• then only 2 samples will be taken and analyzed. <br /> Water <br /> The equipment used to withdraw water from the well will be 2 PVC <br /> bailers. One bailer will be used to purge the well and the other <br /> will be used to withdraw the sample. All equipment including the <br /> bailers, and bailing cord, and the water depth measuring devise <br /> must be decontaminated prior to entering any well. They will be <br /> decontaminated by washing with Tri-sodium phosphate detergent and <br /> water and thoroughly rinsing them with clean water. <br /> The depth to groundwater will be measured from the highest point <br /> on the top of the casing to the surface of the water table. The <br /> devise used will be an electric conductivity devise which trips a <br /> red light and a buzzer when the probe touches water. A minimum <br /> of three measurements will be made at each well , the final <br /> reading will be noted after 2 or more readings do not vary by <br /> more than 0 .03 feet. <br /> once the depth to water is known the tape and probe will be <br /> withdrawn from the well and thoroughly dried. A small amount of <br /> water paste will be placed on the axis of the probe and the probe <br /> will be lowered to the water table. Care will be taken to not <br /> allow the probe to descend into the water below the contact <br /> point. Then the probe will be withdrawn rapidly and inspected <br /> for signs of fluid above the contact point. If fluid is noted <br /> the is will be smelled to verify it as fuel, then the thickness <br /> of the fuel will be noted on the measuring log. Water samples <br /> will be obtained as follows: <br /> A) First one full well volume of water will be withdrawn from the <br /> well; <br /> B) The parameters of pH, Conductivity, and Temperature will be <br /> measured; <br /> C) A 2nd and 3rd well volume of water will be withdrawn and the <br /> parameters remeasured, if the results vary by more than log then <br /> step C is repeated; <br /> D) The well is allowed to recover to 80% of its original volume <br /> or 2 hours have passed then a sample will be withdrawn and placed <br /> in its appropriate container. <br /> Purged water will be placed in a drum sealed and left at the site <br /> until its hazardous condition is assessed. <br /> Each well location will be surveyed to within 0 . 5 Ft. <br /> horizontally and to within 0 . 01 Ft. vertically. The elevation to <br /> the top of the casing in each well will be measured with a spirit <br /> level and surveyors rod. The leveling will take place at least <br /> 24 hours after the casing seal and traffic box have been set. <br /> Page 6 <br />