2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. FILL RISER CONTAINMENT SUMP TESTING <br />Facility is Not Equipped With Fill Riser Containment Sumps m <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer m Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Incon Sump Tester Equipment Resolution: +/- 0.002 Inches <br />Fill Sump # 87 Fill Sump # 91 Fill Sump # Diesel Fill Sump # <br />Sump Diameter: 42" 42" 42" <br />Sump Depth: <br />72" <br />72" 72" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />18" <br />18" 24" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />21 „ <br />21 „ 22" <br />Condition of sump prior to <br />testing: <br />Good <br />Good Good <br />Portion of Sump Tested <br />2" Above Piping <br />2" Above Piping 2" Above Piping <br />Sump Material: <br />Fiberglass <br />Fiberglass Fiberglass <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 Minutes <br />30 Minutes 30 Minutes <br />30 Minutes <br />Test Start Time: <br />8:28AM <br />8:28AM 8:28AM <br />Initial Reading (RI): <br />3.9942 Inches <br />2.6226 Inches 5.4361 Inches <br />Inches <br />Test End Time: <br />8:43AM <br />8:43AM 8:43AM <br />Final Reading (RF): <br />3.9953 Inches <br />2.6225 Inches 5.4366 Inches <br />Inches <br />Test Duration: <br />15 Minutes <br />15 Minutes 15 Minutes <br />Change in Reading (RF -RI): <br />0.0011 <br />0.0001 0.0005 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />0.002 0.002 <br />0.002 <br />Test Result: <br />2 Pass ❑ Fail <br />p Pass ❑ Fail p Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Is there a sensor in the sump? <br />W1 Yes ❑ No <br />❑ Yes ❑ No m Yes ❑ No <br />❑ Yes ❑ No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />❑ Yes ❑ No p NA <br />❑ Yes ❑ No Z NA ❑ Yes ❑ No p NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor removed for testing? <br />m Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA m Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />© Yes ❑ No ❑ NA <br />p Yes ❑ No ❑ NA O Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment <br />testing scope of work". <br />