" - - B. FIELD VERIFY LOCATION AND INVERTS OF SITE UTILITIES. <br /> - (E)2"CW - - (E)3"CW - - (E)2"CW - ~ (E)3"CW — (E)1/2"HW i <br /> -- — g - - -- - - g 1 C. WASTE AND VENT PIPING BELOW FLOOR AND THROUGH FLOOR SHALL BE 2"MINIMUM. <br /> Alk <br /> D. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS AND ELEVATIONS OF PLUMBING <br /> NIGHT U FIXTURES AND TOP OF FLOOR DRAIN ELEVATIONS. Date No. Description <br /> (E)11/4"HW MAINT 1 , w RESTROOMi <br /> (E)21/2"CWS+ 3 MEN 6 F 6 F 139 ' 143 E. BELOW GRADE PLUMBING HAS BEEN COORDINATED WITH STRUCTURAL FOOTINGS TO 01/17/19 ISSUED FOR PERMIT <br /> PREVENT UNDERMINING OF THE FOOTINGS.ANY CHANGES TO UNDERFLOOR PIPE <br /> ' 116 8H 8 LOCATIONS MUST BE APPROVED BY THE STRUCTURAL ENGINEER. <br /> F. REFER TO STORE EQUIPMENT SCHEDULES ON SHEET P601 FOR INDIVIDUAL BRANCH <br /> ' HWS PIPE SIZES TO FIXTURES AND ROUGH IN REQUIREMENTS. <br /> G. REFER TO SHEET P601 FOR PLUMBING SCHEDULES. <br /> H. SEE SHEET PM01 FOR TYPICAL PIPE HANGER DETAILS. <br /> JANITOR ROOM PLUMBING DEMOLITION PLAN 2 JANITOR ROOM PLUMBING PLAN 3 NIGHT MAINTENANCE PLUMBING PLAN J. SLOPE STORM DRAIN PIPING AT 1/8"PER FOOT UNLESS NOTED OTHERWISE. INSTALL <br /> P301 SCALE: 1/4"=V-0" P301 SCALE: 1/4"= 1'-0" P301 SCALE: 1/4"= V-0' HORIZONTAL AT STORM DRAIN PIPING AS HIGH AS POSSIBLE. <br /> K. PITCH VENT PIPING AT 1/8"PER FOOT TO DRAIN BACK TO WASTE PIPE. <br /> 5 5 L. DIMENSIONS INDICATED ARE TO BE VERIFIED WITH OWNER'S REPRESENTATIVE& <br /> ADJUSTED AS REQUIRED BY EQUIPMENT OR FIELD CONDITIONS. <br /> i M. COORDINATE PIPING INSTALLATION WITH DUCTWORK AND DUCTSOX INSTALLATION ON <br /> B - - - - - - III B _ _ _ _ _ _ _ - - - Tii SHEET M111 IN STOCK AND MARKING AREAS. <br /> i N. ALL DOMESTIC WATER AND VENT PIPING AT STOCK AND MARKING AREAS SHALL BE <br /> ROUTED BETWEEN JOISTS OR THROUGH JOIST WEB. LOCATE BOTTOM OF PIPING IN <br /> STOCK AND MARKING AT MINIMUM 16-0"AFF. <br /> LOUNGE 0. SEE DETAILS 2/P601,3/P601 AND 4/P601 FOR PIPE BRACING REQUIREMENTS. <br /> WH 1 <br /> WH (E) 3 P601 5 157 KEYNOTES: <br /> 2"VENT UP 10 <br /> 4 TO 4"VTR EXISTING TO REMAIN. <br /> ° - � �—- - (E)1 1/2"V - - -- --- - - -�(� �--- - -- - (E)1 1/2"V --- ---- 2❑ REMOVE EXISTING INSTANTANEOUS WATER HEATER. EXISTING ROUGH INS TO REMAIN. <br /> U <br /> I w � � I 3❑ REMOVE WATER COOLER IN ITS ENTIRETY. EXISTING ROUGH-INS TO REMAIN. <br /> 2"VENT UP � F <br /> 1 I I 7 <br /> 7 <br /> TO 4"VTR I I ® REMOVE EXISTING LOUNGE SINK.EXISTING ROUGH-INS TO REMAIN. <br /> co <br /> u' 5❑ CONNECT NEW INSTANTANEOUS WATER HEATER TO EXISTING PIPING. MODIFY AS <br /> I I REQUIRED. 1/2"COLD WATER TO SINK AND INSTANTANEOUS WATER HEATER UNDER <br /> I I SINK. 1/2"HOT WATER FROM WATER HEATER TO SINK. PROVIDE SHUTOFF VALVE ON <br /> I I COLD WATER TO WATER HEATER UNDER SINK. <br /> I I <br /> INSTALL NEW WATER COOLERS USING EXISTING ROUGH-INS.MODIFY OR ADD PIPING AS <br /> I I <br /> REQUIRED. <br /> I I <br /> I I 7❑ <br /> -(E)1/2"CW - -(E)1/2"CW - INSTALL NEW LOUNGE SINK USING EXISTING ROUGH-INS.MODIFY PIPING AS REQUIRED. <br /> - I iI i <br /> ROUTE WATER AND SANITARY LINES TIGHT TO BACK OF CABINET AND INSULATE FOR <br /> ADA INSTALLATION.SEE SPECIFICATIONS. <br /> CIRCULATION ® 1/2"COLD WATER AND 1/2"HOT WATER DOWN IN WALL TO EYEWASH. PROVIDE <br /> EMERGENCY THERMOSTATIC MIXING VALVE SET TO 70°F.CONNECT TEMPERED HOT <br /> 10 3 108 F F WATER LINE FROM THERMOSTATIC MIXING VALVE TO EYEWASH STATION PER EYEWASH QROFESS/ <br /> 10 g 0 gH I STATION MANUFACTURERS REQUIREMENTS. ROUTE INDIRECT WASTE TO JANITORS � �0 H. <br /> SINK. PROVIDE AHJ APPROVED AIR GAP. Z . <br /> m <br /> 4 LOUNGE PLUMBING DEMOLITION PLAN 5 LOUNGE PLUMBING PLAN9� CONNECTNEW PIPING TOEXISTING PIPING.VERIFY SIZE AND LOCATION. 31885 <br /> P301 SCALE: 1/4"=V-0" P301 SCALE: 1/4"= V-0" P: 12/31/19 <br /> 10 CONTRACTOR TO VERIFY IF TWO WATER COOLERS EXIST. IF TWO EXIST,REPLACE <br /> BOTH IN PLACE. IF ONLY ONE WATER COOLER EXISTS, REPLACE EXISTING WITH NEW `r� ��CHAN\Gp���P <br /> AND ADD AN ADDITIONAL WATER COOLER AS SHOWN IN 5/P301.ADJUST/MODIFY PIPING 9TFOF CAS\F�� <br /> TO ACCOMMODATE FOR TWO WATER COOLERS IF REQUIRED. <br /> DATE: 01/17/2019 EXP: 12/31/2019 <br /> coUJL0 <br /> Q <br /> U <br /> U <br /> Q <br /> U °C <br /> Q <br /> I— <br /> OC � <br /> o� <br /> LL, <br /> PEILU <br /> _J <br /> C� <br /> Q <br /> z <br /> 0 <br /> 0 <br /> co <br /> N <br /> Project Number T-0738 <br /> Config: LL <br /> Drawn By B. SMEAD <br /> Checked By J. HAM M <br /> JANITOR, NIGHT <br /> MAINTENANCE, & <br /> LOUNGE PLUMBING <br /> PLANS <br /> PLAN NORTH <br /> 1/17/2019 1 :22:55 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.