Laserfiche WebLink
San Joaquin Countywe <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />Safeway Fuel Center #2600 <br />1987 W ELEVENTH ST, Tracy <br />June 21, 2016 <br />UST System Observations <br />326 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R ❑ COS <br />328 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R ❑ COS <br />329 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />7 V i R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />c V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R ❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />Unlisted Design/Construction violation <br />❑ V ❑ R ❑ COS <br />2060 <br />See below <br />❑ V n R 7 COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms are not current in CERS. <br />-The diesel tank form states the diesel tank has single walled vapor recovery piping. Diesel does not have vapor <br />recovery. <br />-The diesel tank form states the riser is double walled with a fiberglass secondary. The 87 and 91 tank forms state <br />the riser is double walled with a steel secondary. The 91 and diesel tanks are both part of the same split tank. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required and accurate information, and submit for review by the EHD. <br />This is a Class II violation. <br />105 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The monitoring plan is not current and/or not approved by the EHD. The monitoring plans for all three tanks did not <br />include a response for "Leak Alarm Triggers Automatic Pump Shutdown" and "Failure/Disconnect Triggers Pump <br />Shutdown" and they incorrectly state that "UDC Monitoring Stops Flow of Product at the Dispenser." The monitoring <br />plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make <br />the necessary changes, and submit for review by the EHD. <br />This is a repeat violation, Class Il. <br />Page 3 of 5 <br />