My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department "j, ''' <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 / 160 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.or /q ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />Safeway Fuel Center #2600 <br />1987 W ELEVENTH ST, Tracy <br />June 21, 2016 <br />UST System Observations <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V ❑ R n COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms are not current in CERS. <br />-The diesel tank form states the diesel tank has single walled vapor recovery piping. Diesel does not have vapor <br />recovery. <br />-The diesel tank form states the riser is double walled with a fiberglass secondary. The 87 and 91 tank forms state <br />the riser is double walled with a steel secondary. The 91 and diesel tanks are both part of the same split tank. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required and accurate information, and submit for review by the EHD. <br />This is a Class II violation. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The map submitted on CERS doesn not include the <br />dispenser sensors. A site plan must be submitted identifying the locations where monitoring will be performed. <br />Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload <br />a copy of the UST Monitoring Site Plan. <br />This is a repeat violation, Class II. <br />204 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved, current copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.