Laserfiche WebLink
INDIVIDUAL TANK INFORMATION AND <br />pp Tankno/ogy <br />TEST DATE: 09/08/03 8900 SHOAL CREEK, BUILDING 200 <br />CLIENT: VEEDER ROOT - CMS AUSTIN, TEXAS 78757 (512) 451-6334 <br />TEST RESULTS <br />WORK ORDER NUMBER: 2228368 <br />SITE: SAFEWAY 2600 <br />Printed 10/14/2003 09:18 MSHAW <br />TANK INFORMATION <br />Tank ID: 91 3 <br />Tank manifolded: NO <br />Bottom to top fill in inches: <br />187.0 <br />Product: PREMIUM <br />Vent manifolded: YES <br />Bottom to grade in inches: <br />193.0 <br />Capacity in gallons: 10,037 <br />Vapor <br />recovery manifolded: YES <br />Fill pipe length in inches: <br />67.0 <br />Diameter in inches: 120.00 <br />Overfill protection: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 207 <br />Overspill protection: YES <br />Stage I vapor recovery: <br />DUAL <br />Material: DW STEEL <br />Installed: ATG <br />Stage II vapor recovery: <br />ASSIST <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: <br />VPLT <br />LEAK DETECTOR TEST RESULTS Test method: FTA <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />UFT/OFT: <br />Make: <br />VEEDERROOT <br />Fluid volume in gallons: <br />Model: <br />L.L.D. <br />Tank water level in inches: <br />S/N: <br />ELECTRONIC <br />Test time: <br />NOT <br />Open time in sec: <br />Number of thermisters: <br />TESTED <br />Holding psi: <br />NOT <br />Specific gravity: <br />Resiliency cc: <br />TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: <br />189.0 <br />Determined by (method): <br />Metering psi: <br />Leak rate in gph: <br />Calib. leak in gph: <br />3.00 <br />Result: <br />Results: <br />PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: UTS-4T <br />LINE TEST RESULTS <br />Test type: PTx-88 <br />Test time: <br />Material: APT <br />FLEXIB APT FLEXIB <br />Ullage volume: <br />Diameter (in): <br />1.5 1.5 <br />Ullage pressure: <br />Length (ft): <br />125.0 125.0 <br />Results: <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />DATA FOR UTS4T ONLY: <br />Test 1: Start time: <br />Time of test 1: <br />Finish psi: <br />NOT NOT NOT <br />NOT <br />Temperature: <br />NOT <br />Vol change cc: <br />Test 2: Start time: <br />TESTED TESTED TESTED <br />TESTED <br />Flow rate (cfh): TESTED <br />Finish psi: <br />Time of test 2: <br />Vol change cc: <br />Test 3: Start time: <br />Temperature: <br />Finish psi: <br />Flow rate (cfh): <br />Vol change cc: <br />Time of test 3: <br />Final gph: <br />Temperature: <br />Result: <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />COMMENTS <br />Pump make: FE PETRO <br />COMMENTS <br />Impact Valves Operational: YES <br />Printed 10/14/2003 09:18 MSHAW <br />