My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9 10 11 <br /> 9 10 11 9 10 <br /> I GENERAL NOTES: <br /> I I I I <br /> 3' 4" I A. REFRIGERATION CONTRACTOR SHALL RECEIVE, UNLOAD SET, ALIGN, <br /> I 3 I AND LEVEL CASES INCLUDING THE JOINING OF CASES, INSTALLATION OF <br /> END PANELS, COVER PLATES AND TRIM STRIPS IN ACCORDANCE WITH <br /> (N MANUFACTURER'S INSTRUCTIONS. <br /> (N) 10 B07 (E) ACC O O B. INSTALL RUNNING TRAP ON ALL CASES. CASE CONDENSATE LINE SIZE <br /> B07 I 1-CU SHALL MATCH THE SIZE OF THE CONDENSATE TRAP FOR EACH CASE. <br /> a ROUTE CONDENSATE DRAIN PIPING UNDER CASES TO HUB DRAIN. <br /> Cl) 3 PROVIDE A 1"AIR GAP AT DRAIN. SEE PLUMBING DRAWINGS FOR TARGETg 44I z DETAILS, SEE CONDENSATE SCOPE SCHEDULE. <br /> 14 z z I O O C. INSTALL CASE MANUFACTURER FURNISHED TRIM PIECES ON ALL CASES. 1000 NICOLLET MALL <br /> F I F D. REFRIGERATION CONTRACTOR TO VERIFY THE LOCATION OF OWNER MINNEAPOLIS, MN 55403 <br /> F - - - - - - - - - - - - - - - - - - - - - - - F F - I- - - - - - - - - F INSTALLED FILLER BOXES ON THE STORE PLANNING FIXTURE PLAN. CASE <br /> TRIM IS NOT REQUIRED BETWEEN THE CASE AND THE FILLER BOX. <br /> E. INSTALL RC SUPPLIED ENGRAVED PLASTIC LAMINATE SIGN TO EACH <br /> (E) CASE, ADJACENT TO MANUFACTURERS MODEL AND SERIAL NUMBER TAG <br /> (E) B07 ON INTERIOR SURFACE OF CASE INDICATING REFRIGERATION SYSTEM <br /> 807 AND TEMPERATURE SENSOR NUMBER. (EXAMPLE, THE CASE CONTAINING <br /> THE FIRST CONTROL TEMPERATURE SENSOR OF CIRCUIT A01 WOULD BE <br /> "A01 T1"). RC TO FURNISH SIGN FROM MARKING SERVICE INC. PH: (800) — <br /> � <br /> 234-0135. <br /> LU DC ENGINEERING <br /> L, p C/) KEYNOTES: <br /> w <br /> w Careful listening. Dynamic solutions. <br /> W� 1❑ EXISTING REMS-3 PANEL TO REMAIN. WWW.d[Bl191l18ErIl19.IlEf <br /> Phone-208.288.2181 Project:18XX01 <br /> (E) 2❑ EXISTING REMS-4 PANEL TO REMAIN. <br /> (E) I 807 <br /> (E) �3 INSTALL CASE MANUFACTURER FURNISHED TRIM PIECES ON ALL CASES. <br /> SEE DETAILS 13/R511, 14/R511 AND 15/R511. <br /> ® ROUTE CONDENSATE DRAIN PIPING UNDER CASES TO VACUUM <br /> ACCUMULATOR. SEE PLUMBING DRAWINGS FOR DETAILS. <br /> I I <br /> z p ❑5 IF SEAL FOR FAN KIT IS COMPROMISED BY INSTALLATION OF NEW CASE <br /> <r p Z cW CONTRACTOR TO REPAIR TO EXISTING CONDITION. <br /> W <br /> zp <br /> � W� © CAP AND ABANDON HOT GAS PIPING FOR SYSTEMS BA01 AND BA02 AT <br /> w w 5 RACK. RETAIN AND REUSE LIQUID AND SUCTION LINES. <br /> R401 7❑ CONNECT NEW BA02 CASE TO EXISTING 5/8" SUCTION, 5/8" LIQUID AND <br /> EXISTING 1/2" SUCTION RISER LINES. CAP AND ABANDON 3/8" SECTION <br /> OF THE DOUBLE SUCTION RISER OF SYSTEM AB02. NEW CASE TO RUN <br /> A06-SA06-L AS MEDIUM TEMP AND NOT DUAL TEMP. <br /> A05-S l06-L (E) I <br /> 8 CONNECT NEW BA01 CASE TO EXISTING 5/8" SUCTION, 5/8" LIQUID AND <br /> (E) YAB0AB07-S 1808-L A06 I RTC EXISTING 1/2" SUCTION RISER LINES. CAP AND ABANDON 3/8" SECTION <br /> A06 A01-S A01-L (E) EXISTING <br /> OF THE DOUBLE SUCTION RISER OF SYSTEM AB01. NEW CASE TO RUN <br /> A01-L I AS MEDIUM TEMP AND NOT DUAL TEMP. <br /> A 306-S AB06-L <br /> A805-S A805-L p I 9❑ EXTEND PIPING FROM EXISTING CIRCUIT B07 TO NEW CASE. <br /> U. LLJ <br /> CZ7 p Z <br /> I 10 INSTALL CASE MANUFACTURER FURNISHED FAN BLOWER KIT BETWEEN <br /> Z j I W w� CASE AND WALL. SEE DETAILS 12/R511, 13/R511, AND 15/R511. <br /> _ _ _ _ _ _ _ _ - _ _ _ _LU <br /> _ E 11 INSTALL CASE MANUFACTURER FURNISHED PLEXIGLASS PARTITION Date No. Description <br /> E - - - - - - - - - - - - - - - - - - - - - - - - - - E E - - - - - - + _ E BETWEEN CASES. 01/17/2019 PERMIT ISSUEp <br /> (E) I I <br /> A06 z (E) N5FGN2A 12 REMOVE THE EXISTING EEPR VALVE FOR B01 LOCATED AT RTCR. <br /> p I REUSED (E) <br /> U_ LU IZ � O J J J J J J J J A06 13 14SR511LAND 15/R51 <br /> R5 1E ON TOP OF MARKET CASE. SEE DETAIL 13/R511, <br /> W w m O 0 0 NO N M <br /> O O O O <br /> �z I Q ¢ Q ¢ Q m Q Q m 14 CONNECT TO EXISTING CASE. - <br /> ov) �? cn � CnC� � (E) <br /> (E) I m0000 � 000 (E) N5FGN5A A05 <br /> A05 (E) QQQQQmQQm REUSED <br /> (E) A810 a z p 9 10 CALGREEN CODE: <br /> N EpLU <br /> A810 N p z � J (E) N5FGN5A <br /> z a� w (E) N5FGN5A (E) (E) REUSED W w <br /> � (E) N5FGN5A (E) N5FGN5A E (E) N5FGN5A W (E) I I -z 5.508.2.1 REFRIGERANT PIPING. PIPING COMPLIANT WITH THE CALIFORNIA <br /> LU w p REUSED A04 A04 Cl) 3 R401 - RTCR-1 ROOF PLAN <br /> W W (E) REUSED I A04 REUSED AO REUSED W A04 _ _ J MECHANICAL CODE SHALL BE INSTALLED TO BE ACCESSIBLE FOR LEAK <br /> p A04 Cl) p R401 SCALE: 3/16"=1'0" PROTECTION AND REPAIRS. PIPING RUNS USING THREADED PIPE, COPPER <br /> ? I / I W w TUBING WITH AN OUTSIDE DIAMTER (OD) LESS THAT 1/4 INCH, FLARED <br /> IV/ c� c� Cp `-� TUBING CONNECTIONS AND SHORT RADIUS ELBOWS SHALL NOT BE USED <br /> LU <br /> W L6 6 �? r, oo (E) IN REFRIGERANT SYSTEMS EXCEPT AS NOTED BELOW. <br /> V (E) I r00000000mo A05 <br /> I I A05 ¢ Q ¢ Q Q m 5.508.2.1.1 THREADED PIPE. THREADED CONNECTIONS ARE PERMITTED AT <br /> L6 o J J J J 9 10 THE COMPRESSOR RACK. <br /> 1 I oo � oCO <br /> I REMS-3 Q Q Q Q Q °p E��r - 5.508.2.1.2 COPPER PIPE. COPPER TUBING WITH AN OD LESS THAN 1/4 INCH - <br /> (E) - (E) I (E) A808 MAY BE USED IN SYSTEMS WITH A REFRIGERANT CHARGE OF 5 POUNDS <br /> r(E) (E) (E) (E) A03 (E) A 03 N p OR LESS. _ <br /> A03 A03 A03 A808 a ` A03 Z w <br /> (E) N E p A809 a (E) RLNS 0 (E) RLN5 (E) RLN5 I_ � _ - _ - - - - _ 5.508.2.1.2.1 ANCHORAGE. 1/4 INCH OD TUBING SHALL BE SECURELY <br /> A809 E RLN5 E RLN5 E RLN5 w N p RE �A809-SAB09-L REUSED REUSED p CLAMPED TO A RIGID BASE TO KEEP VIBRATION LEVELS BELOW 8 MILS. <br /> a <br /> O O v, z w I -� � w <br /> N E p REUSED I REUSED I REUSED z p _I f cn 03-S 03-L W p <br /> cwi� W p W Q -(€}RL-Alo A02- A02-L (E) RLN5 (E) RLN5 6 5.508.2.1.3 FLARED TUBING CONNECTIONS. DOUBLE-FLARED TUBING <br /> p (E) RLN5 I (E)RLN5 I (E) RLN5 REUSED (E) (E) REUSED (E) REUSED R401 CONNECTIONS MAY BE USED FOR PRESSURE CONTROLS, VALVE PILOT <br /> �-p REUSED REUSED REUSED �: 1 11 A02 LINES AND OIL. <br /> (E) (E) (E) A02 A02 (E) EXCEPTIONS: SINGLE-FLARED TUBING CONNECTIONS MAY BE USED <br /> A02 A02 A02 (E) GEE) I WITH A MULTIRING SEAL COATED WITH INDUSTRIAL SEALANT <br /> A807 SUITABLE FOR USE WITH REFRIGERANTS AND TIGHTENED IN <br /> JJJJ ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br /> V <br /> L-,,/L ¢ m aop Q Z O 5.508.2.1.4 ELBOWS. SHORT RADIUS ELBOWS ARE ONLY PERMITTED WHERE <br /> z EE p I �¢vm j SPACED LIMITATIONS PROHIBIT USE OF LONG RADIUS ELBOWS. <br /> I I J � (wj) N M g P W � w <br /> W ¢ m m ¢ �p RTC 5.508.2.5 PRESSURE TESTING. THE SYSTEM SHALL BE PRESSURE TESTED <br /> (E) DURING INSTALLATION PRIOR TO EVACUATION AND CHARGING. <br /> (E) (E) (E) (E) I 2 I <br /> D � 3 (E) (E) (E) (E) D (E) 'A603 (E) A804 A805 A806 (E) 5.508.2.5.2 LEAKS. CHECK THE SYSTEM FOR LEAKS, REPAIR ANY LEAKS, <br /> co Dual-Temp Dual-Temp E RLNS <br /> (E) RLNS I ( ) <br /> 'A80 '!804' A805 A806 (E) REUSED REUSED Dual-Tem BOF) AND RETEST FOR PRESSURE USING THE SAME GAUGE. <br /> (E) RLN4 (E) RLN4 2 (E) RLN3 I (E)RLN3 806 ❑ REUSED p REUSED p <br /> ro <br /> Dual-Temp Dual-Tem Dual-Tem Dual-Temp o _ <br /> e z p REMS-4 - 5.508.2.5.3 ALLOWABLE PRESSURE CHANGE. THE SYSTEM SHALL STAND, <br /> Ln REUSED REUSED REUSED REUSED <br /> 4 o z' M UNALTERED FOR 24 HOURS WITH NO MORE THAN A+/-ONE POUND <br /> (N)" (E) 05M-12 (E) (E) 05M-12 (E) (E) 05M-8 (E) (E) 05M-8 O PRESSURE CHANGE FROM 300 PSIG, MEASURED THE SAME GAUGE. <br /> (N) z (E) (E) 05M-12 (E) 05M-12 (E) (E) 05M-8 (E) (E) z BA02 REUSED 804 REUSED 804 REUSED O REUSED / <br /> BA02 804 REUSED REUSED 804 REUSED 805 805 (REU0SED8 p 805 805 W LU <br /> � <br /> W 7 L 803-S �. 804-L QFLOFESS/p <br /> 803-L 807-L 804-St _ 0 M/ <br /> 3 5 807-S ; (E) H. <br /> A01-S- m . <br /> (E) 803 <br /> 3'-4" 11'-4" 803 /�/ 31885 <br /> //�A01-L P: 12/31/19 <br /> I I �/ p sT�F�OF CALF P <br /> p (E) (E) LU <br /> LU <br /> (E) I (E) � A01-C A01-A. W W <br /> A01-C A01-A W (E) OWIZ-8 �"� <br /> N I (E) OWIZ-8 W I D o (E)REUSED p <br /> W Q REUSEDco <br /> O (E) A01-8 zLLJ <br /> DATE: 01/17/2019 <br /> W� I A01-8 (E) 41 <br /> -`w <br /> WLU <br /> I 803 802-L 801-S 805 S 806-L - C - - I - - - - - - - - - - - C <br /> 802-S 805-L <br /> Q I I <br /> E <br /> Z <br /> =03 <br /> E ACC Op pO <br /> 3'-4" 11'-4" 11 Z Z) ( ) 2CU <br /> 3 I W� <br /> (N) -(E)- I -(E)— (E) (E) <br /> BA01 <br /> (N) (E) I (E) (E) (E) 801-A 13 801-8 13 802 802 O <br /> BA0101 (E) 05M-12 (E) 05M-12 (E) 05M-8 0 (E) 05M-8 0 <br /> co (E) 05M-12 801-A (E) 05M-12 601-B (E) 05M-8 802 (E) 05M-8 802 REUSED I REUSED REUSED REUSED <br /> 3 z REUSED I REUSED REUSED REUSED I o BA01-S BA01-L <br /> B o <br /> z 8 I I <br /> — — — — — — — — - - <br /> — — — — — — — — (, <br /> C — — — — — — — — — — — — — — — - - — — — — — — — — — C I <br /> O <br /> 9 10 11 Co <br /> 9 10 11 9 10 <br /> - ^ W <br /> R401 - MARKET AREA CASE SETTING PLAN R401 ' R401 - MARKET AREA PIPING PLAN W Q <br /> 1 SCALE: 3/16"=1'-0" 4 R401 - RTCR-2 ROOF PLAN J <br /> R401 SCALE: 3/16"=1'-0" <br /> R401 SCALE: 3/16"=1'-0" C) <br /> V <br /> Q U <br /> Z Q <br /> C:) <br /> co <br /> A06-S N <br /> A06-L <br /> A05-S <br /> A05-L <br /> AB08-S <br /> AB08-L <br /> AB07-S <br /> AB07-L <br /> A01-S B03-L <br /> A01-L B03-S <br /> AB06-S 12 -B01 <br /> -L <br /> AB06-L B01-S <br /> AB05-S B02-L <br /> AB05-L B02-S <br /> AB 10-S —B05-L <br /> AB 10-L B05-S <br /> A04-S B06-L <br /> A04-L— B06-S <br /> AB09-S B04-L Project Number T-0738 <br /> AB09-L B04-S <br /> A03-S— B07-L i <br /> A03-LConfig: LL <br /> A02-S <br /> CONDENSATE SCOPE SCHEDULE A02-L <br /> BA02-S Drawn By K. Snyder <br /> MANUFACTURER REFRIGERATION CONTRACTOR <br /> BA02-L <br /> AB03-S <br /> Checked By M. Perrodin <br /> HUSSMANN FURNISHED P-TRAP PROVIDE CONDENSATE PIPING, ROUTE TO AB03-L 6 R401 - RTCR-2 HEADER LAYOUT <br /> VACUUM ACCUMULATOR AB04-S <br /> AB04-L R401 NOT TO SCALE <br /> u ' BA01-L MARKET AREA CASE <br /> REFRIGERATION CASE INTERIOR AND EXTERIOR FINISH SCHEDULE SETTING & PIPING <br /> REACH-INS (DOORED CASES) OPEN MULTIDECK-MEAT CASES OPEN MULTIDECK- PRODUCE BEVERAGE OPEN CASES <br /> EXTERIOR INTERIOR EXTERIOR TINTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR 5 NOT - RTCR-1 HEADER LAYOUT PLANS <br /> R401 NOT TO SCALE <br /> NOTES: <br /> 1. ALL NEW SALES FLOOR CASES SHALL MATCH THE INTERIOR OF REUSED CASES. <br /> ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. R4 1 <br /> PLAN NORTH <br /> 1/17/2019 10:02:20 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.