My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. PIPING SUMP TESTING <br />Test Method Developed By: ❑ Sump Manufacturer ❑✓ Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: E] Pressure ❑ Vacuum ❑✓ Hydrostatic <br />E] Other (Spec) <br />Test Equipment Used: Incon Sump Tester <br />Equipment Resolution: +/- 0.002 Inches <br />Sump # 87 Sump # 91 <br />Sump # Diesel Sump # <br />42" <br />Sump Diameter: 42" 42" <br />Sump Depth: <br />72" <br />73" <br />73" <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of <br />12" <br />12" <br />12" <br />Hi hest Piping Penetration: <br />Height from Tank Top to Lowest <br />14" <br />13" <br />13" <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Good <br />Good <br />Good <br />Portion of Sump Tested' <br />2" Above Piping <br />2" Above Piping <br />2" Above piping <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />[]Yes [:]No ❑✓ NA <br />[-]Yes ❑No✓❑NA <br />❑ Yes❑ No ENA <br />❑ Yes ao [:]NA <br />product and water)? <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail-safe <br />shutdown?' <br />❑Yes ❑No [DNA ❑Yes []No❑✓ NA ❑Yes❑ No [DNA [-]Yes []No [_]NA <br />Was fail-safe verified to be <br />[]Yes [:]No ✓❑NA <br />[-]Yes ❑No [Z]NA <br />[]Yes [-]No ❑✓ NA <br />❑ Yes ❑No ❑NA <br />o erational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />test: <br />Test Start Time: <br />1:55PM <br />11:49AM <br />1:05PM <br />Initial Reading (RI): <br />5.1162 Inches <br />2.5182 Inches <br />2.9917 Inches <br />Inches <br />Test End Time: <br />2:10PM <br />12:04PM <br />1:20PM <br />Final Reading (RF): <br />5.1146 Inches <br />2.5180 Inches <br />2.9905 Inches <br />Inches <br />Test Duration: <br />15 Minutes <br />15 Minutes <br />15 Minutes <br />Change in Reading (RF -RI): <br />0.0016 <br />0.0002 <br />0.0012 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />0.002 <br />0.002 <br />Test Result: <br />❑✓ Pass ❑Fail <br />0 Pass ❑Fail <br />✓❑Pass ❑Fail <br />❑Pass ❑Fail <br />Was sensor removed for testing? <br />❑✓ Yes []No []NA <br />[Z]Yes ❑No []NA <br />❑✓ Yes ❑No ❑NA <br />❑ Yes [-]No ❑NA <br />Was sensor properly replaced and <br />✓❑Yes ❑No ❑NA <br />❑✓ Yes []No ❑NA <br />✓❑Yes ❑No [_]NA <br />❑ Yes [-]No ❑NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Diesel STP sump torn test boot, replaced boot, retest and passed. <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment <br />testing scope of work". <br />RECCIVED <br />OCT 2 19 2017 <br />ENVIROMICN-,AL HEALTH <br />9ERMIT/SERIn,,FS <br />