My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN -� dj�,—�$ <br />M Environmental Health Department <br />COUNTY <br />FA0013503 PRO517565 SCO01 06/12/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />SAFEWAY FUEL CENTER #2600 <br />Facility Address: <br />1987 W ELEVENTH ST, TRACY <br />Date: <br />June 12, <br />2018 <br />UST System Observations <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />■ V <br />❑ R ■ COS <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V <br />❑ R o COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V <br />❑ R ❑ COS <br />322 <br />HSC 25281.61 <br />Unburied below grade emergency generator system failed to meet exemption status <br />o V <br />o R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V <br />❑ R ❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V <br />❑ R o COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />o V <br />❑ R in COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V <br />❑ R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V <br />❑ R ❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V <br />in R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />❑ V <br />❑ R ❑ COS <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V <br />❑ R ❑ COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />❑ V <br />❑ R ❑ COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />❑ V <br />❑ R o COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V <br />❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />in V <br />❑ R in COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V <br />❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V <br />❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />V <br />R COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />108 <br />CCR 2637(f), 2638(e) Failed to notify the EHD 48 hours prior to conducting testing. <br />Secondary containment testing was performed on 6/8/2018 without providing notification to the EHD at least 48 <br />hours in advance. Notification shall be provided to the EHD at least 48 hours in advance of testing. Ensure to notify <br />EHD 48 hours prior to conduct testing. <br />This is a Class II violation. <br />FA0013503 PRO517565 SCO01 06/12/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 3 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 952051 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.