My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
2800 - Aboveground Petroleum Storage Program
>
PR0515721
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2019 11:48:10 AM
Creation date
2/28/2019 11:15:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515721
PE
2832
FACILITY_ID
FA0007101
FACILITY_NAME
FORWARD INC LANDFILL
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
01
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AST SP001 ANNUAL INSPECTION <br /> General Inspection Information: <br /> (36 months from inspection <br /> Inspection Date: 124/2019 Retain Until Date: 1/24a022 date) <br /> Prof lnspedion Date: Unavailable Inspector Name: Philip Thiel <br /> Tanks Inspecled(IDws):Used Oil WASTE OIL <br /> Inspection Guidance: <br /> ➢ For equipment not included in this standard,follow the manufacturer recommended inspection/testing schedules and <br /> procedures. <br /> ➢ The periodic AST Inspection is intended for monitoring the external AST condition and its containment structure.This visual <br /> inspection does not require a Certified Inspector. It shall be performed by an owner's inspector who is familiar with the site <br /> and can identify changes and developing problems. <br /> ➢ Remove promptly upon discovery standing water or liquid in the primary tank,secondary containment area,interstice,or <br /> spill container. Before discharge to the environment,inspect the liquid for regulated products or other contaminants and <br /> disposed of it properly. <br /> In order to comply with EPA SPCC(Spill Prevention,Control and Countermeasure)rules, a facility must regularly test liquid <br /> level sensing devices to ensure proper operation(40 CFR 112.8(c)(8)(v)). <br /> L Non-conforming items important to tank or containment intearity require evaluation by an engineer experienced in AST <br /> design, a Certified Inspector,or a tank manufacturer who will determine the corrective action.Note the non-conformance and <br /> corresponding connective action in the comment section. <br /> ➢ Retain the completed checklists for 36 months. <br /> r Complete this checklist on an annual basis supplemental to the owner monthly-performed inspection checklists. <br /> 's Note: If a change has occurred to the tank system or containment that may affect the SPCC plan,the condition <br /> should be evaluated against the current plan requirement by a Professional Engineer knowledgeable in SPCC <br /> development and implementation. <br /> Item Task Status <br /> 1.0 Tank Containment <br /> 1.1 Containment structure Is structure free of: r Yes r No r N/A <br /> • Holes or cracks in containment wall or Floor A Yes r No I-N/A <br /> • Washout I+Yes r No r N/A <br /> • Liner degradation <br /> r <br /> • Corrosion Yes r No r N/A <br /> • Leakage r'Yes r No r N/A <br /> • Paint failure r Yes r No r N/A <br /> • Tank settling rYes r-No r-NIA <br /> Comments: <br /> 2.0 Tank Foundation and Supports <br /> 2.1 Foundation No observed settlement or foundation washout? P Yes r No <br /> 2.2 Concrete pad or ring wall No visible cracking or spalling? A Yes r No r N/A <br /> 2.3 Supports No visible corrosion,paint failure,etc.? r Yes r No r N/A <br /> 2.4 Water drainage Water drainage away from tank? A Yes r No r N/A <br /> 2.5 Tank grounding Strap secured and in good cendilion? r Yes P Nor N/A <br /> If intrinsically ground, please note in comments. <br /> Comments: <br /> WO: 6703239 SEPTEMBER2016 <br />