My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br /> it <br /> NOV 14 2014 <br /> 5.SECONDARY PIPE TESTING 'AL HEALTH <br /> -rest Method Developed By: 0 Piping Manufacturer Industry Standard ❑ Professi nal,l ngi <br /> SO q�4EFNT <br /> El Other(Sped& <br /> Test Method Used: 23 Pressure [3 VaCLIUM CD Hydrostatic <br /> 0 Other(Spectfy) <br /> Test Equipment Used: Test reducer boots,Nitrogen and gauges Equipment Resolution:0.5%of span <br /> J <br /> Piping Run 0 87 Piping Rijn P 91 Piping Run 4 Diesel <br /> Piping Material: Poly Poly Poly <br /> Piping Manufacturer: Western Fiberglass Western Fiberglass Western Fiberglass <br /> Piping Diameter: 2-1 2" 2" <br /> Length of Piping Run: 100, 100* 100, <br /> Product Stored: Gasoline Gasoline Diesel <br /> Method and location of Rcduccr Bw_4;Fimngq Reducer lloots/Fiiiitigs Reducer liwis/Rifings <br /> piping-run isolation: <br /> Wait time between applying <br /> pressure/vacuum/water and 10 minutes 10 minutes 10 minutes <br /> startintest: <br /> Test Stan Time: 9:00 am 9:00 am 9:00 am <br /> Initial Reading(Rj): 5 psi 5 psi 5 psi <br /> Test End Time: 10.00 am 10:00 am 10.00 am <br /> Final Reading(RF)-. 5 psi 5 psi 5 psi <br /> Test Duration: I lir. I hr. I hr. <br /> Change in Reading(Rr-R[): None None None <br /> Pass/Fail Threshold or <br /> Criteria: No detectable Loss No detectable Loss No detectable Loss <br /> Test Result; IK Pass Fail 0 Pass 0 Fail El Pass 0 Fail- <br /> -Comments (include iqforinufion on repairs made priar to testing, and recommendecl fbllow-u fiorftiled testa) <br /> ........... <br />