Laserfiche WebLink
FEE -04-2009 20:21 Service Station Systems <br />Monitoring System Certification - P?- ? of 3 <br />Site Address: 1804 West 11Th. Street A Corral Hallow <br />ID. Results of Testing / Servicing <br />Software Version lnstalle& <br />Comnlete the following checklist: <br />408 938 8888 P.04 <br />Date of Testing/Servicing: 12/29/08 <br />vYes <br />❑ No* <br />Is the audible alarm operational? <br />Yes <br />❑ No* <br />Is the visual alarm operational? <br />Or Yes <br />p No* <br />Were all sensors visually ins ected, functionalIX tested, and confirmed operational? <br />OYes <br />❑ Nos <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />'j' Yes <br />13 No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g_ inodcm) <br />Q N/A <br />o erational? <br />19 Yes <br />❑ No* <br />For pressurized piping systems, docs the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If ves: which sensors initiate <br />positive shut -down'? ((;heck all that apply) `RJ, Suinp/Trench Sensors; V Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Yes ❑ No <br />VYes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le. no <br />❑ N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trier? % <br />❑ Yes* <br />qNo <br />Was any monitoring equipment replaced? Yves, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes* <br />G�No <br />Was liquid found inside any sLcondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product. ❑ Water. if yes, describe causes in Section F. below. <br />Yes <br />❑ No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach ser-zt re ports, i a > >licahle. <br />l9 Yes <br />Cl No* <br />is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments; <br />