My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2800
>
1600 - Food Program
>
PR0505838
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2022 4:44:04 PM
Creation date
2/27/2019 11:40:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0505838
PE
1619
FACILITY_ID
FA0007036
FACILITY_NAME
TARGET T0738
STREET_NUMBER
2800
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
212-050-230-000
CURRENT_STATUS
01
SITE_LOCATION
2800 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEMOLITION KEYNOTES GENERAL NOTES <br /> ❑A EXISTING ELECTRICAL DEVICES IN THIS AREA TO BE REMOVED A. UNDER SLAB CONDUIT SHALL BE 3/4"MINIMUM. <br /> UNLESS NOTED OTHERWISE.MAINTAIN CIRCUITS ABOVE <br /> CEILING FOR RE-USE. PROVIDE NEW DEVICES AS INDICATED. B. REFER TO CHECKLANE DETAILS 15&16/E531. <br /> ANY DEVICES SHOWN AS GREY TONE ARE EXISTING TO REMAIN, <br /> ALL OTHERS TO BE REMOVED. C. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER <br /> CIRCUIT. TARGET® <br /> ❑B EXISTING ELECTRICAL DEVICES IN THIS AREA TO REMAIN. <br /> D. MOUNT JUNCTION BOXES ON STRUCTURE ABOVE CEILING. <br /> 167 DEVICES SHOWN AS GREY TONE ARE EXISTING TO REMAIN. <br /> EXTEND EXISTING CIRCUIT TO NEW DEVICES AS INDICATED. E. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY.REFER TO 1000 N I COLLET MALL <br /> OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. MINNEAPOLIS, MN 55403 <br /> F. ELECTRICAL CONTRACTOR TO PROVIDE J-BOX FOR TEMP <br /> EXISTING FIRE ALARM DEVICES SENSORS IN FINISHED WALLS. REFER TO THE MECHANICAL <br /> PLANS FOR RTU AND VAV TEMP SENSOR LOCATIONS. <br /> REVISE EXISTING FIRE ALARM DEVICE LOCATIONS IN THIS KEYNOTES <br /> ROOM THAT ARE LOCATED ON EXISTING WALLS OR CEILINGS <br /> THAT ARE REMOVED/REVISED.RELOCATE DEVICE TO NEAREST # DESCRIPTION <br /> EXISTING/NEW WALL OR EXISTING/NEW CEILING THAT WILL 155 PROVIDE CONDUIT PATHWAY FOR EXTERIOR WALL MOUNTED <br /> MEET ALL APPLICABLE REQUIREMENTS OF NFPA 72 AND THE CCTV CAMERA. PROVIDE JUNCTION BOX ABOVE ACCESSIBLE <br /> AUTHORITY HAVING JURISDICTION. NEW DEVICES MAYBE CEILING. PROVIDE 3/4"CONDUIT FROM JUNCTION BOX TO <br /> REQUIRED IF EXISTING DEVICES ARE NOT SUITABLE FOR EXTERIOR WALL MOUNTED CCN CAMERA.STUB CONDUIT THRU DC ENGINEERING <br /> RELOCATION. EXTERIOR WALL AND CUT CONDUIT FLUSH WITH FINISHED WALL <br /> SURFACE.VERIFY EXTERIOR CCN CAMERA LOCATION WITH Careful listening. Dynamic solutions. <br /> VOICEMATA LOW VOLTAGE CONTRACTOR. WWW.dcengineering.net <br /> 156 PROVIDE WEATHERPROOF JUNCTION BOX FOR CCTV CAMERA. Phone:208.288.2181 Project:1 8TAR1 7 <br /> MOUNT JUNCTION BOX TO BOTTOM SIDE OF STORE ENTRY <br /> CANOPY. PROVIDE 6'-0"WEATHERPROOF FLEXIBLE WHIP FROM <br /> JUNCTION BOX TO CCN HOUSING.STUB 3/4"CONDUIT FROM <br /> JUNCTION BOX TO AREA ABOVE ACCESSIBLE CEILING OF SALES <br /> FLOOR.FOR LOCATION OF CANOPY MOUNTED CCTV CAMERA. <br /> REFER ALSO TO LOW VOLTAGE VENDOR DRAWINGS <br /> 164 MOUNT RECEPTACLE AND DATA J-BOX FLUSH IN PEG BOARD AT 12" <br /> AFF. PROVIDE SHALLOW 1900 BOXES WITH 2-GANG 1/4"MUDRING <br /> AND CENTER BOXES WITHIN GONDOLA.DRILL 2-3/8"HOLE IN TOE <br /> KICK OF GONDOLA AND PLACE 2"SNAP-IN BUSHING TO PROTECT <br /> CORDS AND CABLES. <br /> 168 INSTALL OUTLET IN BACK WALL OF GONDOLA. ROUTE FLEX <br /> 2 CONDUIT FROM NEW DUCT INSERT/POWER POLE TO RECEPTACLE. <br /> 174 RELOCATED SELF CHECKOUT POWER POLE. PROVIDE METAL <br /> - FLEXIBLE CONDUIT WITH#10 WIRE TO SELF CHECKOUT <br /> RECEPTACLE AND ROUTE VIA POWER POLE TO JUNCTION BOX <br /> LOCATED ABOVE CEILING. PROVIDE GROUND WIRE IN FLEX <br /> CONDUIT. <br /> 176 INSTALL RECEPTACLE FOR COOLER FLUSH IN PEGBOARD AT 12" <br /> AFF.CONTRACTOR SHALL PROVIDE 1900 BOX WITH 2-GANG 1/4" <br /> MUDRING. DRILL 2-3/8"HOLE IN TOE KICK OF GONDOLA AND PLACE <br /> 2"SNAP-IN BUSHING TO PROTECT CORD. <br /> 177 INSTALL OWNER FURNISHED CHECKLANE POWER POLE PER <br /> \/ MANUFACTURES INSTALLATION INSTRUCTIONS. PROVIDE <br /> V CONNECTION TO EXISTING CHECKLANE POWER AND SYSTEMS AS <br /> REQUIRED. <br /> 179 INSTALL OUTLET IN BASEDECK OF GONDOLA SIMILAR TO 4/E531. Date No. Description <br /> 168 ROUTE FLEX CONDUIT FROM POWER POLE TO RECEPTACLE. 01/17/2019 PERMIT SET <br /> CONNECT TO NEARBY COOLER RECEPTACLE CIRCUIT. <br /> LP-9/23 164 LP-9/20 231 STUB 3/4"CONDUIT FROM J-BOX TO AREA ABOVE CEILING LINE. <br /> I 232 PROVIDE PULL BOX 24"ABOVE CEILING FOR EAS SYSTEM MODULE. <br /> LPE 1/ 179 PROVIDE QUAD RECEPTACLE AND DATA JACK INSIDE PULL BOX. <br /> 232 810 REFER TO 5/E511. <br /> 234 RE-USE EXISTING EAS POWER SOURCE RETAINED FROM <br /> LPE-1/10 <br /> I - DEMOLITION OF OLD. <br /> LPE-1/10 y 314 RELOCATED FIRE, INTRUSION, REMOTE ANNUNCIATOR PANEL, <br /> MANUAL PULL STATION&REMOTE ALARM REFRIGERATION PANEL <br /> 234 J 174 ALONG WITH ASSOCIATED HARDWARE(BACK BOXES,MUD RING, <br /> I ETC.)AT NEW GUEST SERVICE. EXTEND EXISTING CIRCUITING AND <br /> CONDUIT TO NEW GUEST SERVICE EQUIPMENT LOCATION. <br /> 8:1DEVICES TO BE SAFELY STORED AND PROTECTED DURING <br /> U I ( 1 � I��J � "PE-1 177 177 177 177 CONSTRUCTION UNTIL THEY ARE RE-INSTALLED. FIELD VERIFY ALL <br /> J 177 EXISTING LOW VOLTAGE DEVICES TO RELOCATE. <br /> LPE 1/7 336 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. <br /> ❑ O O o I LPE-1/ 352 SHOWN FOR REFERENCE.PROVIDEXISTING HOMERUN LOCATED E CONNECTIVE /ON TO JOISTIN SPACE <br /> NEW/RELOCATED DEVICE/LIGHT FIXTURE. <br /> 355 EXISTING RECEPTACLE TO BE REPLACED WITH NEW GFCI <br /> I LP"9L RECEPTACLE.MOUNT RECEPTACLE AT SAME HEIGHT AS EXISTING. <br /> 23 352 CONNECT TO EXISTING CIRCUIT. <br /> C 367 SAW CUT FLOOR AS REQUIRED AND PROVIDE WIRE AND CONDUIT <br /> ® ® � L C <br /> FOR RECEPTACLES,CONDUIT SIZE SHOWN ON FLOOR PLAN. <br /> til <br /> INSTALL CONDUIT FROM FLOOR BOX TO JUNCTION BOX ABOVE <br /> I �I 176 ACCESSIBLE CEILING. <br /> ❑ `1 J 368 SAW CUT FLOOR AS REQUIRED AND PROVIDE CONDUIT FOR LOW <br /> / ( ( LP 9/23 LP 9/26 VOLTAGE CABLING,CONDUIT SIZE SHOWN ON FLOOR PLANS. <br /> I LP-9/23 INSTALL CONDUIT FROM FLOOR BOX TO JUNCTION BOX ABOVE <br /> � LP-9 LP-9 <br /> 352 LP 2 352 ACCESSIBLE CEILING. <br /> LPE-1 352 26 9/ 0 20 <br /> 369 PROVIDE FLOOR BOX TYPE'B'FOR LOW VOLTAGE CONDUIT. <br /> FOOD ® ® ® ® ® I LPE-1/9 9 MOUNT FLOOR BOX CENTERED ON ACCESS PANEL BELOW POS <br /> SERVING FOOD COUNTER. REFER TO DETAIL 2/E521. <br /> 123 SEATING 164 J 370 PROVIDE FLOOR BOX TYPE W. MOUNT FLOOR BOX CENTERED ON <br /> o ❑g ( 124 B LPE 1/9 ACCESS PANEL BELOW POS COUNTER. REFER TO DETAIL 1/E521. <br /> O 426 JUNCTION BOXES AND FLEXIBLE CONDUIT RACEWAYS ARE <br /> ❑ 174 PREINSTALLED IN GUEST SERVICE COUNTER IN EACH POS <br /> / \ SECTION FOR POWER AND SYSTEMS DEVICES, PROVIDE WIRING, <br /> I ( a ❑ DEVICES, COVERPLATES AND FINAL ELECTRICAL CONNECTIONS AS <br /> � R 177 17 17 17 177 SHOWN AND PER ELECTRICAL SPECIFICATIONS. <br /> I 430 PROVIDE PULL BOXES FOR POWER AND SYSTEMS UNDER BASE <br /> I DECK AT EACH POS FIXTURE LOCATION, MOUNT PULL BOX ON TOP <br /> OF FINISHED FLOOR, BELOW FIXTURE ACCESS OPENING. <br /> > O 164 CONNECT POS PREINSTALLED FLEXIBLE CONDUITS TO PULL <br /> _ BOXES. <br /> I LPE-1/ 476 PROVIDE 3/4"IMC THRU EXTERIOR WALL FOR POWER CONNECTION <br /> I I I I I TO EACH SIGN LETTER. COORDINATE EXACT LOCATION OF <br /> o I PENETRATION AND SIGN REQUIREMENTS WITH SIGN VENDOR AND <br /> `l GC. REFER TO 5/E521. <br /> E:I- <br /> O810 UNKNOWN OR UNSURE CIRCUIT.CONTRACTOR SHALL FIELD <br /> VERIFY CIRCUIT NUMBER AND LOCATION AND RECORD ON <br /> BUILDING AS-BUILT DRAWINGS, PANEL SCHEDULES AND <br /> DIRECTORIES. O Qp,OF 5/pNq <br /> `` • Go9 <br /> Ll I I/Ift L �J <br /> COFFEE <br /> B u FOOD SALES - LU 181 Z rn <br /> SERV 1 B <br /> STORAGEFO <br /> qT FCTR�O Q� <br /> 120 PRY <br /> ❑B e 120A B F OF CF L A��FC <br /> o III';;";;"; �� <br /> LP 9/26 LP-9/26 <br /> E> M:�(� • <br /> 7/0- C LP-7/5 LP-5/31 n <br /> 0 LP-7/5❑ LP-7/5 LPE-1/14 LP-5/31 LP 5/37 1/17/2019 <br /> 3/4"C-2#10,1#10G <br /> 117 <br /> J ❑ C,'. <br /> AP LPE-1 <br /> LPE-1 CCN OFFICE 352 15,17 JNT <br /> 14 11 B ❑B 111 C �' LP-5 O <br /> 352 <br /> LP-7 LP-5/31 352 37 J 6" 12' 2 1/4" <br /> JANITOR 5 0 3'-21/2" 3/4"C-2#10,1#10G UD <br /> 119 B 352 LP 5 1 1/4"C 3/4"C 426 LP-8 1 1/4"C. <br /> 31 PIC LPE-1 <br /> II � 810 352 10 J 3/4"C 1 1/4" �, TYP 26 <br /> LO <br /> 48" LP-5/31 ' 43011 <br /> LPE-1/10 370 430 LP-6/13 336 z <br /> LP 10A P 10BLPE-1/15 <br /> B A LP 8/26 a <br /> TYP L.L <br /> ` LED SIGN LP-8/26 0 <br /> 234 232 426 i 370 RCPT <br /> B A LPE-1/17 LPE-1/17 <br /> LPE-1/15 LLPE-1/15 <br /> 369 LPE-1/17 GUEST <br /> 1-1/4 C 231 ® i i LP 6/13 i i 369 <br /> i i LED SIGN SERVICES J <br /> CIRCULATION i--4 LPE-1/10 336 i i 3/4"C RCPT � 367 3/4"C ,r; 103 TO LP-6/13 <br /> 107 i 367 336 i a, <br /> 368 1 1/4"C i i 368 1 1/4"C A F_ LP-6 � ( > <br /> __\ q q 13 v <br /> J ` 52(LU ALU 52° 81 W J� J�(15J J5 3/4"C-2#10,1#10G ^ ` <br /> TO LPE 1/15,17 LP-5/21 LP-5/21 45'45"45'45'45"PO r <br /> LP-6/24 LP-6/24 — LP-5/40 S S S F F f , <br /> EWC � 314 <br /> � LP-5 TO LPE-1/15,17 1 1/4"C <br /> GFCI GFCI 352 40 U Q <br /> CARTS 3/4"C-2#10,1#10G <br /> UJ— 101A LP-5 <br /> 355 � ENTRY EXIT 21 FLEXIBLE <br /> LP-6 '0 <br /> VESTIBULE VESTIBULE FULFILLMENT <br /> 24 <br /> TAR T BU YE SIGN 101 101B 103A A F <br /> 0 <br /> MEN WOMEN � LJ. <br /> ❑B 115 ❑B J <br /> E I W <br /> J J PDB J 156 J 156 L—L W <br /> LP-8/10 <br /> LP-8 <br /> 35 1.xz <br /> 476 10 <br /> 155 O <br /> C) <br /> AFG <br /> A O 108" I I I <br /> CA N <br /> 155 <br /> AFG <br /> 108" Project Number T-0738 <br /> Config: LL <br /> Drawn By G.F I KRAT <br /> O <br /> I <br /> Checked By B.H U NT <br /> I <br /> ENTRY POWER & <br /> SYSTEMS PLAN <br /> 3 �4 <br /> 1 CHECKLANES ENTRY & GUEST SERVICE POWER & SYSTEMS PLAN <br /> E311 SCALE: 1/4" = 1'-0" <br /> PLAN NORTH <br /> 1/17/2019 11:41:35 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.