COMPLIANCE INFO 2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO 2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:31 AM
Creation date
2/28/2019 4:45:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+� . Maintenance History Service Station Systems <br /> 680 Quinn Ave. <br /> .. Shell 135997 San Jose,CA 95112 <br /> ABEE <br /> 1455 The Alameda @ Hester in San Jose License#:4851$4 <br /> 8114/14 to 11114!14 <br /> Job At Release Ref# Finished Tech Hold Status Tasks <br /> others and in good shape,fittings also installed with permatex. In formed mgr <br /> about 3/4,said was OK to leave as is. Does no want ST-30 at this time,alarm <br /> has 4 more days. 1 week hold.Third tech,Jesse,9/12/14 JAR:Ran st-30 test <br /> and found vapor swivel adapter leaking on T-2 plus.After repairs retest again test <br /> pass,cleared alarm.Had to remove vapor bucket and put on vise to separate <br /> vapor adapter from bucket.John T-Dialed into site and found leak rate 9CFH. <br /> See attachment.Need to run a 10"st30. <br /> Tech:9/29/14 SDM:9/25/14 Daniel B:Assisted on site with SSS with a lift,took <br /> apart copper piping on D1/2,5/6 and 7/8,sealed them with pipe dope. <br /> 9/25/14 A?B:ran 10 in test found TLM cap leaking vapor tank 1 regu.tank 3 91 <br /> vapor adapter leaking vapor on top replace part and disp 1-2 5-6 7-8 below the <br /> vapor shear valve the copper piping leaking from the fitting remove piping reflare <br /> copper on disp 1-2 5-6 7-8 retest pass cleared alarm all function normal <br /> Billing: 10/16/14 SEP'.Work order#1376097 to Kim. <br /> 10/9114 KTL:ABle invoice in holding folder for SSS 1376097 <br /> 10/3/14 JAM: Invoice sent to SSS. <br /> 9/29/14 SDM:Checked in Able paperwork/Bill to be sent to SSS <br /> 699815 Ethan Lim 9125114 DaveT Invoiced Designated Operator Insp,Compliance,Passed Verification, <br /> Tech:9/25/14 MSS:Completed DO inspection <br /> Billing: 1011114 ARJ:WO 1375526 to April <br /> 699495 Ethan 9112114 JesseR Invoiced Sensor-ISD Pressure,Warn-Vapor Leak,Reset[9106,1; <br /> Tech:9112/14 JAR: 1 week hold for this job. Static Pres.2 in.WC Test,Verification.Passed w/Repairs; <br /> Tank#02,Vapor Adapter,Damaged/Worn,Replaced(Same Model); <br /> 9112/14 JAR:Ran st-30 test and found vapor swivel adapter leaking on T-2 <br /> plus.After repairs retest again test pass,cleared alarm.Had to remove vapor i CD <br /> CD <br /> bucket and put on vise to seperate vapor adapter from bucket. < <br /> 697278 Ethan 9/9114 BryanKe Invoiced Sensor-ISD Pressure.Warn-Vapor Leak,Service Declined[6/25 6am]. r-+ <br /> "Dispatch:9/10114 JPP:W&M Notification sent to scc.wfs Static Pres.2 in.WC Test,Verification,Test Failed; <br /> Disp#04 Unihose,Nozzle Face Seal,Damaged/Worn,Replaced(Same Model), <br /> measures@aem.sccgov org <br /> Disp#06 Unihose,Hose,Damaged/Worn,Replaced(Same Model)[SITE HAS THE HOSE], o <br /> 911114 O?E:Emailed to Disp#05,Vapor Recovery,Permit Inquiry-Air,No Permit Needed: 4�- <br /> general@AbleMaintenarice.cam:rod@ablemainte nance.cam;bria n@ablemainten Disp#05,Vapor Recovery,Permit Inquiry-Building,No Permit Needed. <br /> ante.com;cheryl@ablemaintenance.com, Disp#05,Vapor Recovery,Leaking Vapor,Replaced(New Model) L <br /> 8/25/14 O?E:Ethan reports ISD Vapor Leak Warn today 6am <br /> Printed by DebbieW at 11/14/14 2.05pm Page-2- <br />