FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
379
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JAN -20-2009 09:33 Service Station Systems 408 938 8888 P.06 <br />6_ gR.VONDARV P1PF TFSTINC <br />Test Method Developed By: ❑ Piping Manufacturer 0 industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: ® Pressure Q Vacuum ❑ Hydrostatic <br />Q Other (Specify) <br />Test Equipment Used: Test reducer boots, Nitrogen and gauges Equipment Resolution: 0.5% of span <br />Piping Run # 91 A Piping Run # 91 B <br />Piping Material: <br />Fiberglass Fiberglass <br />Piping Manufacturer: <br />Western Fiberglass Western Fiberglass <br />Piping Diameter: <br />2" 2" <br />Length of Piping Run: <br />150' 150' <br />Product Stored: <br />Gasoline Gasoline <br />Method and location of <br />i in -run isolation: <br />Reducer Bootsinttings Reducer Boots/Fittings <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 minutes 10 minutes <br />Test Start Time: <br />8:30 am <br />Initial Reading (R,): <br />5 psi <br />Test End Time: <br />9:30 am <br />Final ReadingR : <br />( F) <br />5 psi <br />Test Duration: <br />1 br_ <br />Change in Reading (Rt.-&): <br />none <br />Pass/Fail Threshold or <br />Criteria. <br />No detectable Loss <br />Test Result: <br />® Pass Fail Pass 0 Fail <br />Comments — (include in brmation on repairs made prior to testing, and reconunended.follow-up fnr ailed tests) <br />Torn boot <br />