Laserfiche WebLink
— s <br /> n„ <br /> S [EC ® R <br /> • Conceptual Site Model <br /> March 24, 2004 <br /> Page 18 s <br /> was detected in groundwater at concentrations ranging from 688 pg/L (CPT-2 at 38 feet bgs) to <br /> 439,000 pg/L (CPT-4 at 47 feet bgs) Benzene was detected in groundwater at concentrations <br /> ranging from 1 52 pglL (CPT-2 at 30 feet bgs) to 13,200 pglL (CP74 at 47 feet bgs) MtBE was <br /> detected in groundwater at concentrations ranging from 29 4 pg/L (CPT4 at 47 feet bgs) and 842 <br /> pg/L (CPT-1 at 50 feet bgs) These activities are summarized in Cambria's July 20, 2000 Site <br /> Investigation Report <br /> P <br /> yl <br /> 9 <br /> In June of 2002, Cambria advanced seven soil borings (CPT-5 through CPT-11 to access the extent <br /> of hydrocarbons in soil and groundwater beneath the site Soil samples collected from CPT-5 <br /> reported TPHg, benzene and MtBE below laboratory reporting limits TPHg was detected in <br /> groundwater at concentrations ranging from 68 pg/L ( CPT-11 at 49 feet bgs) to 4,400 pg/L (CPT-11 <br /> at 65 feet bgs) Benzene was detected in groundwater at concentrations ranging from 0 73 pg/L <br /> (CPT-11 at 81 feet bgs) to 3,200 pg/L ( CPT-11 at 65 feet bgs) MtBE was detected in groundwater <br /> at concentrations ranging from 0 67 pg/L (CPT-6 and CPT-11 at 49 and 81 feet, respectively) to 36 <br /> pg/L (CPT11 at 65 feet) These activities are summarized in Cambria's January 21, 2003 Site <br /> Investigation Report <br /> Excerpts from the Shell service station reports are presented in Appendix N <br /> T-11 7.0 POTENTIAL GROUNDWATER RECEPTORS 1 <br /> A database search was conducted by EDR, on behalf of SECOR, to determine potential receptors of <br /> impacts from groundwater A copy of the report entitled EDR GeoCheckO- Physical Setting Source ; <br /> Addendum, dated January 27, 2004, is included as Appendix A Five water supply wells were <br /> identified down gradient of the site within a 1-mile radius of the site <br /> �t <br /> • EDR Well ID CA3900732 is located approximately 114 to 112-mile east-northeast and down <br /> gradient from the site This well is listed as a water well, <br /> • EDR Well ID 23104 is located approximately 1/4 to 112-mile northeast and down gradient <br /> from the site This well is listed as a water well, <br /> • EDR Well ID 219 is located approximately 114 to 112-mile northeast and down gradient from <br /> t <br /> the site This well is listed as a water well, <br /> k <br /> • EDR Well ID 234 is located approximately 112 to 1-mile east-southeast down and cross <br /> gradient from the site This well is listed as a water well, <br /> • EDR Well ID 216 is located approximately 112 to 1-mile east-southeast down and cross <br /> gradient from the site This well is listed as a water well <br /> 11Chevron1920331REPORTSICSMICSM 92033 (REV B) doc x <br />