DEMOLITION KEYNOTES GENERAL NOTES <br /> �A EXISTING ELECTRICAL DEVICES IN THIS AREA TO BE REMOVED A. REFER TO SHEET E601 FOR EMS CONTROLLED CIRCUITS. <br /> UNLESS NOTED OTHERWISE.MAINTAIN CIRCUITS ABOVE CEILING <br /> FOR RE-USE.PROVIDE NEW DEVICES AS INDICATED.ANY B. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER <br /> DEVICES SHOWN AS GREY TONE ARE EXISTING TO REMAIN,ALL CIRCUIT. <br /> OTHERS TO BE REMOVED. <br /> C. REFER TO SHEET E521 FOR FLOOR BOX DETAILS. <br /> EXISTING ELECTRICAL DEVICES IN THIS AREA TO REMAIN. <br /> D. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO TARGET® <br /> DEVICES SHOWN AS GREY TONE ARE EXISTING TO REMAIN. OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. <br /> EXTEND EXISTING CIRCUIT TO NEW DEVICES AS INDICATED. <br /> E. UNDER SLAB CONDUIT SHALL BE 3/4"MINIMUM. 1000 NICOLLET MALL <br /> F. COORDINATE&FIELD VERIFY FINAL LOCATIONS OF ALL TOUCH MINNEAPOLIS, MN 55403 <br /> FREE RECEPTACLES&BOXES WITH PROJECT ARCHITECT, <br /> ARCHITECTURAL PLANS AND ELEVATIONS. INSTALL PER <br /> EXISTING FIRE ALARM DEVICES MANUFACTURER'S RECOMMENDATIONS AND REQUIREMENTS. <br /> [F REVISE EXISTING FIRE ALARM DEVICE LOCATIONS IN THIS ROOM G. REFER TO SPECIFICATIONS FOR CONDUIT SUPPORT FROM ROOF <br /> THAT ARE LOCATED ON EXISTING WALLS OR CEILINGS THAT ARE STRUCTURE. <br /> REMOVED/REVISED.RELOCATE DEVICE TO NEAREST <br /> EXISTING/NEW WALL OR EXISTING/NEW CEILING THAT WILL H. REFER TO SPECIFICATIONS FOR TYPE MC CABLE SUPPORT FROM <br /> MEET ALL APPLICABLE REQUIREMENTS OF NFPA 72 AND THE STRUCTURE. <br /> AUTHORITY HAVING JURISDICTION. NEW DEVICES MAYBE <br /> REQUIRED IF EXISTING DEVICES ARE NOT SUITABLE FOR I. REFER TO SPECIFICATIONS LOW VOLTAGE CABLE SUPPORT D C ENGINEERING <br /> RELOCATION. LOCATION. <br /> Careful listening. Dynamic solutions. <br /> J. ELECTRICAL CONTRACTOR TO PROVIDE J-BOX FOR TEMP <br /> SENSORS IN FINISHED WALLS. REFER TO THE MECHANICAL www.dcengineering.net <br /> PLANS FOR RTU AND VAV TEMP SENSOR LOCATIONS. Phone:208.288.2181 Project:1 8TAR1 7 <br /> KEYNOTES <br /> # DESCRIPTION <br /> 211 RELOCATED CONTROLLED ACCESS EQUIPMENT(PUSHBUTTONS, <br /> INTERCOM,SWITCHES, ETC)SALVAGED FROM REMOVAL OF <br /> EXISTING TSC DESK. EXTEND EXISTING WIRING TO NEW <br /> LOCATION. FIELD VERIFY ALL EXISTING LOW VOLTAGE DEVICES <br /> TO RELOCATE. <br /> 234 RE-USE EXISTING EAS POWER SOURCE RETAINED FROM <br /> DEMOLITION OF OLD. <br /> 336 MOUNT JUNCTION BOX ABOVE ACCESSIBLE CEILING SPACE. <br /> 6 T 338 STUB CONDUIT(3/4"OR AS NOTED)FROM J-BOX TO AREA ABOVE <br /> CEILING LINE OR ABOVE BOTTOM OF ROOF SUPPORT MEMBER IN <br /> UNFINISHED AREAS. <br /> 352 EXISTING HOMERUN LOCATED ABOVE CEILING/IN JOIST SPACE <br /> SHOWN FOR REFERENCE. PROVIDE CONNECTION TO <br /> NEW/RELOCATED DEVICE/LIGHT FIXTURE. <br /> 372 EXTEND EXISTING DETEX CIRCUIT. <br /> 34" p 480 PROVIDE JUNCTION BOX RECESSED IN WALL,6"AFF, FOR <br /> ,qqUSB I B ELECTRICAL IN FURNITURE SYSTEM. PROVIDE METAL <br /> USB ALU -5COVERPLATE W/CENTER KNOCKOUT. <br /> 3 " LP-5/7 LP-5/7 LP5/7I 481 PROVIDE POWER CONNECTION TO FURNITURE SYSTEM. <br /> F 3 3" FURNITURE SYSTEM USES TWO CIRCUITS. ELECTRICAL <br /> CONTRACTOR TO COORDINATE OUTLET LOCATIONS AND <br /> CONNECTIONS WITH FURNITURE VENDOR. Date No. Description <br /> C:1El 482 LOW VOLTAGE CONTRACTOR TO ROUTE TEL/DATA CABLES IN 01/17/2019 PERMIT SET <br /> CIRCULATION STORAGE FURNITURE RACEWAY AND PROVIDE DATA PLATE COVERS. <br /> 117 160 FB-] 483 LOW VOLTAGE CONTRACTOR TO ROUTE TEL/DATA CABLES IN <br /> STL FURNITURE SYSTEM RACEWAY TO 4 PORT FACE PLATE PROVIDED <br /> OFFICE WITH FURNITURE SYSTEM. <br /> 161 A F LP-5/7 484 INSTALL RECEPTACLES FURNISHED BY FURNITURE VENDOR. <br /> 485 PROVIDE CONNECTION TO DOOR STRIKE. <br /> I I 486 VOICE/DATA CONTRACTOR: PROVIDE RG-11 COAXIAL CABLE FROM <br /> LOUNGE TV TO EXISTING ANTENNA MAST ON ROOF. <br /> 488 PROVIDE 2-GANG JUNCTION BOX AT 44"AFF FOR TSC STORAGE <br /> I I LP-5 352 DOOR STRIKE RELEASE PUSHBUTTON AND KEYSWITCH.PROVIDE <br /> LP 5/7 7 I 1/2"C W/2#14 TO STRIKE SOLENOID. REFER TO SPECIFICATION <br /> LP-5 SECTION 08 7100 HARDWARE GROUP 63 FOR PUSHBUTTON AND <br /> KEYSWITCH. DOOR STRIKE RELEASE PUSHBUTTON TO BE <br /> LOCATED A MINIMUM OF 8'-0"FROM TSC STORAGE ROOM DOOR. <br /> LP-8 CIRCULATION 489 INSTALL POWER SUPPLY AND OTHER DEVICES FURNISHED WITH <br /> 118 HARDWARE. PROVIDE CONDUIT,J-BOXES AND WIRING. <br /> 484 484 490 INSTALL JUNCTION BOX AT 18"AFF FOR MULITOUTLET ASSEMBLY. <br /> PROVIDE A 5'-0"LONG MULTIOUTLET ASSEMBLY WITH SINGLE <br /> LP- 483 483 LP-5 RECEPTACLE SPACING AT 6".MOUNT MULTIOUTLET ASSEMBLY <br /> OPEN 352 VERTICALLY ON WALL. <br /> J 1,3,5 <br /> OFFICE F- - - - - - - - -I F _ - I- - - - 491 TIME&ATTENDANCE MACHINE(OFME G10). PROVIDE DOUBLE <br /> LP-9 F B 162 i LP-5/22 1 1LP-5/20 1 LP 5/1 I GANG BOX WITH BARRIER NEMA 5-20R'DECORA'STYLE SIMPLEX <br /> -1 C NFER RECEPTACLE AND TELEPHONE'DECORA'COVERPLATE <br /> 1 LP-5/3 1 � 163 B (80479-430SS OR EQUAL)AT 35"AFF. <br /> Me�LP-5/1 STORAGE 504 CONNECT TO TRANSFER FAN NOTED. <br /> 1 LP-5/321 1 �� 1 I 164 �B 791 ELECTRICAL CONTRACTOR TO VERIFY EXISTING DOORBELL AT <br /> 1 - 1 1 1 RECEIVING DOOR IS OPERATIONAL PRIOR TO NEW WORK <br /> LP-5/22 1 iLP-5/20�r/ 1 ❑C PERFORMED AND AGAIN AFTER THE REMODEL IS COMPLETE. <br /> USB "1~ r 1 '1 TP- %6 36'B LP-5/1 L 7 WORK WITH STORES PMT TO PERFORM THE COMMISSIONING OF <br /> II LPI 5/32 I FnEXISTING DOORBELL. DURING GENERAL DEMO WORK THE <br /> ,ILP 5/5_ LP 5/5 C _ _ J C � _ _ _ _ - _ _ 1 LP 5/1- ELECTRICAL CONTRACTOR SHOULD VERIFY THAT THE BUZZER <br /> LP 5/5 LP-5/5 USB J J USB USB(R J J USB LP-5/1 <br /> 44" 44" 44" 4 AND TRANSFORMER LOCATED ON THE INTERIOR OF THE STORE IS <br /> LC LP 5/32 LP 5/3 LP 5/20 _LP 5/3 NOT REMOVED. <br /> 810 UNKNOWN OR UNSURE CIRCUIT.CONTRACTOR SHALL FIELD <br /> 338 48 482 480 481 VERIFY CIRCUIT NUMBER AND LOCATION AND RECORD ON <br /> LP 5 481 480 1 1/4"C 482 480 338 3/4"C-4#10,1#10G BUILDING AS-BUILT DRAWINGS, PANEL SCHEDULES AND <br /> DIRECTORIES. <br /> 22,32 3/4"C-4#10,1#10G LP-5 <br /> 20,36 <br /> 2 OFFICE POWER & SYSTEMS PLAN <br /> E321 SCALE: 1/4" = 1'-0" <br /> Qp,OF 5/ <br /> �� • Gp,� <br /> cU Zrn <br /> m <br /> 181 <br /> * 3 � <br /> OF C4I, <br /> 4 5 <br /> 1/17/2019 <br /> 20'-11 1/2" <br /> 486 338 <br /> LP-5/12 B C) <br /> USB 36" 36" 7g"J d USB 36 USB 36" C LP-5/14 <br /> LP 5/12 LP 5/12 V1 78" -P-5/12 LP 5/12 LP-5/12 LP 5/12 LO <br /> ICR �I <br /> GFCI <br /> LP-8/1556 ' Ll13 (L] E <br /> r� GFCI � � E501 � � <br /> LP-5/17 LP-8/2 <br /> UJ <br /> M L.L <br /> 34 CEIE L Ll d E <br /> _ LP-5/17 GFCI <br /> ❑C LP-5/9 LP-5/9( (BUSB LP-8/1 ]� ED I I O <br /> LP-5/9 COATS/ J T Ll 77� ED <br /> LOCKERS LP-5/14 � J <br /> 151 <br /> CONTROL [B 3/4"C-6#10,1#10G ❑ <br /> " <br /> ROOM FFF <br /> P_5/9 LP-8 LOUNGE <br /> 114 �g LP 5/9 C LP-5 352 1'2'15 157 B F v <br /> 2 I E 156 R B 11,13,15,17 <br /> LP-5 <br /> E511 W 0 0 0 0 <br /> LP-5 LP-5/13 352 10,12,14 <br /> 7 234 I 352 LP-8 TRAINING U Q <br /> S(a) 9 I �C LP-5/9 22 F B 158 SIM <br /> 352 LP-5 ( L LP-5/15 13 <br /> J <br /> CASH 27 LP-2/27C o MUH <br /> E501 <br /> --OFFICE 338 491 L J J 3/4"C-2#10,1#10G 8' 6 1/8" <br /> VESTIBULE 2 TF-3 485 W W C LP 5/11 LP 8/22 W C <br /> 104A 48„ E511 MSS 489 LP 2 I u LP-5/10 LP-5/10 C 78" �P 5/14 <br /> S 810 352 27 (p � W <br /> J I �I <br /> VENDING VENDING LP-5/14 <br /> LP 5/27 CIRCULATION <br /> 60" 60" <br /> 504 J LPE-1/30 484 108 GFCI GFCI J <br /> 338 I LP-5/27 eLP <br /> TF-3 <br /> 96" J V <br /> 0 LPE-1/30 LP-5/23 LP-5/34 LP-5/23 LP-5/34 <br /> CAH 372 7 <br /> OFFICE J LP 5 483 _ Z <br /> r� <br /> LP 5/27 104 B 490 TSCSTOUIPR M�E� 30 352 I a 211 <br /> 352 LPE 1 LP-5/30 110 Ell <br /> TMSC h 0 1 <br /> 18 A❑ F B 109 00 <br /> N <br /> 771 <br /> I <br /> 490 488 LP-5 J <br /> 0 336 LP-5/30 490 352 34 <br /> 12"12" LP-5/27 LP-5/38 LP-5/35 LP-5 <br /> LPE-1/18(py 60" J G �_G G G K J "Ry 23 352 Project Number <br /> CCN LP-8/24 <br /> 1/4"C 482 480 338 481 480 T0738 <br /> 3/4"C-2#10,1#10G LP-5 <br /> LP-8 Config: LL <br /> - 735-38 v G.FIKRAT <br /> 19 24 352 791 Drawn B <br /> 73/4"C-2#10,1#10G <br /> Checked By B.H U NT <br /> 1 OFFICE POWER & SYSTEMS PLAN <br /> E321 SCALE: 1/4" = 1'-0" <br /> OFFICE POWER <br /> SYSTEMS PLANS <br /> E321 <br /> PLAN NORTH <br /> 1/17/2019 11:41:39 AM <br />