PLUMBING EQUIPMENT RESPONSIBILITY MATRIX <br /> DELIVERY TESTING& <br /> ELECTRICAL EQUIPMENT SCHEDULE BALANCING OF <br /> EQUIPMENT SPECIFIED MFR FURNISH BY INSTALL BY CONNECTION START UP COORDINATION EQUIPMENT REMARKS <br /> WATER HEATER WH-3 CHRONOMITE PLBG CONTR PLBG CONTR ELEC PLBG CONTR PLBG CONTR NOT REQUIRED <br /> PLUMBING FIXTURES VARIES OWNER PLBG CONTR ELEC IF POWER PLBG CONTR PLBG CONTR PLBG CONTR M1 1 <br /> P3000 UNISTRUT F8, F8H REQ'D <br /> CLIP ENDS TO JOIST PLUMBING FIXTURES VARIES PLBG CONTR& PLBG CONTR --- PLBG CONTR PLBG CONTR PLBG CONTR OWNER FURNISHES SINK AND FAUCET, PLBG CONTRACTOR PROVIDES TRIM AND AERATOR. M2 <br /> F7 OWNER <br /> JOIST TOP CHORD PLUMBING FIXTURES GUARDIAN PLBG CONTR PLBG CONTR --- PLBG CONTR PLBG CONTR PLBG CONTR <br /> � OR BEAM FLANGE F13 TARGET® <br /> 1/2" HW 1/2" CW <br /> TO TO LONGITUDINAL BRACE 1000 N ICOLLET MALL <br /> FAUCET FAUCET SEE SCHEDULE MINNEAPOLIS, MN 55403 <br /> = U 1 1 4 ROD HANGER& <br /> MOUNTING VERTICAL ANGLE <br /> FLANGE BEAM ATTACHMENT PLUMBING FIXTURE SCHEDULE - NEW <br /> (TYP. OF 4) 1/8"FILLET WELD FURNISHED BY <br /> FIXT NO. TYPE WASTE VENT CW HW CONTR OWNER REMARKS <br /> ? — FOR PIPE SIZE SEE SCHEDULE F-7 LOUNGE 1 1/2" 1 1/2" 1/2" 1/2" Yes Yes M2 PROVIDE 0.5 GPM AERATOR. FLOW RATE:0.5 GPM.SINK AND FAUCET ARE FURNISHED BY OWNER,CONTRACTOR PROVIDES TRIM AND <br /> SINK AERATOR. <br /> C� PIPE CLAMP F-8 ELEC WATER 1 1/2" 1 1/2" 1/2" --- No YesWALL HUNG. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. <br /> COOLER <br /> F-81-1 ELEC WATER 1 1/2" 11/2" 1/2" --- No Yes WALL HUNG. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. <br /> COOLER DC ENGINEERING <br /> NOTE: F-13 PLUMBED 1 1/2" --- 1/2" 1/2" Yes No WALL HUNG. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT. DRAIN INDIRECTLY INTO ADJACENT MOP SINK.PROVIDE WITH <br /> C� 1/2" CW 3/4" CW LONGITUDINAL BRACING AT 80'-0"OC MAX., UNLESS NOTED. EYEWASH ASSE 1071 EMERGENCY THERMOSTATIC MIXING VALVE. SLOAN TA-300-LF OR EQUIVILENT. Careful listening Dynamic solutions.o 011/2" <br /> SPACING FOR 10"AND 12"IS 24'OC. <br /> www.dcengineering.net <br /> SHUTOFF VALVE THIS BRACING DETAIL APPLIES ONLY FOR COLD WATER PIPE&GAS PIPE WHERE Phone:208.288.2181 Project:l8TAR17 <br /> COMPRESSION FITTING MOVEMENT OF THE PIPE DUE TO TEMPERATURE DIFFERENTIAL IS NEGLIGIBLE. <br /> INSTANTANEOUS (TYP. OF 2) WHEN THERMAL EXPANSION OR CONTRACTION IS INVOLVED, PROVIDE LONGITUDINAL BRACES <br /> ELECTRIC AT ANCHOR POINTS. THE LONGITUDINAL BRACES AND THE CONNECTIONS MUST BE CAPABLE OF WATER HEATER SC H E D U L E - NEW <br /> WATER HEATER RESISTING THE FORCE INDUCED BY EXPANSION AND CONTRACTION. <br /> ELECTRICAL DATA <br /> 1 INSTANTANEOUS WATER HEATER 2 LONGITUDINAL PIPE BRACING INPUT <br /> ELECTRIC <br /> P601 SCALE: NOT TO SCALE P601 SCALE: NOT TO SCALE <br /> TEMP GAL/HR STORAGE NUMBER OF HEAT COIL(W TOTAL <br /> TAG NO. AREA SERVED LOCATION MANUFACTURER MODEL RISE(F) RECOVERY (GAL) VOLTAGE PHASE HZ HEATING COILS EACH) kW REMARKS <br /> WH 3 LOUNGE SINK LOUNGE-157 EEMAX SPEX60T EE 41 1 0.0 277 1 60 1 6000 6.0 ELECTRONIC TANKLESS WATER HEATER;UNLIMITED HOT WATER,99%ENERGY <br /> EFFICIENT, MEETS ALL CL GREEN LOW FLOW REQUIREMENTS,VANDAL RESISTANT, <br /> COMPACT SIZE, MEETS ADA,UL, IAPMO,UPS, CSA. REFER TO MANUFACTURERS <br /> SPECIFICATIONS.0.8 GPM AT 47 DEGREE F TEMP RISE. <br /> PIPE BRACING SCHEDULE <br /> PIPE HANGER DIAGONAL BRACE LONGITUDINAL TOP CONN OF ROD MAXIMUM <br /> P3000 UNISTRUT SIZE TYPE &OR VERTICAL BRACE DIAG&LONG SIZE LENGTH <br /> CLIP ENDS TO JOIST ANGLE ANGLES FOR RODS VACUUM PUMP SCHEDULE - EXISTING <br /> UP TO CLEVIS 2"X2"X16 GA 2 1/2"X2 1/2"X16 GA 1/2"LAG BOLT 1/2" 25" <br /> JOIST TOP CHORD 2" #OF LIFTS ELECTRICAL <br /> OR BEAM FLANGE 21/2" CLEVIS 2"X2"X16 GA 2 1/2"X2 1/2"X16 GA 3/4"MACH BOLT 1/2" 25" TAG NO. DESCRIPTION LOCATION MANUFACTURER MODEL KITS VOLTAGE PHASE FLA REMARKS Date No. Description <br /> ADD VERTICAL ANGLE FROM SCHEDULE WHEN CV 1 CONDENSATE VACUUM PUMP ROOM ACORNVAC AV-30S-2.3-L 29 208 3 15.4 EXISTING TO REMAIN.28 EXISTING ACCUMULATORS TO REMAIN.2 ACCUMULATORS TO BE 01/17/19 ISSUED FOR PERMIT <br /> VACUUM SKID 185 R-SE-MOD RECONNECTED TO NEW CASES. 1 NEW ACCUMULATOR FOR NEW CASE.29 TOTAL <br /> ROD GREATER THAN MAXIMUM ALLOWED. 3" CLEVIS 2"X2"X16 GA 2 1/2"X21/2"X16 GA 3/4"MACH BOLT 1/2" 25" ACCUMULATORS. <br /> PROVIDE AT 10"AND 12"FOR ALL APPLICATIONS. <br /> HANGER ROD AND ANGLE 31/2" CLEVIS 2"X2"X16 GA 2 1/2"X21/2"X16 GA 3/4"MACH BOLT 1/2" 25" <br /> SEE SCHEDULE <br /> 1/8"GROOVE WELD- <br /> 4" CLEVIS 2"X2"X16 GA 2 1/2"X2 1/2"X16 GA <br /> 3/4 MACH BOLT 5/8" 31 <br /> L g;N <br /> DIAGONAL BRACE <br /> 1"LONG/24"OC 5" CLEVIS 2"X2"X16 GA 2 1/2"X2 1/2"X16 GA 3/4"MACH BOLT 5/8" 31" <br /> SEE SCHEDULE <br /> PIPE SIZE SEE SCHEDULE 6" CLEVIS 2 1/2"X21/2"X16 GA 2 1/2"X21/2"X16 GA 3/4"MACH BOLT 3/4" 37" <br /> COPE LEG OF ANGLE 8" CLEVIS 2 1/2"X21/2"X16 GA 2 1/2"X21/2"X16 GA 3/4"MACH BOLT 7/8" 43" <br /> HANGER ROD CLIP 10" CLEVIS 3"X3"X3/16" 3"X3"X3/16" 3/4"MACH BOLT 7/8" N/A <br /> 12" CLEVIS 3"X3"X3/16" 3"X3"X3/16" 3/4"MACH BOLT 7/8" N/A <br /> NOTE: <br /> INSTALL TRANSVERSE PIPE BRACING ON <br /> NOTES: 1.SCHEDULE APPLIES TO WATER(&SPRINKLER <br /> ALL INTERIOR PIPING EXCEEDING 30 FEET ( ) PIPES 2"AND LARGER <br /> IN LENGTH. MAX SPACING IS 40 FEET OC. 2.SCHEDULE APPLIES TO FUEL(GAS)PIPES 1"AND LARGER <br /> MAX SPACING FOR 10"AND 12"IS 12 FEET OC. 3.SCHEDULE APPLIES TO RWC PIPES 10"AND LARGER <br /> 3 TRANSVERSE PIPE BRACING 4 PIPE BRACING SCHEDULE <br /> P601 SCALE: NOT TO SCALE P601 SCALE: NOT TO SCALE <br /> QRpFESSH. <br /> / <br /> CO <br /> 31885 <br /> P: 12/31/19 <br /> —HAN\OP��\P <br /> qTF <br /> FC <br /> DATE: 01/17/2019 EXP: 12/31/2019 <br /> coUJL0 <br /> Q <br /> U <br /> U <br /> Q <br /> U °C <br /> Q <br /> OC � <br /> o� <br /> LU <br /> PEILU <br /> -i <br /> C� <br /> Q <br /> z <br /> 0 <br /> 0 <br /> 00 <br /> N <br /> Project Number T-0738 <br /> Config: LL <br /> Drawn By B. SMEAD <br /> Checked By J. HAM M <br /> PLUMBING <br /> SCHEDULES & <br /> DETAILS <br /> P601 <br /> 1/17/2019 1 :23:02 PM <br />