Laserfiche WebLink
CAMBRIA <br /> ANALYTICAL RESULTS <br /> Tank excavation, dispenser island, product piping, and vent line soil sample analytical results <br /> are summarized in Table i and presented on Figure 2 The certified analytical reports are <br /> presented in Appendix A A summary of these data is presented below <br /> UST Area Initially, nine samples were collected at depths ranging from 14 to 17 fbg in the <br /> tank excavation Four of these samples (T6-N-14', T6-S-17', T7-N-17', and T7-S-17') <br /> contained elevated petroleum hydrocarbon concentrations These areas were over-excavated <br /> and resampled at 19 to 25 fbg No TPHd, benzene, or MTBE were detected in any of these <br /> samples TPHg was only detected in sample T7-N-24 5 at a concentration of 15 4 ppm <br /> Discolored soil was observed at the bottom of the southeastern portion of the tank <br /> excavation near tank sample T6-S This area was over-excavated to an approximate depth <br /> of 25 fbg and one soil sample (T6/7-5-20') was collected from the edge of the over- <br /> excavation between the diesel UST and the easternmost gasoline UST This sample <br /> contained 4 92 ppm TPHg and 52 9 ppm TPHd Benzene and MTBE were not detected <br /> iFormer Dispenser Area- Initially, four samples were collected at depths ranging from 3 to <br /> 4 fbg beneath the former dispensers These samples (DNE-3 5 , DSE-4 , DNW-3 , and <br /> DSW-3') contained TPHg concentrations ranging from <1 00 to 35 7 ppm, TPHd <br /> concentrations ranging from 8 65 to 3,850 ppm and MTBE concentrations ranging from <br /> <0 100 to 1 26 ppm Benzene was not detected in any of the samples Areas beneath three <br /> of the dispensers were over-excavated to approximate depths ranging from 7 to 8 5 fbg <br /> These deeper samples did not contain detectable concentrations of TPHg, TPHd or benzene <br /> MTBE was only detected in sample DNW-8 5' at a concentration of 0 0158 ppm <br /> Lateral over-excavation was performed near the southwestern dispenser island One soil <br /> sample (DSW1-3') was collected at the edge of the over-excavation It contained 23 7 ppm <br /> TPHd TPHg, benzene, and MTBE were not detected <br /> Product Piping- Initially, three samples (PLE1-5', PLE24', and PLW1-3 5 ) were collected <br /> below the former product piping alignment These samples contained TPHd at <br /> concentrations ranging from <1 00 to 23 3 ppm and benzene concentrations ranging from <br /> <0 00500 to 0 0164 ppm TPHs and MTBE ��ere not detected in the sampl« OiiL of thL�,c. <br /> areas was over-excavated (PLE2-8 5') and no TPHg, TPHd, benzene, or MTBE were <br /> Octected at that depth <br /> 241-1399 5 <br />