My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 Refrigeration Freezer Schedule GENERAL NOTES <br /> SYST# Equipment ID REFRIGERATION CASES Lighting Apparent Lighting Panel Lighting CCT Fans&AS Fans and AS Fans and AS CCT NOTES A. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. <br /> MODEL USE Power Number Apparent Power Panel Number <br /> ID5NM BA01 5'OPEN CASE REFRIG 96 VA LP-12B 23 624 VA LP-12B 34 B. UNDER SLAB CONDUIT SHALL BE 3/4"MINIMUM, UNO. <br /> ID5NM BA02 S OPEN CASE REFRIG 96 VA LP-12B 23 624 VA LP-12A 29 <br /> RMN B07 3 DOORS REFRIG 96 VA LP-12B 21 480 VA LP-12B 30 C. INSTALL OWNER FURNISHED POWER POLE(OFME E1)AND <br /> 5' 6 7/8" 5' 01/4" 5' 01/2" 5' 01/2" 5' 0 1/2" 2' 8 3/8" MANUFACTURED WIRING SYSTEM CABLE FROM J BOX TO POWER TARGET® <br /> REFRIGERATION NOTES: POLES. <br /> J ALL NEW CIRCUITS FOR REFRIGERATION ARE 120V, 1 PHASE,2#10,#10 GROUND D. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY.REFER TO <br /> "U[51i3LO"" 51 86 51 30"(b 51 30� 51 MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. 1000 NICOLLET MALL <br /> LP 1/11LP11 LP2/40 MINNEAPOLIS, MN 55403 <br /> I� 5 E. REFER TO SHEET E521 FOR FLOOR BOX DETAILS.L L F REVISE EXISTING FIRE ALARM DEVICE LOCATIONS IN THIS F. REFER TO 6/E531,7/E531 AND 8/E531 FOR TYPICAL POWER POLE <br /> LP-1 L ROOM THAT ARE LOCATED ON EXISTING WALLS OR CEILINGS352 THAT ARE REMOVED/REVISED. RELOCATE DEVICE TO NEARESTINSTALLATION. <br /> LRESHOP FIRE ALARM CABINETS EXISTING/NEW WALL OR EXISTING/NEW CEILING THAT WILL�;, % i MEET ALL APPLICABLE REQUIREMENTS OF NFPA 72 AND THE G. REFER TO DETAILS 9,10,11,12,13,16, 17,18&19/E511 FOR CONDUIT <br /> 105A SUPPORTS AT ROOF STRUCTURE.REFER ALSO TO <br /> AUTHORITY HAVING JURISDICTION.NEW DEVICES MAYBE SPECIFICATIONS. <br /> REMS-1 REQUIRED IF EXISTING DEVICES ARE NOT SUITABLE FOR <br /> RELOCATION. H. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER <br /> LP-2/40 LP-2/40 VOLTAGE SERVICE <br /> FITTING MONITOR K CIRCUIT. <br /> ROOM TX 7 ROOM MDS-SERVICE MDS T-1 LP 2 LP-13 DC ENGINEERING <br /> 311 OO USB I EMS 138A I ENTRANCE I. REFER TO SPECIFICATIONS LOW VOLTAGE CABLE SUPPORT <br /> L LOCATION. Careful listening. Dynamic solutions. <br /> LP-2/40 MDS-SERVICE DS-SERVIC T14 MARKET CONDUCTOR SPLICING <br /> CONT ENTRANCE ENTRANCE J. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING www.dcengineering.net <br /> l CAB ELECTRICAL ALTERNATE SYSTEM.REFER TO PRE MANUFACTURERS INSTALLATION Phone:208.288.2181 Project:1 8TAR1 7 <br /> ELECTRICAL #2 ENG GEN DRAWINGS FOR INSTALLATION REQUIREMENTS. <br /> 138 <br /> ✓/ \ FITTING 154 CONT INCLUDE ALL MARKET HOMERUNS IN ORIGINAL BID PER POWER K. EXISTING JUNCTION BOXES,CIRCUIT NUMBERS AND HOMERUNS <br /> ROOM HL-3 SYSTEM PLANS AND EQUIPMENT SCHEDULES.EXISTING SHOWN ARE FOR REFERENCE ONLY AND WERE TAKEN FROM <br /> r� USB LOUNGE LP LP-7 CAB CONDUCTORS IN MARKET AREA CAN BE SPLICED AND EXTENDED TO EXISTING PLANS. VERIFY EXACT CONDITIONS AT SITE. <br /> H4 -214 - 1 - 2 - � - <br /> 352 810 <br /> #3 <br /> / 5 5 /8 8 5 5/8 3 LP 2/40 <br /> � 40 NEW EQUIPMENT LOCATION WHEN EXISTING WIRING CONFIGURATION <br /> 1056 F <br /> �❑ F7 MATCHES NEW EQUIPMENT LOADS AND WIRING REQUIREMENT L. ELECTRICAL CONTRACTOR TO PROVIDE J-BOX FOR TEMP <br /> T 5 TE-1 LPE 1 CONT CONT SHOWN ON POWER&SYSTEM PLANS AND EQUIPMENT SCHEDULES. SENSORS IN FINISHED WALLS. REFER TO THE MECHANICAL <br /> 30" LP 1/11 30" LP-1/11 3051 LP-1/11Q� PLANS FOR RTU AND VAV TEMP SENSOR LOCATIONS. <br /> ❑ 1� <br /> T-2 T-4 ATS-1 <br /> AT 2 LP 1 T 13 T 3 LP 4 HLE 1 #1A LCP HL 1 #1 HL-2 VERIFY ON SITE IF EXISTING CONDUCTORS IN MARKET ARE CAN BE <br /> 51 51 336 ®OL SPLICED AND EXTENDED.WHEN EXISTING CONDUCTORS CAN BE <br /> TE-1, TE-1, TE-1, HP-1 Sec.2 HP-1 Sec. 1 REUSED PROVIDE DETAILED ALTERNATE DEDUCTION AND REQUEST KEYNOTES <br /> 147 45A 45A 45A APPROVAL TO PROCEED FROM TARGET CPM. <br /> DS DS DS # DESCRIPTION <br /> FITTING ROOM POWER & SYSTEMS PLAN 3 FRONT ELECTRICAL ROOM 154 4 REAR ELECTRICAL ROOM 138 REFER TO SPECIFICATION FOR SPLICING REQUIREMENTS. <br /> 2 51 PROVIDE SINGLE RECESSED RECEPTACLE CLOCK BOX OUTLET <br /> E211 SCALE: 1/4" = V-0" E211 SCALE: 1/4"= V-0" E211 SCALE: 1/4"= V-0" WHEN SPLICING IS POSSIBLE USE THE GENERAL CIRCUIT AT 30"AFF. CENTER OUTLET ON MIRROR. VERIFY FINAL <br /> INFORMATION BELOW: LOCATION OF FITTING ROOM MIRROR LIGHT(MR1)WITH FINAL <br /> FIXTURE PLAN. MIRROR LIGHTS ALSO TO BE CONNECTED TO <br /> CIRCUIT NUMBERS IN THE REFRIGERATION SCHEDULE AND THE FITTING ROOM PENDANT LIGHTING CIRCUIT. <br /> PANELBOARD SCHEDULE ARE BASED OFF ASBUILT DRAWINGS.THE 105 RECESSED MOUNTED LINEAR LED LIGHT. CONNECT <br /> EXACT CIRCUIT THAT IS AVAILABLE TO SPLICE MAY NOT MATCH WHAT NON-EMERGENCY LINEAR LED LIGHT FIXTURES TO EXISTING 2X4 <br /> THE 3 4 5 7 9 10 11 UNLESSA SPNGS INDICATE UTILIZE THE NEAREST ECIFICALLY FICALLY CALLE OUT ASN W TO FEED IATBLE CIRCUITS SALES HE CASE.THE DEMOLISHED. LIGHT FIXTURE CIRCUITS THAT WERE <br /> �- - CIRCUITS USED MUST FOLLOW THE SAME GENERAL INTENTION SO <br /> I I 129 PROVIDE J-BOX AT TOP LATCH SIDE OF SIDE OF COMPACTOR <br /> CIRCUITS ARE NOT OVERLOADED OR SHARED OVER MULTIPLE DOOR AND STUB 3/4"CONDUIT UP TO JOIST SPACE. <br /> I I REFRIGERATION SYSTEM(S)UNLESS SPECIFICALLY INDICATED TO BE 130 PROVIDE SWITCH ADJACENT TO EXHAUST FAN FOR SERVICE Date NO. Description <br /> SHARED IN THE REFRIGERATION SCHEDULE. REFER TO THE DISCONNECTING MEANS. <br /> ° I 5 4 REFRIGERATION SCHEDULE FOR INTENT. 131 PROVIDE POWER CONNECTION TO DOOR CLOSER. 01/17/2019 PERMIT SET <br /> ° I E211 E211 3/4"C 2#10,1#10G 132 EXISTING FIRE ALARM AND INTRUSION DEVICES FOR <br /> CASE FAN CIRCUITS CAN NOT BE SHARED OVER MULTIPLE <br /> 476 REFRIGERATION SYSTEM(S).THEY CAN BE SHARED OVER MULTIPLE COMPACTOR TO REMAIN/RE-INSTALLED SIMILAR TO EXISTING <br /> 154 AT ROOF I D LP-2 CASES WITHIN THE SAME REFRIGERATION SYSTEM.CASE DOOR HEAT UNLESS NOTED OTHERWISE ON THESE DOCUMENTS. <br /> J • �— — CIRCUITS CAN NOT BE SHARED OVER MULTIPLE REFRIGERATION 144 ROUTE CONDUIT DOWN THE MIDDLE OF THE BACK TO BACK <br /> K I W J - PD 19 K SYSTEM(S).THEY CAN BE SHARED OVER MULTIPLE CASES WITHIN HEAVY DUTY RACKING. <br /> J I ❑ THE SAME REFRIGERATION SYSTEM. 147 VERIFY LOCATION OF PUBLIC VIEW MONITOR WITH VOICE/DATA <br /> LOW VOLTAGE CONTRACTOR.STUB 3/4"FLEX CONDUIT OUT OF <br /> T T B L IGN CIRCUITS FEEDING CASE LIGHTING AND LOW TEMP DOOR HEAT MUST WALL ABOVE PUBLIC VIEW MONITOR AT 8'-4"AFF FOR ROUTING <br /> �� m BE ROUTED THROUGH EITHER THE REFRIGERATION EMS PANEL OR A OF PUBLIC VIEW CABLES.CUT CONDUIT FLUSH WITH WALL <br /> 0 CONTACTOR. REFER TO THE CONTACTOR SCHEDULE LOCATED ON SURFACE AND PROVIDE BUSHING. <br /> SHEET E601. 148 INTERCEPT AND EXTEND NEAREST NORMAL POWER 120V <br /> ° ° - CIRCUIT TO NEW RECEPTACLE. <br /> 10G — — MIE \ 150 PROVIDE CONNECTION FROM EXISTING BALER DISCONNECT <br /> ❑ LV❑ �V❑ m SWITCH TO NEW BALER CONTROLS. BALER CONTROLS <br /> 108" FURNISHED BY BALER VENDOR. <br /> 2 1 153 PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING LINE OR <br /> ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN UNFINISHED <br /> 791 33 160 E381 E381 AREAS FOR PARAPET MOUNTED CCTV CAMERA. PROVIDE 1" <br /> CCN 159 338 144 161 - CONDUIT TO JUNCTION BOX MOUNTED ON PARAPET. REFER TO <br /> 60" <br /> 48- • V DETAIL 9/E521. <br /> WP 154 PROVIDE WEATHERPROOF JUNCTION BOX AND 1"LIQUIDTIGHT <br /> ° ° . ° <br /> - - - — - -- - - - - -_ - - _ <br /> J — — LP-1/2 4 FLEXIBLE CONDUIT AND FITTINGS TO PARAPET MOUNTED CCTV <br /> CAMERA. <br /> ❑ ❑ ❑ ❑ 159 PS_ PS -PS 159 PROVIDE 6'OF 3/4"FLEX CONDUIT TO CAMERA.VERIFY FINAL <br /> 15 LP-1/2 , LP-1/20, <br /> 14 338 144]33A LP-1 J LOCATION WITH LOW VOLTAGE CONTRACTOR. <br /> 2 R R R I 352 20 2 LP-1/10 LP-1/10 LP-1/14 LP-1/14 160 PROVIDE JUNCTION BOX AT T-6"AFF FOR CCTV CAMERA. MOUNT <br /> E211 ❑ I -o JUNCTION BOX ON END OF BULK RACKING.COORDINATE <br /> LP-1/12 LOCATION WITH CCTV VENDOR. <br /> ❑ H I ❑ I I 459 161 PROVIDE JUNCTION BOX ABOVE CONVEYOR.MOUNT JUNCTION <br /> BOX AT T-0"AFF ON BULK RACKING.COORDINATE LOCATION <br /> I I H WITH CCTV VENDOR. <br /> PEA 182 I� �� I 1g2 I I LP-1/12 181 COLUMN MOUNTED CONVENIENCE RECEPTACLE. REFER TO <br /> DETAIL 8/E511.PROVIDE CONNECTION TO EXISTING <br /> „ ILP 8/17 ° CONVENIENCE RECEPTACLE CIRCUIT IN THE AREA. <br /> LD 182 EXISTING COLUMN MOUNTED RECEPTACLE.CONTRACTOR TO <br /> — — — — — — — — — — LP 8 352810 <br /> VERIFY EXISTING RECEPTACLE EXISTS IN THIS LOCATION L <br /> 352 810 NEARBY. IF EXISTING RECEPTACLE DOES NOT EXIST INSTALL <br /> ❑ E531 TYP. 216 472 17 NEW AND PROVIDE CONNECTION TO NEAREST EXISTING <br /> (macx (macx) LP 1 352 CONVENIENCE RECEPTACLE IN THE AREA. REFER TO DETAIL <br /> Ell 8/E511. <br /> ❑ O O L3-1/ LP 1/7 LPT -1/9 LP 1/9 2,4,10,12,14 190 PROVIDE JUNCTION BOX MOUNTED ABOVE ACCESSIBLE CEILING <br /> 616 R R WITH 120V POWER FOR FUTURE.LOCATE JUNCTION BOX AS <br /> -LP-1/3 LP 1/3 LP 1/ 468 LP 1!5 LP 1/7 LP 1/7 46 468 46 F,-[WLP 1/9 INDICATED ON DRAWINGS.JUNCTION BOX TO COME WITH 9' <br /> G 465 LP-1/1 46 PREMANUFACTURED RELOC WHIP WITH CONNECTOR COIL WHIP <br /> C ABOVE CEILING FOR FUTURE USE. <br /> 16" <br /> 216 ELECTRICAL CONTRACTOR TO INSTALL OWNER FURNISHED EMS <br /> ❑ 182 :: JLP-1/1 LP-1/3 LP 1 182 LP 1 TARGET BULLSEYE SIGN CABLING FROM THE EXISTING REMS PANEL NOTED TO THE PET <br /> 3/4"C-2#10,1#10G <br /> (macx) 182 3,5 352 7 9 352 LP 2 COOLER LOCATION AND MAKE FINAL TERMINATIONS AS <br /> _171REQUIRED. <br /> ❑ ❑ El- 21 303 PROVIDE J-BOX FOR FIRE ALARM SYSTEM HEAT DETECTOR <br /> LP 1 o CENTERED ABOVE COMPACTOR DOOR,APPROXIMATELY 2'-0" <br /> 1 J 3/4"C-2#10_FT7FMT=T=L4 ,1#10G FROM WALL ON BOTTOM OF TOP CHORD OF ROOF SUPPORT Qp,OF / <br /> ( acx) MEMBER. PROVIDE RACEWAY BETWEEN FIRE ALARM SYSTEM Gp,� <br /> ❑ 190 AND DOOR RELEASE.LL <br /> 376 377 311 PROVIDE RECEPTACLE FOR LED HALO MIRROR. INSTALL w Z m <br /> RECEPTACLE AT 24" <br /> NNECT TO <br /> F1 476 CIRCUIT THAT FEEDS FITTING ROOM PENDANTS. <br /> 120V SWITCHED BRANCH * 18 3 <br /> 336 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. <br /> .. a � 399 �,__ � I F�FCTR�OP���P <br /> F u .� I-- ISI A P-1/1 182 y �RMN F 338 STUB CONDUIT(3/4"OR AS NOTED) FROM J BOX TO AREA ABOVE 9P�c OF CA��Fp� <br /> 182 �� 182 B07 CEILING LINE OR ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN <br /> UNFINISHED AREAS. <br /> 565 ❑ r_ 352 EXISTING HOMERUN LOCATED ABOVE CEILING/IN JOIST SPACE <br /> r ❑1 _28 EM SHOWN FOR REFERENCE. PROVIDE CONNECTION TO <br /> LP-2/�7 I <br /> acx) (macx) NEW/RELOCATED DEVICE/LIGHT FIXTURE. <br /> ❑ 375 INSTALL OWNER FURNISHED MARKET LIGHTING CONTROL PANEL 1/17/2019 <br /> e e (macx) (ML-CP-1)PROVIDE 120V POWER AS INDICATED. EMS <br /> Li <br /> ❑ � � � � � LP-6/2 LP-6/2 � I CONNECTIONS PROVIDED BY TARGETS EMS VENDOR. <br /> II 376 PROVIDE J BOX AT 86"AFF. PROVIDE 1"C FROM J BOX TO <br /> V STUB OUT AT 2"AFF. PROVIDE FLEXIBLE CONDUIT FROM STUB TO <br /> (bx1 bx1) CASE WIREWAY.PROVIDE FINAL CASE CONNECTIONS FOR <br /> - 182 POWER WIRING. O <br /> r LP 2/7 181 FIAC 377 PROVIDE 1"C(OR AS NOTED ON PLANS),HOMERUN FOR POWER <br /> E I `� H C WIRING.CONCEAL IN WALL TO ABOVE THE CEILING. REFER TO u, <br /> -'' <br /> LP-2/7 182 THE REFRIGERATION EQUIPMENT SCHEDULE FOR CIRCUIT <br /> LI I182 � � � @�� 182 LP-6/2 LP-6/2 REQUIREMENTS FOR EACH CASE. <br /> 399 PROVIDE(2) 1"C FOR LV CABLE.PROVIDE CONDUIT FROM Q <br /> 000 <br /> 465 ACCESSIBLE CEILING SPACE TO STUBOUT AT 88". INSTALL <br /> TYP CABLES TO TOP OF CASES. REFER TO SHEET R621 FOR REMS Z <br /> CABLES AND ROUTING. <br /> TARGET BULLSEYE SIGN h1 �I �I 459 RELOCATED SEASONAL POWER POLE. EXTEND EXISTING <br /> CIRCUIT TO NEW LOCATION. O <br /> 465 PROVIDE RECEPTACLE IN GONDOLA BASE DECK.ROUTE CORD <br /> rp El � HH- ( FROM DISPLAY TO RECEPTACLE.REFER TO 4/E531. L.L <br /> LP-8 468 RELOCATED TOYS POWER POLE. PROVIDE CONNECTION TO /� J <br /> SLP-8/23 23 352 810 -- 182 EXISTING TOY CIRCUITING AS INDICATED. \` <br /> D - - `� LP 6 - - D 472 MOUNT RECEPTACLE FOR FRESH PET SELF CONTAINED CASE TO a <br /> 352 e 182 182 FIXTURE RAIL IN BASE DECK OF FIXTURE SIMILAR TO 4/E531 . U 1 <br /> 476 182E!!M I " 4 2 ° 476 PROVIDE 3/4"IMC THRU EXTERIOR WALL FOR POWER �•J <br /> O 1 506 <br /> BA <br /> CONNECTION TO EACH SIGN LETTER.COORDINATE EXACT .. <br /> E385 LOCATION OF PENETRATION AND SIGN REQUIREMENTS WITH <br /> ID5NM J SIGN VENDOR AND GC. REFER TO 5/E521. (� <br /> —[� — — — — — — — — — — — — — — — — — — — — — — — — — — — — 506 PROVIDE 120V CONNECTIONS TO NEW REFRIGERATED OPEN v <br /> e fV O max CASE. UTILIZE EXISTING CIRCUITS RETAINED FROM DEMO OF 2 <br /> ® O � � I � � � DOOR CASE. DO NOT RECONNECT DOOR HEAT CIRCUIT.REFER n/ <br /> TO REFRIGERATION SCHEDULE FOR CIRCUITING INFORMATION. <br /> ID5NM J ll J 565 PROVIDE RECEPTACLE FLUSH IN KICK PLATE OF GONDOLA, <br /> BA01 BG-1 PROVIDE STAINLESS STEEL COVERPLATE. <br /> o ®DD° �, I O I 616 INSTALL RECEPTACLE HORIZONTALLY IN FREE STANDING <br /> � o I I COMPACTOR CHUTE INSTALL CONTROL FURNISHED <br /> 182 EXHUST FAN WITH COMPACTOR. GONDOLA. <br /> Dc <br /> I ❑ �� I I o 506 338 129 132 791 RECEIVING DOOR IS ELECTRICAL CONTRACTOR TO IPRIOR TO NEW WORK <br /> FY EXISTING LL AT L.L <br /> 303 PERFORMED AND AGAIN AFTER THE REMODEL IS COMPLETE. W <br /> r I I 130 ` L WORK WITH STORES PMT TO PERFORM THE COMMISSIONING OF W <br /> n �_ � I I LP-12A S EXISTING DOORBELL. DURING GENERAL DEMO WORK THE <br /> © I 18 / ELECTRICAL CONTRACTOR SHOULD VERIFY THAT THE BUZZER J <br /> CONT 375 _ F J 131 ISNOTREMOVEDER LOCATED ON THE INTERIOR OF THE STORE V <br /> CAB I _ F 810 UNKNOWN OR UNSURE CIRCUIT.CONTRACTOR SHALL FIELD <br /> u 7 <br /> 0 � � i � � ML-CP-1 z VERIFY CIRCUIT NUMBER AND LOCATION AND RECORD ON L <br /> ❑® REMS-L/DH rLP-12A V BUILDING AS-BUILT DRAWINGS, PANEL SCHEDULES AND <br /> LF-0 L LF-ED❑ ILI- I I CPANELOL LP 126 150 HL 2 352 DIRECTORIES. Q <br /> ° ® T 12 COMPACTOR/ 37,39,41 Q <br /> ® II HL-4 ® ® BALER 00 <br /> � II � 130 N <br /> v I O <br /> "38,4 ,42 <br /> 150 Project Number <br /> T-0738 <br /> vi <br /> A i I 2 3 'A BG-2 Config: LL <br /> E321 <br /> 1 E321 E2 <br /> Drawn By G.F I KRAT <br /> � � - - - <br /> - - - - - - - - - - - - - - - - - <br /> Checked By B.H U NT <br /> II II <br /> 17-7 1 <br /> E311 <br /> 7I POWER AND <br /> 1 2 3 4 5 6 7 8 9 10 11 SYSTEMS PLANS <br /> � I <br /> 1 POWER & SYSTEMS PLAN 5 COMPACTOR POWER & SYSTEM PLAN <br /> E211 SCALE: 1/16"= V-0" <br /> E211 SCALE: _ -0 <br /> 211 <br /> PLAN NORTH <br /> 1/17/2019 11:41:30 AM <br />