Laserfiche WebLink
SEE 4/R511 FOR DETAILS <br /> ROOF DECK ON CONNECTING THE <br /> BAR JOIST ___ THREADED ROD TO THE <br /> PIPING FROM ROOFTOP ------------- f f' —_ REFRIGERATION <br /> PROVIDE JACKET TO PROTECT ATTACHED TO STRUCTURE ABOVE. THREADED ROD <br /> f f , EXPOSED INSULATED PIPING BOTTOM CHORD PIPES PIPE INSULATION <br /> COMPRESSOR RACK ANDCONDENSER UNIT ON ROOF IN ACCORD WITH OF JOIST <br /> f\\\ SPECIFICATIONS BEAM CLAMP TYPICAL <br /> INVERTED TRAP REQUIRED 3/8" "ALL-THREAD" REFRIGERANT <br /> AT TOP OF SUCTION RISER HANGER ROD 2"x6" METAL PIPING LINE <br /> STUD CUT TO <br /> SEAL PENETRATIONS 3/8" FLEXIBLE O o a c LENGTH <br /> AT PIPE BOX AND ELASTOMERIC <br /> ROOF DECK. PIPE BOX, INSULATION, IN ACCORD 1 5/8" UNISTRUT <br /> SEE ARCHITECTURAL WITH SPECIFICATION 24 SUPPORT TARGET® <br /> DRAWINGS 0719, GLUE TO METAL <br /> STUD (TYPICAL) UNISTRUT <br /> ROOF 3/8" NUT HANGER <br /> INSTALL INTERMEDIATE 3/8"WASHER 1000 NICOLLET MALL <br /> SUCTION LINE P-TRAP ABOVE (TYPICAL) MINNEAPOLIS, MN 55403 <br /> INSULATE REFRIGERATION CEILING IF RISER IS ABOVE <br /> LINES IN ACCORD WITH 15-0" HIGH 2"x6" METAL GENERAL NOTES: GENERAL NOTES: <br /> THE SPECIFICATIONS AND STUD <br /> INSUGUARD OR <br /> INSULATE THE NON- 3/8"WASHER A. ALL HANGERS AND HANGER SUPPORT A. ALL HANGERS AND HANGER SUPPORT SHALL COOPER B-LINE SNAP 'N <br /> INSULATED LIQUID LINES 2 -3/8" NUTS SHALL COMPLY WITH REQUIREMENTS OF COMPLY WITH REQUIREMENTS OF LOCAL CODE SHIELD 12" HORIZONTAL <br /> FROM A POINT 6" OUTSIDE LOCAL CODE AUTHORITIES. AUTHORITIES. PIPE SUPPORTS <br /> OF THE PIPE BOX AND TOA PROVIDE DOUBLE SUCTION 1 5/8" UNISTRUT <br /> POINT 6" BELOW THE ROOF CEILINGS RISER WHERE NOTED ON <br /> OF THE DECK. USE 3/8" / PLANS, SEE DETAIL 8/R511 END VIEW B. NOTE: B. NOTE: <br /> WALL THICKNESS _ROOF DECK_ -AVERAGE PIPE SIZE = 1" -AVERAGE PIPE SIZE = 1" — <br /> INSULATION. -AVERAGE PIPE WEIGHT = 1 PLF F <br /> -AVERAGE PIPE WEIGHT= 1 PL <br /> MAX 6" BEAM CLAMP SHALL - MAX NO. OF PIPES PER HANGER= 20 - MAX NO. OF PIPES PER HANGER= 20 D C ENGINEERING <br /> SUCTION AND - -TOTAL MAX WEIGHT= 100 LBS PER HANGER -TOTAL MAX WEIGHT = 100 LBS PER HANGER <br /> LIQUID LINE ON BE ATTACHED WITHIN UNLESS APPROVED BY STRUCTURAL UNLESS APPROVED BY STRUCTURAL <br /> 6" OF THE BAR JOIST Careful listening Dynamic solutions. <br /> TOP OF CASE ENGINEER ENGINEER 9� Y <br /> PANEL POINT. - BRACING NOT REQUIRED FOR PIPING 3" - BRACING NOT REQUIRED FOR PIPING 3" www.diengineering.net <br /> �— SMALLER SMALLER <br /> REFRIGERATION PIPING IN - 3/8" "ALL-THREAD" Phone-.208.288.2181 Project:18XX01 <br /> WALL OR FALSE COLUMN. SUCTION AND LIQUID LINE HANGER ROD C. SEE 5/R511 FOR ALTERNATE DETAIL C. SEE 4/R511 FOR ALTERNATE DETAIL <br /> P-TRAP REQUIRED AT V CONNECTION D. VERIFY EXISTING BRIDGING REQUIREMENTS D. VERIFY EXISTING BRIDGING REQUIREMENTS <br /> BASE OF SUCTION AT TOP OF CASE PER STRUCTURAL DRAWINGS. PER STRUCTURAL DRAWINGS. <br /> LINE. <br /> 1 ` NOT USED 2 NOT USED _3 REFRIGERATION PIPING RISER 4 REFRIGERATION PIPE HANGER DETAIL 5, REFRIG. PIPE HANGER DETAIL ALTERNATE <br /> R511� R511 R511 NOT TO SCALE R511 NOT TO SCALE R511 NOT TO SCALE <br /> PROVIDE JACKET TO PROTECT EXPOSED PROVIDE JACKET TO PROTECT EXPOSED <br /> INSULATED PIPING ON ROOF IN ACCORD WITH INSULATED PIPING ON ROOF IN ACCORD WITH PROVIDE DOUBLE SUCTION RISER <br /> SPECIFICATIONS SPECIFICATIONS FROM CEILING SPACE TO ABOVE ROOF <br /> PIPING FROM PIPE BOX, COORDINATE WITH PIPING FROM PIPE BOX, COORDINATE WITH / AS NOTED ON THE REFRIGERATION <br /> ROOFTOP ARCHITECTURAL DRAWINGS ROOFTOP ARCHITECTURAL DRAWINGS SCHEDULE WHEN RISERS ARE <br /> COMPRESSOR INVERTED P-TRAP AT COMPRESSORINVERTED P-TRAP AT GREATER THEN 6' IN HEIGHT. <br /> RACK AND TOP OF SUCTION RISERS INVERTED P-TRAP RACK AND TOP OF SUCTION RISERS STRUT <br /> CONDENSER REFRIGERANT PIPING AT TOP OF SUCTION CONDENSERINVERTED <br /> UNIT RISER UNIT REFRIGERANT PIPING ROOF PIPE BOX TRAPS MOUNTED <br /> SEAL PENETRATIONS AT SEAL PENETRATIONS ATILI CLAMP <br /> PIPE BOX AND ROOF DECK. ROOF PIPE BOX AND ROOF DECK. ROOF / <br /> HANGER, SEE DETAIL 4/R511 HANGER, SEE DETAIL 4/R511 11, i If <br /> / INVERTED P-TRAP / <br /> AT TOP OF SUCTION INVERTED RISER <br /> REFRIGERATION <br /> RISER CEILING AT TOP OF RISER PIPING <br /> SEAL =_ SEAL APPROVED PIPE <br /> PENETRATIONS 10 REFRIGERATION CEILING PENETRATIONS <br /> AT PIPE BOX � � I- 10" � REFRIGERATION ------- DUAL TEMP DOUBLE HANGER, SEE DETAILS <br /> No. <br /> RISERS Date o. Description <br /> PIPING RISERS AT PIPE BOX <br /> SUCTION RISER IN FALSE 4/R511 &5/R511. <br /> S COLUMN OR WALL. 01/17/2019 PERMIT ISSUE <br /> / REFRIGERANT PIPING / REFRIGERATION PIPING TO <br /> CEILING TO BE INSTALLED IN OR CEILING BE INSTALLED IN FALSE FOR SMALLER DIAMETER <br /> FALSE COLUMN. LCF <br /> ONTINUATION COLUMN. CONTINUATION SUCTION RISER. FOR <br /> TRAP AT SEE ARCHITECTURAL TRAP AT <br /> 7 1/2" SEE DETAIL 14/R511 SEE DETAIL 15/R511 SIZE SEE DAIRY INSULATION COUPLING OR <br /> BOTTOM 7 1/2" SUCTION RISER LINE SUCTION LINE <br /> BOTTOM FOR ENCLOSURE. 10" MAX INSULATED INSERT. REFER TO <br /> OF SUCTION OF SUCTION LARGER DIAMETER SUCTION RISER. SIZE COLUMN IN THE SPEC. SECTION 24 0719. <br /> RISERS RISERS TRAP AT BOTTOM FOR SIZE SEE ICE CREAM SUCTION RISER ROOFTOP COMPRESSOR <br /> CEILING OF SUCTION RISER LINE SIZE COLUMN IN THE ROOFTOP RACK AND CONDENSER LIQUID LINE <br /> COMPRESSOR RACK AND CONDENSER UNIT AND MARKET <br /> SLOPE REFRIGERATION CASES SLOPE REFRIGERATION CASES UNIT AND MARKET AREA REFRIGERATION AREA REFRIGERATION <br /> PIPING 1" IN 20'TOWARD TRAP AT BOTTOM PIPING 1" IN 20'TOWARD SCHEDULE ON SHEET R601. SCHEDULE ON SHEET R601. UNISTRUT MOUNTED TO <br /> ROOFTOP COMPRESSOR OF SUCTION RISER ROOFTOP COMPRESSOR ARCHITECTURAL STEEL <br /> RACK AND CONDENSER RACK AND CONDENSER SUCTION LINE FROM TOP STUD. <br /> UNIT. UNIT. OF DUAL TEMP CASE. <br /> CONTRACTOR TO INSTALL CONTRACTOR TO INSTALL — <br /> CASE MANUFACTURER CASE MANUFACTURER <br /> FURNISHED TRIM PIECE. FURNISHED TRIM PIECE. <br /> FINISHED FLOOR FINISHED FLOOR <br /> TRAP <br /> REFRIGERANT PIPING FOR SALES FLOOR REFRIGERANT PIPING FOR SALES FLOOR <br /> 6 CASES @ FALSE COLUMN _ 7 CASES @ WALL 8 DUAL TEMP DOUBLE SUCTION RISER DETAIL 9 TOP OF RISER DETAIL 10 RISER SUPPORT DETAIL 11 NOT USED - <br /> R511 NOT TO SCALE R511 NOT TO SCALE R511 % NOT TO SCALE R511 NOT TO SCALE R511 NOT TO SCALE R511 <br /> SET SUCTION AND LIQUID PIPING <br /> ELECTRONIC EVAPORATOR PRESSURE ON TOP OF 1"THICK BY 4"WIDE SET SUCTION AND LIQUID PIPING - <br /> PIPING SHALL BE INSTALLED REGULATOR EEPR). INSTALL ON REFRIGERATION PIPING UP IN FALSE STRIP OF RIGID INSULATION CONNECT TO LIQUID AND SUCTION ON TOP OF 1"THICK BY 4"WIDE <br /> INSTALL CASE I COLUMN. SEE ARCHITECTURAL DRAWINGS SPACED EVERY 4'-0" <br /> CONTRACTOR TO REFRIGERATION PIPING BELOW TOP OF TRIM PIECE CASES WHERE INDICATED ON THE ON TOP OF PIPING CONNECTIONS AT THE TOP STRIP OF RIGID INSULATION <br /> ; OF THE CASE. TYPICAL. <br /> 7 1/2" HIDDEN FROM VIEW. REFRIGERATION SCHEDULES SEE R601. FOR FALSE COLUMN. COORDINATE PIPING SPACED EVERY 4'-0" ON TOP OF <br /> MANUFACTURER� � CASE. TYPICAL. INSTALL CASE MANUFACTURER <br /> FURNISHED TRIM CONTRACTOR TO INSULATED SUCTION LINE WITH PLUMBING PIPING AND ELECTRICAL FURNISHED TRIM PIECE ON SUCTION AND LIQUID HEADER CASE. TYPICAL. <br /> PIECE. INSTALL CASE LIQUID LINE INSTALL CASE MANUFACTURER CONDUITS ALSO LOCATED IN COLUMN. TOP OF CASE. PIPING ON TOP OF CASE. SEE DETAIL 13/R511. <br /> FAN BLOWER KIT TO VENTILATE MANUFACTURER FURNISHED TRIM PIECE ON TOP I <br /> SPACE BETWEEN BACK OF CASE FURNISHED TRIM 00 CONNECTED TO CASE OF CASE. <br /> AND WALL. PIECE. MANUFACTURER <br /> 7 1/2" SUPPLIED PIPING. <br /> INSTALL CASE CONTRACTOR TO INSTALL CASE —N <br /> MANUFACTURER MANUFACTURER FURNISHED FAN 7 1/2" SUCTION AND LIQUID HEADER <br /> / FURNISHED END TRIM PLATE BLOWER KITS AND BLANK-OFF PANELS. PIPING ON TOP OF CASE. i <br /> ON BOTH ENDS OF LINEUP. INSTALL IN ACCORD WITH CASE N FJ 71 <br /> CONNECT TO LIQUID AND SUCTION <br /> bJ MANUFACTURER'S INSTRUCTIONS. S S PIPING CONNECTIONS AT THE TOP <br /> FASTEN AND SEAL TO CASE AND WALL. L L9OF THE CASE. TYPICAL. <br /> \ � Fq INSTALL CASE MANUFACTURER <br /> SUCTION AND LIQUID INSIDE Cn D DAIRY CASE SEE DETAIL 13/R511. DAIRY CASE S (N) S (N) FURNISHED TRIM PIECE ON <br /> CASE BY CASE MANUFACTURER. m r U D UU L L <br /> \ 7 @ � -E EH AEE r/AB01B B01A TOP OF CASE. <br /> H1 ffi ER <br /> MINIMUM 4" SPACE BETWEEN SET SUCTION AND LIQUID HEADER DUAL TEMP CASE FROZEN CASE LINE UP (�(� UU UU <br /> WALL AND CASE. ON TOP OF 1"THICK BY 4"WIDE M / <br /> STRIP OF RIGID INSULATION �" LF] p L <br /> SPACED EVERY 4'-0" C S S <br /> GYP WALL \ C N <br /> LJ LJ <br /> WALL <br /> MINIMUM 4" SPACE BETWEEN WALL —rte FURNISHED FAN BLOWER KIT. QFLOFESS11 <br /> INSTALL CASE MANUFACTURER <br /> AND CASE. INSTALL CASE MANUFACTURER FASTEN AND SEAL FAN KIT TO CASE REFRIGERATION PIPING DOWN IN H. M/4� <br /> INSTALL CASE <br /> ELECTRONIC EVAPORATOR PRESSURE FURNISHED BLANK-OFF PANEL TO AND WALL. TYPICAL. FALSE COLUMN TO THE TOP OF CASE. � <br /> C., <br /> MANUFACTURER REGULATOR (EEPR). INSTALL ON SEAL THE TOP OF THE CASE. FASTEN cam, <br /> FURNISHED END KICK PLATE CASES WHERE INDICATED BY THE AND SEAL BLANK-OFF PANEL TO CASE ELECTRONIC EVAPORATOR 31885 <br /> EXTENSION. REFRIGERATION SCHEDULES ON R601. L L L L AND WALL. NOTCH BLANK-OFF PANEL PRESSURE REGULATOR (EEPR). P: 12/31/19 <br /> GYP WALL SEE DETAIL 13/R511. AS NEEDED TO ACCOMMODATE INSTALL ON CASES WHERE <br /> INSTALL CASE MANUFACTURER FURNISHED PIPING OR WIRING CONNECTIONS. INDICATED BY THE `rTy�FCNAMCP���P <br /> 30" LONG BLANK-OFF PANEL. CUT BLANK- USE 1/2" KO BUSHING AROUND REFRIGERATION FpF CAI�F� <br /> FINISHED FLOOR INSTALL CASE MANUFACTURER FURNISHED OFF TO FIT. FASTEN AND SEAL TO BOTH VACUUM HOSE PENETRATION. SCHEDULES ON R601. <br /> FAN BLOWER KIT. INSTALL PER CASE CASES. NOTCH BLANK-OFF PANELS AS TYPICAL. <br /> SEE DETAIL 13/R511. <br /> MANUFACTURERS INSTRUCTIONS. FASTEN NEEDED TO ACCOMMODATE PIPING OR <br /> 12 CASE FAN BLOWER DETAIL - CASE TO WALL 13 TOP OF SALES FLOOR CASES 14 CASE PIPING DETAIL AND SEAL FAN KIT TO BOTH CASES. TYPICAL. WIRING CONNECTIONS. TYPICAL. 15 CASE PIPING DETAIL <br /> R511 NOT TO SCALE R511 NOT TO SCALE R511 NOT TO SCALE R511 NOT TO SCALE <br /> DATE: 01/17/2019 <br /> -------------,— THREADED ROD TO <br /> STRUCTURE ABOVE. <br /> SUCTION LINE RETURN 3" LOOP <br /> - THREADED ROD. <br /> LIQUID LINE RETURN <br /> INCREASE THE LIQUID LINE TWO SIZES <br /> FROZEN CASE SYSTEM LINE-UP OVER THE LINE SIZE (5/8"TO 7/8") FOR <br /> WITH HOT GAS DEFROST IN CASE LIQUID HEADER. TAKE OFFS <br /> CONNECT MAIN LIQUID AND SUCTION LINES <br /> FOR EVAPORATORS EXIT THE BOTTOM <br /> FOR SYSTEM LINE-UP TO LIQUID AND SUCTION � <br /> OF THE LIQUID HEADER. PROVIDE 3" CONNECTION POINTS FURNISHED AT THE TOP <br /> EXPANSION LOOP AT CONNECTION TO OF THE CASE. ONLY ONE CASE IN THE SYSTEM <br /> El El F1 7 F1 F1 El LIQUID HEADER. LINE-UP WILL BE FURNISHED WITH TOP <br /> Q CONNECTIONS. 0 <br /> EVAPORATOR EVAPORATOR T� 14"X14" UNISTRUT <br /> _ <br /> TXV VALVE TYP. PIPE SUPPORT, IF RISER O� LIQUID AND SUCTION PIPING � � � i � � ' � % <br /> / FROM TOP OF CASE TO INSIDE IS OVER 6-0" PROVIDE <br /> L L <br /> ADDITIONAL UNISTRUT. Lo <br /> O Lo <br /> LOWER FRONT OF CASE <br /> S S 1 FURNISHED BY CASE <br /> MANUFACTURER. � T <br /> CONNECT TO CASE MANUFACTURER PIPE SUPPORT >. <br /> W <br /> FURNISHED PIPING INSIDE CASE. <br /> SEE DETAL10/R511 J <br /> SUCTION LINE MAY BE i i i i i i � <br /> REDUCED ONE PIPE SIZE PIPE INSULATION Q <br /> PROVIDE LIQUID AND SUCTION HEADER AFTER 1/3 OF THE LOAD Q ( 1 <br /> INSIDE LOWER FRONT PART OF CASE AND AND REDUCED AGAIN <br /> CONNECT TO EVAPORATOR COILS. INSTALL AFTER 2/3 OF THE LOAD. <br /> ACCORDING TO CASE MANUFACTURER'S THE SUCTION HEADER C <br /> INSTALLATION INSTRUCTIONS. SHOULD NOT BE REDUCED 0 <br /> BELOW THE COIL REFRIGERATION PIPES 00 <br /> CONNECTION SIZE. <br /> N <br /> 16 NOT USED 17 PIPING DETAIL FOR FROZEN CASE LINEUP W/HOT GAS DEFROST 18 FALSE COLUMN PIPE SUPPORT 19 NOT USED 20 NOT USED <br /> R511 R511 NOT TO SCALE R511 NOT TO SCALE R511 R511 <br /> LIQUID LINE <br /> HAND VALVE <br /> (SUPPLIED BY�� <br /> REFRIG CONT.) <br /> LIQUID LINE <br /> SOLENOID VALVE <br /> (SUPPLIED BY <br /> RTCR MFG.) <br /> SERVICE VALVE <br /> (SUPPLIED BY <br /> REFRIG CONT.) Project Number T-0738 <br /> CASE Config: LL <br /> Drawn By K. Snyder <br /> SERVICE VALVEy M. Perrodin <br /> (SUPPLIED BY Checked B <br /> REFRIG CONT.) <br /> ELECTRONIC EVAPORATOR REFRIGERATION <br /> PRESSURE REGULATOR <br /> (SUPPLIED BY RTCR MFG.) DETAILS <br /> T�HAND VALVE <br /> (SUPPLIED BY <br /> 21 NOT USED 22 NOT USED 23 NOT USED SUCTION LINE REFRIG CONT.) <br /> R511 R511 R511 <br /> ALL WORK ON REFRIGERATION DRAWINGS SHALL BE COMPLETED BY TARGET APPROVED REFRIGERATION CONTRACTOR UNLESS NOTED OTHERWISE. 24 LOOP PIPING SCHEMATIC 5 1 <br /> R511 NOT TO SCALE <br /> 1/17/2019 10:02:20 AM <br />